Parameter details
Code (Addr.)
Name
F11.10
Status interface left
(0x0B0A)
shift, right shift key
STOP
function selection
Unit digit: Left shift key to adjust the first line of monitoring
Ten digits: Right shift key to adjust the second line of monitoring
Note:
The current loop parameter is displayed when invalid, and the loop parameter 1 is displayed after power-on.
When the left/right shift key function selection is invalid, press the left/right shift key, the monitor will not switch; the left/right shift key function
selection will be changed to valid, and the monitoring quantity will change immediately.
F11.11: The first line of the keyboard shows the parameter 1
Code (Addr.)
Name
F11.11
The first line of the
(0x0B0B)
keyboard shows the
RUN
parameter 1
F11.12: The first line of the keyboard shows the parameter 2
Code (Addr.)
Name
F11.12
The first line of the
(0x0B0C)
keyboard shows the
RUN
parameter 2
Code (Addr.)
Name
F11.13
The first line of the
(0x0B0D)
keyboard shows the
RUN
parameter 3
Code (Addr.)
Name
F11.14
The first line of the
(0x0B0E)
keyboard shows the
RUN
parameter 4
Code (Addr.)
Name
F11.15
The second line of the
(0x0B0F)
keyboard shows the
RUN
parameter 1
Code (Addr.)
Name
F11.16
The second line of the
(0x0B10)
keyboard shows the
RUN
parameter 2
Code (Addr.)
Name
F11.17
The second line of the
(0x0B11)
keyboard shows the
RUN
parameter 3
Code (Addr.)
Name
F11.18
The second line of the
(0x0B12)
keyboard shows the
RUN
parameter 4
Keyboard display parameters: used to set the contents of the single-line keyboard and double-line keyboard display parameters.
AC10 Series Frequency Inverter Technical Manual
Content
V/F SVC
0: Invalid, 1: Valid
0: Invalid, 1: Valid
Content
V/F SVC
Used to set the contents of single-line keyboard and double-line keyboard
display parameters
Content
V/F SVC
Used to set the contents of single-line keyboard and double-line keyboard
display parameters
Content
V/F SVC
Used to set the contents of single-line keyboard and double-line keyboard
display parameters
Content
V/F SVC
Used to set the contents of single-line keyboard and double-line keyboard
display parameters
Content
V/F SVC
Used to set the contents of the two-line keyboard display parameters
keyboard shows the parameter 2
Content
V/F SVC
Used to set the contents of the two-line keyboard display parameters
Content
V/F SVC
Used to set the contents of the two-line keyboard display parameters
Content
V/F SVC
Used to set the contents of the two-line keyboard display parameters
170
Factory setting
(Setting range)
0011
(0000~0011)
Factory setting
(Setting range)
0000
(0000~0763)
Factory setting
(Setting range)
0001
(0000~0763)
Factory setting
(Setting range)
0000
(0000~0763)
Factory setting
(Setting range)
0000
(0000~0763)
Factory setting
(Setting range)
0002
(0000~0763)
Factory setting
(Setting range)
0004
(0000~0763)
Factory setting
(Setting range)
0010
(0000~0763)
Factory setting
(Setting range)
0012
(0000~0763)