Veichi SI23-D1 series Manual
Veichi SI23-D1 series Manual

Veichi SI23-D1 series Manual

Solar water pump inverter

Advertisement

Chapter 1 Safety Requirement and Cautions

To ensure safety of your health, equipment and property, please read this chapter carefully before using the frequency inverter
and act in compliance with the instructions when installing,ebugging, running and overhauling the frequency inverter.
1.1 Safety Definition
Danger: it will cause danger of serious injuries and even death while operating against the rules.
Caution: it will cause danger of light injuries or equipment destruction while operating against the rules.
Note: some information is useful while operating and use frequency inverter.
1.2 Safety Requirements and Cautions
●Before Installation
1. Only qualified personnel can operate the equipment. Before operating, be sure to carefully read the manual about safety,
installation, operation and maintenance. The safe operation depends on the proper processes of choosing models,
carrying, installation, operation and maintenance.
1. Don't use the damaged or incomplete frequency inverters; Otherwise, there is risk of injury.
●Installation
1. Please install the frequency inverter on metal or other nonflammable material, and keep it away from the combustible
material. Otherwise there is danger of fire;
2. No unauthorized modification to the frequency inverter; Otherwise there is danger of damaged.
3. Normal frequency inverter, which is not explosion-proof, can not be installed where with explosive gas or dust; Otherwise
there is danger of explosion.
1. When two frequency inverters are installed in the same control cabinet, pleas pay attention to the installing place to
guarantee the effective heat dissipation.
2. When carrying the frequency inverter, ease support its bottom.
●Wiring
1. Wire is connected only when the main circuit is cut off, otherwise there is a danger of shock.
2. Wire is connected by professional person only. Otherwise there is a danger of shock.
3. Earth must be reliable. Otherwise there is a danger of shock.
4. AC power supply should not be connected with output ports U, V, W, otherwise there is a danger of damage to frequency
SI23 Solar Pump Inverter Manual
Danger
Danger
Danger
Attention
Danger
1

Advertisement

Table of Contents
loading

Summary of Contents for Veichi SI23-D1 series

  • Page 1: Chapter 1 Safety Requirement And Cautions

    SI23 Solar Pump Inverter Manual Chapter 1 Safety Requirement and Cautions To ensure safety of your health, equipment and property, please read this chapter carefully before using the frequency inverter and act in compliance with the instructions when installing,ebugging, running and overhauling the frequency inverter. 1.1 Safety Definition Danger: it will cause danger of serious injuries and even death while operating against the rules.
  • Page 2 SI23 Solar Pump Inverter Manual inverter. 5. No drop of bolt, spacer, metal stick, conducting wire or other things into the inner of frequency inverter; Otherwise there is a danger of fire or damage to frequency inverter. Attention 1. If the damage to frequency inverter or other equipment is caused by improper wiring and utilization or unauthorized alteration, the user should shoulder all responsibilities.
  • Page 3: Operation

    SI23 Solar Pump Inverter Manual Attention 1. Please set the parameter of frequency inverter cautiously; Otherwise it will damage equipment. ●Operation Danger 1. Before running, please check and confirm the application range of the machine and equipment once more; Otherwise it will cause accidents.
  • Page 4: Technical Specification

    Voc voltage (V) current power voltage power(KW) voltage V (Hz) (KW) (KW) SI23-D1 series, DC60-400VDC input, 3 phase 110-230VAC output 0.75 0.75 175~380 0-600 1.95 175~380 0-600 SI23-D3 series,DC150V-450V input, 3 phase 220-240VAC output 0.75 0.75 360~430 0-600 1.95...
  • Page 5: Chapter 2 Installation And Wiring

    SI23 Solar Pump Inverter Manual Chapter 2 Installation and Wiring 2.1 Dimension of Inverter Overall Dimension of Inverter (Plastic) Installation Diameter Overall Dimension(mm) Installation Dimension(mm) Apertu MODEL SI23-D3-R75G ф3-M4 SI23-D3-1R5G SI23-D3-2R2G 231.5 ф3-M4 SI23-D3-004G SI23-D5-R75G SI23-D5-1R5G ф3-M4 SI23-D5-2R2G SI23-D5-004G 231.5 ф3-M4 SI23-D5-5R5G SI23-D5-7R5G...
  • Page 6 SI23 Solar Pump Inverter Manual Installation Diameter Overall Dimension(mm) Installation Dimension(mm) MODEL Aperture SI23-D5-015G SI23-D5-018G ф4-M5 SI23-D5-022G SI23-D5-030G 416.5 ф4-M5 SI23-T3-037G...
  • Page 7: Installation

    SI23 Solar Pump Inverter Manual Overall Dimension of Inverter (Steel) Installation Diameter Overall Dimension(mm) Installation MODEL Aperture SI23-T3-045G SI23-T3-055G ф4-M6 SI23-T3-075G...
  • Page 8: Standard Connection Diagram

    SI23 Solar Pump Inverter Manual 2.2 Solar Pump Controller Wiring ● Standard Connection Diagram DC POWER INPUT MCCB Contactor Input Rector Output Rector Shielded cable or armoured cable (the end close to VFD grounding) Note2 +24V (The grounding resistance is less than 10 ohms) Note:Function description in brackets is factory default AC220V...
  • Page 9: Chapter 3 Keyboard Layout And Functions Specification

    SI23 Solar Pump Inverter Manual Chapter 3 Keyboard layout and functions specification Keyboard Appearance ● Key function ● Name Function Enter menu while standby or running. Presses this key to return while modify Menu key parameter. While standby or running, press for 1 sec to enter condition monitoring interface.
  • Page 10: Chapter 4 Fault Diagnosis And Solution

    SI23 Solar Pump Inverter Manual Chapter 4 Fault Diagnosis and Solution This chapter describes the inverter fault, alerts, and operation of the failure on the inverter, the display information on inverter and countermeasures. Fault Information and Description in Detail Keypad Fault Fault type Possibility reason...
  • Page 11 SI23 Solar Pump Inverter Manual curve is not appropriate. ● Select rotational speed tracking ● The voltage is too low. restart or start the motor after it ●The startup operation is stops. performed on the rotating ● Remove the added load. motor.
  • Page 12 SI23 Solar Pump Inverter Manual ●AC drive selected is too load ●Deceleration is too short ● Prolong acceleration time ●Short circuit of solar drive ● To check peripheral equipment output or phase output short E. SC System abnormal ● Ask to support circuit to ground ●...
  • Page 13 SI23 Solar Pump Inverter Manual ●Electromagnetic disturb in ● Resume load and save. E.EEP Memory fault memory period. ● Seek support from factory. ● EEPROM damage. LIFE Reserved ●Check 3-phase power supply and ●3-phase input power open the phase. E.ILF Input phase loss phase.
  • Page 14: Chapter 5 Parameters List

    SI23 Solar Pump Inverter Manual Chapter 5 Parameters List This chapter just provides function parameter table. Specifications refer to AC300 technical manual or inquiry the company. “●”: Parameter can be changed in the running state. “〇”: Parameter can’t be changed in the running state. “×”: Parameter can be read only.
  • Page 15 SI23 Solar Pump Inverter Manual Binding LED“000”digit: communication command instruction binding LED“0000”digit: optional card command instruction binding 0 : no binding 1 : keyboard number given frequency 2 : Reserved 3 : Voltage/Current analog AI1 given 4 : Voltage/Current analog AI2 given 5 : Reserved 6 : Terminal pulse PUL given 7: RS485 communication given...
  • Page 16 SI23 Solar Pump Inverter Manual 0: Invalid 1: Valid LED“0000”digit: reserved G/P Model ● F00.17 0:G Type 1:P Type 0x011 Setting F00.18 Reserved 0: No action Parameter 1: Restore factory default (not restoring motor parameters) 〇 F00.19 0x013 initialization 2: Restore factory default (restoring motor parameters) 3: Clear malfunction records Operation Control Parameters Group Function description...
  • Page 17 SI23 Solar Pump Inverter Manual protection when abnormal exit LED “000” digit: Operate protection when command channel switch to terminal 0: Positive 1: Negative LED “0” digit: Terminal Y Output terminal polarity ● F02.42 LED “00” digit: Relay output 1 0000 0x22A selection...
  • Page 18 SI23 Solar Pump Inverter Manual 0: Non-keyboard control mode is invalid 1: Non-keyboard control mode stops according to 〇 F04.08 STOP key setting stop mode 0x408 2: Non-keyboard control mode stop according to free stop mode LED “0” digit: keyboard UN/DOWN key modify selection 0: Invalid 1: Modify frequency setting by key board numbers...
  • Page 19 SI23 Solar Pump Inverter Manual LED “0” digit: output frequency selection 0: Aim frequency Keyboard display item 1: Running frequency ● F04.22 0000 0x416 setting LED “000” digit: power display dimension 0: Power display percentage (%) 1: Power display kilowatt (KW) LED “0”...
  • Page 20 SI23 Solar Pump Inverter Manual Model ※ F05.02 Motor rated power 0.1~1000.0kW 0x502 Model ※ F05.03 Motor rated frequency 0.01~max frequency 0x503 ※ F05.04 Motor rated speed 1~65000rpm Model 0x504 ※ Model F05.05 Motor rated voltage 1~1500V 0x505 ※ F05.06 Motor rated current 0.1~3000.0A Model...
  • Page 21 SI23 Solar Pump Inverter Manual ● F06.00 ASR(speed loop) proportional gain 1 0.01~100.00 10.00 0x600 ● F06.01 ASR integral time 1 0.000~6.000s 0.200s 0x601 ● F06.02 ASR filter time1 0.0~100.0ms 0.0ms 0x602 ~ 0.00 ● F06.03 ASR switch frequency 1 0.00Hz 0x603 frequency...
  • Page 22 SI23 Solar Pump Inverter Manual ● F06.29 Motor weak magnetic feed forward gain 0.0~200.0% 10.0% 0x61E ● F06.30 Motor weak magnetic gain 0.0~500.0% 10.0% 0x620 ● F06.32 MTPA gain 0.0~500.0% 100.0% 0x621 ● F06.33 MTPA filter time 0.0~100.0ms 1.0ms 0x621 F06.34 Reserved ●...
  • Page 23 SI23 Solar Pump Inverter Manual Protection and Malfunction Parameter Group Factory Function description Range of settings and definition Feature Address default LED”0” digit: Over voltage suppression 0: Invalid 1: Valid in DEC Bus over voltage 2: Valid both in ACC/DEC 〇...
  • Page 24 SI23 Solar Pump Inverter Manual LED “0” digit: Modbus main-slave selection Main-slave machine 〇 F13.00 0: Slave machine 0000 0xD00 selection 1: Main machine LED “00” /“000”/”0000”digit: reserved 485 communication 〇 F13.01 1~247 0xD01 address LED“0” digit:485 communication 0:1200 bps 1:2400 bps Communication baud 〇...
  • Page 25 SI23 Solar Pump Inverter Manual 10.0% Frequency (AM) ● F14.06 0.1~500.0% 0xE06 adjusting gain 40.0% (PMSM) MPPT search ● F14.07 0.1~100.0 1.0s 0xE07 interval MPPT regulating ● F14.08 0~9999 0xE08 gain Quick-drop ● F14.09 0~20 0xE09 frequency gain Frequency ● F14.10 0.001~2.000 s 0.001...
  • Page 26 SI23 Solar Pump Inverter Manual Input minimum ● F14.23 power protection 0.00~650.00kw 0.00kw 0xE17 power point setting Minimum power ● F14.24 protection detect 0.0~3000.0s 10.0s 0xE18 time Minimum power protection auto ● F14.25 0.0~3000.0s 10.0s 0xE19 restore working time 0:Auto reset;1:Reset by manual LED0:Low speed protection Fault alarm restore ●...
  • Page 27 SI23 Solar Pump Inverter Manual Power per day/ generated power ● F14.44 0.0~24.0h 7.0h 0xE32 per day reset period F14.45 Reserved 0:Invalid 1:Valid LED0:Constant torque frequency limit Photovoltaic pump selection ● F14.46 1100H 0xE34 function selection 1 LED1:Reserved LED2:Voltage rising update Voc voltage LED3: Fast frequency falling function Fast frequency...
  • Page 28 SI23 Solar Pump Inverter Manual Read C02.32 Voc voltage 0.1 V 2320H only Read C02.33 Flow per day 0.1 m3 2321H only Cumulative Read C02.34 total flow(low 0.1m3 2322H only position) Cumulative Read C02.35 total flow(high 0.1km3 2323H only position) Generated Read C02.36...
  • Page 29: Chapter 6 Operation Guidance

    SI23 Solar Pump Inverter Manual Chapter 6 Operation Guidance 6.1 Asynchronous Motor Pump Drive Operation Guidance 1) Wiring: a. Confirmed the solar pump drive if mating with motor. b. Correctly connecting “+”“-” of solar panel to corresponding “+”“-” pole of inverter or R, T wiring terminals. Otherwise it will cause inverter damage.
  • Page 30: Common Problems And Solutions

    SI23 Solar Pump Inverter Manual 3) Common problems and solutions a, Q:Well-lit conditions, the pump is running, but the water is very small. A:Check if the pump motor direction is reversed. b, Q:Well-lit conditions, the drive is in standby mode 0.00Hz. A:Check F14.01, observe what protection status is the drive in currently, check whether the parameters set is reasonable.
  • Page 31 SI23 Solar Pump Inverter Manual recovery)time, automatically resume to running state. F. Full Water Protection Detect the water full alarm and low water level through two X terminals, realizing automatic level control. Wherein F14.27 is the water overfill protection detection time and F14.28 is full water protection exit time, and X 3 terminal is defined as full solar water detection alarm, and X4 terminal is defined as full solar water detection alarm reset, the warning signal is shown as "A.Ful".