How to conduct motor self-tuning
When the motor is running, the motor related parameters are automatically learned and set.
⇒ Section 4.8 Auto-tuning
How to diagnose faults
When a warning or fault is displayed on the keyboard
⇒ Section 6.2 Fault, warning, prompt code type
When no alarm or fault is displayed on the keyboard
⇒ Section 6.7 Troubleshooting without prompting on the keyboard
How to choose
Drive model and nameplate
⇒ Section 2.2 Drive model and nameplate
Installation size
⇒ Section 3.4 Dimensions
Parameter profile
⇒ Chapter 10 Parameter List
Detailed description of the parameters
⇒ Chapter 11 Parameter Details
I
AC10 Series Frequency Inverter Technical Manual

Advertisement

loading

Summary of Contents for Veichi AC10 Series

  • Page 1 Drive model and nameplate ⇒ Section 2.2 Drive model and nameplate Installation size ⇒ Section 3.4 Dimensions Parameter profile ⇒ Chapter 10 Parameter List Detailed description of the parameters ⇒ Chapter 11 Parameter Details AC10 Series Frequency Inverter Technical Manual...
  • Page 2 8.2 Precautions related to scrapping ..............................54 Peripheral Equipments and Options ..............................55 9.1 Safety Precautions ................................... 55 9.2 Peripheral Equipments ..................................55 9.3 The use of peripheral equipments ..............................56 Function Table ..................................... 59 10.1 Safety Precautions ..................................59 AC10 Series Frequency Inverter Technical Manual...
  • Page 3 11.13 F11 Group: keyboard parameters ............................... 168 11.14 F12 Group: Communication parameters ............................ 172 11.15 F13 Group: Process PID Control ..............................175 11.16 F14 Group: multi-speed and simple PLC ........................... 181 Revised record ......................................187 AC10 Series Frequency Inverter Technical Manual...
  • Page 5 1.2 Safety Instructions Thank you for purchasing the AC10 series vector control drive designed and manufactured by Flextronics. This manual describes how to use this product correctly for good returns. Please read this manual carefully before using the product (installation, wiring, operation, maintenance, inspection, etc.). In addition, please use this product after fully understanding the safety precautions described in this manual.
  • Page 6 Please follow the local standards and set the bypass protection circuit. Improper wiring may result in fire or personal accident. NOTE In order to prevent injuries Do not carry the drive with the front cover or terminal cover of the drive. In addition, please confirm that the screws are properly tightened before handling. AC10 Series Frequency Inverter Technical Manual...
  • Page 7 If you need to use this product for special purposes such as manned mobile, medical, aerospace, nuclear power, electric power, submarine relay communication equipment or systems, please contact our agent or sales person in charge. AC10 Series Frequency Inverter Technical Manual...
  • Page 8 • If you find that the product is in bad condition, please contact the agent of the company where you purchased the product or the person in charge of the company VFD model Input speci. Output speci.1 Output speci.2 Produce No. Model reference AC10 Series Frequency Inverter Technical Manual...
  • Page 9 Automatic energy Automatically optimize output voltage according to load under V/F control mode to achieve energy- saving operation saving operation Automatic current Automatically limit current during operation to prevent frequent overcurrent fault trips limiting AC10 Series Frequency Inverter Technical Manual...
  • Page 10 R, S, T. 2.4 Drive rated output current Voltage 220V 380V Power(KW) Rated output current (A) —— 0.75 —— —— —— 11.0 —— 15.0 —— 18.5 —— 22.0 —— AC10 Series Frequency Inverter Technical Manual...
  • Page 11 In the open loop control, the drive can only drive one motor; and the drive capacity and motor capacity can not be too different, the drive can be two  or smaller than the motor's power level, otherwise the control performance may be degraded. , or the drive system is not working properly. AC10 Series Frequency Inverter Technical Manual...
  • Page 12 Table 3-1: Environmental conditions required for reliable operation of AC10 series drives ● In order to improve the product stability, please do not use the drive where temperature changes sharply. While using in closed space such as control cabinet, please use cooling fan or air-conditioning to cool drive to avoid temperature over limit range.
  • Page 13 Installation and Wiring Output current(%) Temperature (°C) Chart 3-2:AC10 series drive derating curve while over permit temperature ● Derate according to the chart while over altitude limit. PERMIT OUTPUT CURRENT(%) 1000 2000 3000 4000 ALTITUDE(M ) Chart 3-3:AC10 series drive derating curve while over permit altitude 3.3 Installation Direction and Space...
  • Page 14 Installation and Wiring 3.4 Dimensions Drive dimensions 安装孔径 Mounting aperture Forward mounting size Dimensions(mm) Side mounting size (mm) (mm) Mounting Drive Model aperture AC10-T/S2-R04G-B 3-M4 AC10-T/S2-R75G-B AC10-T/S2-1R5G-B 3-M4 AC10-T/S2-2R2G-B AC10-T3-R75G-B 3-M4 AC10-T3-1R5G-B AC10-T3-2R2G-B AC10-T3-004G-B 3-M4 AC10-T3-5R5G-B AC10 Series Frequency Inverter Technical Manual...
  • Page 15 安装孔径 7.5kW-22kW Installation Dimension Drawing Forward mounting size Dimensions(mm) Side mounting size (mm) Mounting (mm) Drive Model aperture AC10-T3-7R5G-B 12.5 一 一 一 AC10-T3-011G-B AC10-T3-015G-B 342.5 303.5 12.5 326.5 一 一 一 AC10-T3-018G-B AC10-T3-022G-B AC10 Series Frequency Inverter Technical Manual...
  • Page 16 External lead double row keyboard pocket shape and opening size drawing  External lead single line keyboard shape and opening dimensions Model:KBD10-15 (Note: Mounting plate opening size: 61mmx36mm.(Unit in the picture: mm)) 26.6 35.6 60.6 38.3 参考开孔尺寸:61x36mm AC10 Series Frequency Inverter Technical Manual...
  • Page 17 ● Control cable, power cable and motor cable must be separated. They can not be in the same cable trough or cable rack. ● This equipment can only be used as the maker states. Please consult Veichi while using in special case. ● No insulation test for the drive or the related cable by HV insulation test equipment.
  • Page 18 5. For 0.4kW to 5.5kW drives, the COM and GND terminals are two-in-one function terminals and are combined externally as GND terminals; for 7.5kW to 22kW drives, both COM and GND terminals are available. AC10 Series Frequency Inverter Technical Manual...
  • Page 19 24V auxiliary power supply output, constitutes loop with COM. 100mA Collector open circuit output, can set the action-object by DC24V/50mA program. TA/TB/TC Passive connector output, can set the action-object by program. 3A/240VAC Function Specification of Switch Terminals AC10 Series Frequency Inverter Technical Manual...
  • Page 20 Turn off AO current output RS485 communication access 120Ω termination resistor RS485 communication disconnect 120Ω termination resistor Control board grounding Control board not grounded 7.5kW-22kW dipswitch description More details: Connection diagram of jumper caps "+24V", "PLC", "COM" AC10 Series Frequency Inverter Technical Manual...
  • Page 21 3.6 Main Circuit Wiring Main circuit terminal arrangement and definition 0.4kW-5.5kW Terminal arrangement 7.5kW-22kW Terminal arrangement Table 3-3: Main Circuit Terminal Arrangement and Definition of AC10 Series Drives Terminal symbol Terminal name Terminal function definition DC power output, (-) for DC bus negative, (+) for DC bus positive, terminal DC power terminal block for 7.5kW-22kW models.
  • Page 22 AC10-T3-5R5G-B ------ NFI-020 NFO-020 ------ NFI-020 NFO-020 AC10-T3-7R5G-B ------ NFI-036 NFO-036 AC10-T3-011G-B ------ NFI-036 NFO-036 AC10-T3-015G-B ------ NFI-050 NFO-050 AC10-T3-018G-B ------ NFI-050 NFO-050 AC10-T3-022G-B Model Contactor specifications Circuit breaker specifications AC10-T/S2-R40G-B AC10-T/S2-R75G-B AC10-T/S2-1R5G-B AC10-T/S2-2R2G-B AC10 Series Frequency Inverter Technical Manual...
  • Page 23 0.4kW-5.5kW Control circuit terminal arrangement AI AO A+ X1 X2 TA TB TC B- X3 X4 COM Y 24V 7.5kW-22kW Control circuit terminal arrangement Table 3-7: AC10 series drive control circuit terminal arrangement and definition AC10 Series Frequency Inverter Technical Manual...
  • Page 24 Twisted pair shielded A+ B- M2.5 0.75 0.4~0.6 cable Twisted pair shielded +10V GND AO AI M2.5 0.75 0.4~0.6 cable +24V GND Y TA TB TC X1 X2 X3 X4 M2.5 0.4~0.6 0.75 Shielded cable AC10 Series Frequency Inverter Technical Manual...
  • Page 25 Build-in braking unit max braking performance Braking unit of AC10 series product with low power can be selected according to the suggested braking resistance specification parameters in table above. In large inertia or long time frequent brake occasion, the moment maybe should be increased. The max braking power is showed in the following table, the range of which can not be over in use.
  • Page 26 Chart 3-11: Standby control system of power supply directly driving model AC10 Series Frequency Inverter Technical Manual...
  • Page 27 When the run/stop is controlled by the keyboard, press this button to turn the drive forward. The status indicator is always on during forward run, and the status indicator is flashing during reverse run. AC10 Series Frequency Inverter Technical Manual...
  • Page 28 Set key: After modifying the value, press this key to confirm the modified value. Left/Right shift Move left and right operation bits Jog/Reverse Select the function of the key by parameter [F11.02], 0: reverse 1: jog ● Number word comparison table AC10 Series Frequency Inverter Technical Manual...
  • Page 29 The following is the basic initial startup procedure of our drive. For the first time, please refer to the corresponding flow chart according to the actual situation for use; here only the most basic settings are introduced, and the user can operate according to this step; AC10 Series Frequency Inverter Technical Manual...
  • Page 30 Choose VF control or vector control according to your needs Set the running frequency given channel F01.01 Set the operating frequency reference channel F01.02/F01.04 Press the RUN button Press STOP/RESET button to stop End of trial run AC10 Series Frequency Inverter Technical Manual...
  • Page 31 Press the RUN button to start auto-tuning Self-tuning failed, motor parameters are error occurs not updated Check the cause of the fault and Press the keyboard RUN re-tune after button troubleshooting End of trial running AC10 Series Frequency Inverter Technical Manual...
  • Page 32 Make sure that the wiring of the drive output terminals (U, V, W) and the motor terminals are terminal reasonable and correct. Control circuit terminal wiring Confirm that the control circuit terminal wiring of the drive is reasonable and correct. AC10 Series Frequency Inverter Technical Manual...
  • Page 33 (Note) Stop-type self-tuning is an alternative function when rotary self-tuning cannot be implemented. Therefore, sometimes the measurement result of the self-tuning becomes larger than the error of the motor characteristic. After the stop type self-tuning is completed, confirm the measured motor characteristic value by parameter. AC10 Series Frequency Inverter Technical Manual...
  • Page 34 Example: 5 Hz → 10 Hz → 20 Hz → 30 Hz → 40 Hz → 50 Hz 7. After confirming that the motor can rotate normally, press the STOP button, the running indicator will go out after the motor is completely stopped. AC10 Series Frequency Inverter Technical Manual...
  • Page 35 An overvoltage fault occurs at F03.04 [Speed loop filter time 1] • When overvoltage occurs, confirm the 0.00s the end of acceleration, at the F03.08 [speed loop filter time 2] responsiveness and gradually increase the set AC10 Series Frequency Inverter Technical Manual...
  • Page 36 The AC10 series drives are equipped with RS485 communication interface and the master-slave communication using the international standard Modbus communication protocol. The user can realize centralized control through PC / PLC, host computer, main station drive, etc. (set drive control command, running frequency, modification of related function code parameters, drive working status and fault information monitoring, etc.) to adapt Specific application...
  • Page 37 Protocol Modbus protocol (RTU only (mode) Note: The AC10 series only supports RTU mode. 5.2.3 Information format In RTU mode, a new frame begins with a transmission time pause interval of at least 3.5 bytes. The data fields transmitted next are: slave address, operation command code, data and check word, the transmission of the last byte is completed, and the end of the frame is indicated by a transmission time interval of at least 3.5 bytes.
  • Page 38 3.5 bytes of transmission time Slave address Command code Write data address high Write data address low High data content Low data content CRC CHK low CRC CHK high 3.5 bytes of transmission time AC10 Series Frequency Inverter Technical Manual...
  • Page 39 3.5 bytes of transmission time 5.2.5 Communication data list AC10 series function parameter address representation rules: The drive function parameter number is the register address, which is divided into two parts: high byte and low byte. The high byte indicates the group number of the function parameter, and the low byte indicates the serial number of the function parameter, which needs to be converted into hexadecimal.
  • Page 40 0 is the faultless code. 0.0% 0x2011 Torque current component Belt special machine application parameters (0.0~400.0%) /0x3011 0x2012 0.000s Torque filtering time Read and write the value of F03.47 /0x3012 (0.000~6.000s) 0x2013 Reserved Use with optional card /0x3013 AC10 Series Frequency Inverter Technical Manual...
  • Page 41 DC voltage of the main circuit has dropped to Safety level, wait 5 minutes before performing related work. AC10 Series Frequency Inverter Technical Manual...
  • Page 42 Over-voltage during deceleration Fault E.OU2(10) Over-voltage at constant speed Fault E.OU3(11) Under-voltage in operation Fault E.LU(13) Motor overload Fault E.OL1(14) Drive overload 1 Fault E.OL2(15) Drive overload 2 CBC continues to generate Fault E.OL3(16) AC10 Series Frequency Inverter Technical Manual...
  • Page 43 E.LD2(80) CPU timeout failure Fault E.CPU(81) Chip lock Fault E.LOC(85) Parameter storage failure Fault E.EEP(86) Expansion card A disconnected Fault E.BUS1(91) Expansion card B is disconnected Fault E.BUS2(92) CAN expansion card failure Fault E.BUS3(93) AC10 Series Frequency Inverter Technical Manual...
  • Page 44 Note: All faults must be reset by a fault reset operation. Code Name Reason Countermeasures E.SC1 Accelerated system Short circuit on the output side of the drive or short Check the main circuit to eliminate the short circuit AC10 Series Frequency Inverter Technical Manual...
  • Page 45 Short circuit on the output side of the drive or short during deceleration Check the main circuit to eliminate the short circuit circuit to ground Measure the resistance between the motor wires and Motor damage replace the motor immediately if it is turned on. AC10 Series Frequency Inverter Technical Manual...
  • Page 46 Name Reason Countermeasures Reduce the load Excessive load Appropriate increase of motor overload protection curve Motor E.OL1 overload coefficient Whether the acceleration and deceleration time settings are Increase F01.22, F01.23 [addition and deceleration time] AC10 Series Frequency Inverter Technical Manual...
  • Page 47 Check if the motor W connection line is normal W phase output of the drive Check if the drive output terminal screw is loose E.OLF3 phase loss Motor damage Measure the resistance between the motor wires and replace the motor AC10 Series Frequency Inverter Technical Manual...
  • Page 48 Confirm that the PID feedback wiring is normal. disconnection fault Sensor for PID feedback fails Check if the sensor is abnormal The PID feedback loop of the drive control board is Seek technical support from manufacturers AC10 Series Frequency Inverter Technical Manual...
  • Page 49 F10.42 [speed deviation detection time]. This fault detection can be enabled by F10.40 [Speed deviation excessive protection action] and the motor operation mode when the fault is detected can be set. AC10 Series Frequency Inverter Technical Manual...
  • Page 50 When the warning occurs, the drive can continue to operate. The following table explains the cause of the failure and the corresponding measures. Note: All warnings can be automatically eliminated if they do not meet the detection conditions. Code Name Reason Countermeasures AC10 Series Frequency Inverter Technical Manual...
  • Page 51 Check if the communication connection is normal disconnection, etc. Modbus communication A.CE Check whether the grounding wire of the whole warning Communication data is abnormal due to interference machine is normal. Change the communication cable with shield AC10 Series Frequency Inverter Technical Manual...
  • Page 52 Note: The motor operation mode when the fault is detected can be set by F06.59 [Comparator 2 Alarm Setting]. 6.6 Fault reset method When the drive has a fault and stops running, please follow the steps below to find out the cause and restart the drive after taking appropriate countermeasures. AC10 Series Frequency Inverter Technical Manual...
  • Page 53 Cleaning the fan of the motor fan to stall or stop. Improve the cleanliness of the environment  Do not run according to the set acceleration/deceleration time Reason Countermeasures Excessive load Reduce the load AC10 Series Frequency Inverter Technical Manual...
  • Page 54 Do not allow inflammables to come into contact with the drive or attach flammable materials to the drive. Install the drive on a flame retardant object such as metal. Otherwise there is a risk of fire. AC10 Series Frequency Inverter Technical Manual...
  • Page 55 If it cannot be repaired, the entire drive needs to be Is there any damage, deformation, or abnormal operation replaced. of the device? Repair or replace the wires. Whether the wires and their joints are discolored, wiring damaged, or cracked. AC10 Series Frequency Inverter Technical Manual...
  • Page 56 8) The tightening torque of each terminal is different. Please tighten the screws according to the specified tightening torque. 9) Use tools such as a torque wrench that matches the screw. Wiring the screw terminals requires a flat or hexagonal tool. Please refer to the recommended AC10 Series Frequency Inverter Technical Manual...
  • Page 57 Please confirm the steering under the no-load of the motor. The wrong direction of rotation may cause personal injury or property damage. Do not run a machine that has been damaged. If the machine is obviously damaged or parts are missing, do not connect or operate it to avoid an accident. AC10 Series Frequency Inverter Technical Manual...
  • Page 58 1) Drive body 2) Packaging materials 3) Expansion card Attention: In order to prevent injury, it will be properly scrapped after being discharged. So as not to cause a safety accident. AC10 Series Frequency Inverter Technical Manual...
  • Page 59 Passive energy consume unit of electric braking. Electric braking control unit, controlling the braking resistance consume the regenerated electric Consumption braking unit power of the motor efficiently. Output side noise filter Reduce the output side wire electromagnetic disturbance. AC10 Series Frequency Inverter Technical Manual...
  • Page 60 DC rector AC rector ⑩ Earthing Heat relay Control sysytem standby Chart 9-1: Peripheral equipments connetion Note: Wiring breaker To ensure wiring safe, protect power system and prevent malfunction impact other equipment AC10 Series Frequency Inverter Technical Manual...
  • Page 61 In normal case, the heat relay is suitable for the universal motor. While using the frequency drive to run the universal motor (standard motor), the motor current is 5-10% higher, comparing with the commercial power supply. Besides, at low speed, even in the motor rated current range, the cooling capability AC10 Series Frequency Inverter Technical Manual...
  • Page 62 While the motor cable is longer and the carrier frequency is higher, impacted by the leakage current, the heat relay maybe malfunction. To avoid it, please reduce the carrier frequency or set higher detection value of the heat relay. Before enhance the detection value, do confirm whether there is other cause for the motor overheat. Otherwise, there is danger. AC10 Series Frequency Inverter Technical Manual...
  • Page 63 Parameter [F 11.30] sets RS485/external keyboard to choose one. This parameter is not restored with [F00.03] parameter. Users are strongly advised to unlock the hardware connection of another channel when using one of them. AC10 Series Frequency Inverter Technical Manual...
  • Page 64 PID feedback disconnection judgment F13.29-F13.33 Sleep function F14.00-F14.14 Multi-speed frequency given F14.15 PLC operation mode selection F14 group multi-speed and simple PLC F14.16-F14.30 PLC running time selection PLC direction and acceleration and deceleration time F14.31-F14.45 selection AC10 Series Frequency Inverter Technical Manual...
  • Page 65 LED "0" and “00” digit: yy setting in function parameter number Fxx.yy (0x0010 Common parameter 0102 00~99 0x0027) address setting (0000 ~ 2363) LED "000" and "0000": Function parameter number Fxx.yy in xx setting 00~31 AC10 Series Frequency Inverter Technical Manual...
  • Page 66 (0x0107) 1: Channel B source selection (0 ~ 5) 2: Channel A + Channel B. 3: Channel A-channel B 4: Channel A, channel B both maximum 5: Channel A, channel B, both minimum AC10 Series Frequency Inverter Technical Manual...
  • Page 67 V/F SVC F01.20 Set the reference frequency to calculate the acceleration/deceleration time. Acceleration/deceleration time (0x0114) 0: Maximum frequency reference frequency (0 ~ 2) STOP 1: Fixed frequency 50Hz 2: Set the frequency AC10 Series Frequency Inverter Technical Manual...
  • Page 68 F01.4x group: PWM control Parameter (address) Factory default Name Content djustable (setting range) attribute F01.40 V/F SVC 4.0 kHz (0x0128) Carrier frequency Used to set the switching frequency of the drive IGBT. (1.0~16.0kHz) AC10 Series Frequency Inverter Technical Manual...
  • Page 69 Set the size of the asynchronous motor rotor resistance. (0.01mΩ~60000mΩ) STOP F02.13 Asynchronous motor stator V/F SVC Model setting (0x020D) leakage inductance Set the stator leakage inductance of the asynchronous motor. (0.01mH~ 65535mH) STOP AC10 Series Frequency Inverter Technical Manual...
  • Page 70 Set the ASR (speed loop) integration time 2. (0.000~6.000s) F03.08 0.0ms (0x0308) ASR filtering time 2 Set the ASR filter time 2. (0.0~100.0ms) F03.09 0.00Hz ASR switching frequency 2 (0x0309) Set the ASR switching frequency 2. (0.00~Max frequency) AC10 Series Frequency Inverter Technical Manual...
  • Page 71 Set the weak magnetic voltage coefficient. (0.0 ~ 120.0%) F03.34 250.0% (0x0322) Output power limit Set the output power limit. (0.0 ~ 400.0%) F03.35 100.0% (0x0323) Overexcitation braking gain Set the overexcitation braking gain. (0.0 ~ 500.0%) AC10 Series Frequency Inverter Technical Manual...
  • Page 72 2: AI × F03.56; Torque control forward speed limit (0x0336) 3: Reserved; selection (0 ~ 7) 4: Reserved 5: PUL × F03.56; 6: RS485 communication given × F03.56 7: Reserved F03.55 Torque control reverse speed limit AC10 Series Frequency Inverter Technical Manual...
  • Page 73 Set the oscillation suppression filter time. F04.08 100.0% (0x0408) Output voltage percentage Set the output voltage percentage. (25.0~120.0%) STOP F04.1x group: Custom V/F curve Parameter (address) Factory default Name Content djustable (setting range) attribute AC10 Series Frequency Inverter Technical Manual...
  • Page 74 Terminal X1 function selection See the function of terminal X for details. (0 ~ 63) STOP F05.01 V/F SVC (0x0501) Terminal X2 function selection See the function of terminal X for details. (0 ~ 63) STOP AC10 Series Frequency Inverter Technical Manual...
  • Page 75 0: Closed valid 1: Disconnected is valid F05.22 X1 ~ X4 terminal characteristics LED "0" digit: X1 terminal 0000 (0x0516) selection LED "00" digit: X2 terminal (0000 ~ 1111) LED "000" digit: X3 Terminal LED "0000" digit: X4 Terminal AC10 Series Frequency Inverter Technical Manual...
  • Page 76 0: Straight line (default) 1: Curve 1 F05.43 2: Curve 2 0000 (0x052B) Analog input curve selection LED "0" digit: AI (0000~2222) LED "00" digit: Reserved LED "000" digit: Reserved LED "0000" digit: Reserved AC10 Series Frequency Inverter Technical Manual...
  • Page 77 Curve 2 lower limit corresponding V/F SVC 0.0% (0x0547) setting Corresponding set percentage (0.0~100.0%) F05.72 V/F SVC 30.0% (0x0548) Curve 2 inflection point 1 input voltage Set curve 2 inflection point 1 input voltage (0.0~100.0%) AC10 Series Frequency Inverter Technical Manual...
  • Page 78 0: 0~10V F06.00 1: 4.00~20.00mA (0x0600) AO output mode selection 2: 0.00~20.00mA (0 ~ 4) 3: FM high-speed pulse output Note: 5.5kW and below power models do not support high-speed pulse output, selected invalid AC10 Series Frequency Inverter Technical Manual...
  • Page 79 0.010s (0x061D) Y output OFF delay time Set the Y output OFF delay time. (0.000~60.000s) F06.30 V/F SVC 0.010s (0x061E) Relay 1 output OFF delay time Set relay 1 output OFF delay time. (0.000~60.000s) AC10 Series Frequency Inverter Technical Manual...
  • Page 80 00~07 F06.56 (0x0638) Comparator 2 upper limit V/F SVC (0 ~ 65535) F06.57 (0x0639) Comparator 2 lower limit V/F SVC (0 ~ 65535) F06.58 (0x063A) Comparator 2 bias V/F SVC (0 ~ 1000) AC10 Series Frequency Inverter Technical Manual...
  • Page 81 (0.000~60.000s) F06.73 0.010s (0x0649) vY4 output ON delay time V/F SVC (0.000~60.000s) F06.74 0.010s (0x064A) vY1 output OFF delay time V/F SVC (0.000~60.000s) F06.75 0.010s (0x064B) vY2 output OFF delay time V/F SVC (0.000~60.000s) AC10 Series Frequency Inverter Technical Manual...
  • Page 82 Power failure restart waiting time V/F SVC (0.00~60.00s) STOP F07.1x group: Shutdown control Parameter (address) Factory default Name Content djustable (setting range) attribute F07.10 V/F SVC (0x070A) Stop mode 0: Deceleration stop (0 ~ 1) 1: Free stop AC10 Series Frequency Inverter Technical Manual...
  • Page 83 F07.27 1.00s Speed tracking stop delay V/F SVC (0x071B) (0.0~60.0s) STOP F07.28 120.0% (0x071C) Speed tracking current V/F SVC (0.0~400.0%) STOP F07.3x group: Jog Parameter (address) Factory default Name Content djustable (setting range) attribute AC10 Series Frequency Inverter Technical Manual...
  • Page 84 (setting range) attribute V/F SVC F08.00 0: normal X terminal (0x0800) Counter input source 1: input terminal PUL (0 ~ 5) 2~5: Reserved F08.01 (0x0801) Count input crossover V/F SVC (0 ~ 6000) AC10 Series Frequency Inverter Technical Manual...
  • Page 85 V/F SVC (0.0~50.0%) STOP F08.35 10.0% (0x0823) Kick frequency V/F SVC (0.0~50.0%) STOP F08.36 5.00s (0x0824) Triangle wave rise time V/F SVC (0.1~999.9s) STOP F08.37 5.00s (0x0825) Triangle wave fall time V/F SVC (0.0~100.0s) STOP AC10 Series Frequency Inverter Technical Manual...
  • Page 86 (T3: 650 ~760 point: 820V (0x0A0C) Bus overvoltage suppression point Set bus voltage value for trigger overvoltage S2: 340 ~380) (750 ~840) STOP suppression function Also subject S2 overvoltage to overvoltage point: 400V limit (360 ~410) AC10 Series Frequency Inverter Technical Manual...
  • Page 87 2: Turn on, detect input missing phase report fault E.ILF, free stop F10.21 V/F SVC (0x0A15) Input phase loss threshold Set the percentage of voltage detection of the input phase loss (0 ~30.0%) STOP detection function, 100% corresponds to the rated bus voltage AC10 Series Frequency Inverter Technical Manual...
  • Page 88 Set the duration of the detected load warning 1 and the load is 5.0s (0x0A22) Load warning detection time 1 greater than the load warning detection level for the duration, and (0 ~60.0) STOP the load warning is detected. AC10 Series Frequency Inverter Technical Manual...
  • Page 89 (setting range) attribute V/F SVC F10.50 Set the number of fault self-recovery that is allowed to be (0x0A32) Failure self-recovery performed. (0 ~10) STOP Note: A value of 0 indicates that the fault self-recovery function AC10 Series Frequency Inverter Technical Manual...
  • Page 90 LED "0" and "00" digit: yy setting in function parameter number F11.05 Up and down keys to quickly Fxx.yy 0109 (0x0B05) change the parameter code 00~99 (0000 ~ 1563) setting LED "000" and "0000" digit: xx setting in function parameter number Fxx.yy 00~15 AC10 Series Frequency Inverter Technical Manual...
  • Page 91 LED "0" and "00" digit: Monitor parameter number Cxx.yy YY setting F11.16 Parameter 2 showed up on 00~63 0004 (0x0B10) second line of the keyboard LED "000" and "0000" digit: Monitoring parameter number Cxx.yy XX (0000 ~ 0763) setting 00~07 AC10 Series Frequency Inverter Technical Manual...
  • Page 92 1: External keyboard (0x0B1E) selection The terminal 485 bus and the external keyboard function are selected (0 ~ 1) STOP one by one. When the external keyboard is selected, the 485 bus (master/slave) cannot be used. AC10 Series Frequency Inverter Technical Manual...
  • Page 93 (0 ~ 1) 1: The writeing operation has no response F12.05 Modbus communication response (0x0C05) V/F SVC delay (0 ~ 500ms) F12.06 Modbus communication timeout 1.0s V/F SVC (0x0C06) failure time (0.1 ~ 100s) AC10 Series Frequency Inverter Technical Manual...
  • Page 94 F13.00 3: Reserved (0x0D00) PID controller given signal source 4: Reserved (0 ~ 9) 5: Terminal pulse PUL given 6: RS485 communication given 7: Option card 8: Terminal selection 9: Communication given active current AC10 Series Frequency Inverter Technical Manual...
  • Page 95 Integration time I2 V/F SVC (0.0~600.0s) F13.16 0.000s (0x0D10) Differential gain D2 V/F SVC (0.000~6.000s) F13.17 V/F SVC parameter switching (0x0D11) 0: Do not switch condition (0 ~ 2) 1: Switch using DI terminal AC10 Series Frequency Inverter Technical Manual...
  • Page 96 1: Valid F13.30 10.00Hz Sleep frequency V/F SVC (0x0D1E) (0.00~50.00Hz) F13.31 60.0S (0x0D1F) Sleep delay V/F SVC (0.0~3600.0S) F13.32 5.0% (0x0D20) Wake up deviation V/F SVC (0.0~50.0%) F13.33 1.0S (0x0D21) Wake-up delay V/F SVC (0.0~60.0S) AC10 Series Frequency Inverter Technical Manual...
  • Page 97 (0000 ~ 2122) 2: Hour LED "000" digit: Power-down storage 0: No storage 1: Storage LED "0000" digit: Startup mode 0: Re-run from the first stage 1: Re-run from the phase of the downtime AC10 Series Frequency Inverter Technical Manual...
  • Page 98 (0.0~6500.0(s/m/h)) F14.28 10.0 (0x0E1C) PLC thirteenth stage running time V/F SVC (0.0~6500.0(s/m/h)) F14.29 10.0 (0x0E1D) PLC fourteenth stage running time V/F SVC (0.0~6500.0(s/m/h)) F14.30 10.0 (0x0E1E) PLC fifteenth stage running time V/F SVC (0.0~6500.0(s/m/h)) AC10 Series Frequency Inverter Technical Manual...
  • Page 99 The same settings as F14.31 (0000~0031) F14.45 fifteenth direction V/F SVC 0000 (0x0E2D) acceleration and deceleration time The same settings as F14.31 (0000~0031) 10.19 Group F15: Reserved 10.20 Group C0x: Monitoring Parameters Group C00: Basic monitoring AC10 Series Frequency Inverter Technical Manual...
  • Page 100 C01.01 (0x2201) Troubleshooting information V/F SVC C01.02 (0x2202) Fault operating frequency V/F SVC C01.03 (0x2203) Fault output voltage V/F SVC C01.04 (0x2204) Fault output current V/F SVC C01.05 (0x2205) Fault bus voltage V/F SVC AC10 Series Frequency Inverter Technical Manual...
  • Page 101 Motor overload cumulative count C02.18 (0x2312) Motor overload count value C02.19 (0x2313) Wave-by-wave limit V/F SVC Monitor CBC cumulative triggers C02.20 (0x2314) Reserved V/F SVC C01.21 (0x2315) Reserved V/F SVC C02.22 (0x2316) Reserved V/F SVC AC10 Series Frequency Inverter Technical Manual...
  • Page 102 Communication given torque control forward speed limit speed limit (0.0~100.0%) Torque control reverse 0.0% 0x2007/0x3007 Communication given torque control reverse speed limit speed limit (0.0~100.0%) 0.0% 0x2008 /0x3008 PID given Communication given PID given (0.0~100.0%) AC10 Series Frequency Inverter Technical Manual...
  • Page 103 Address Name Description (range) Extended port 0x3400 AC10 series machine defaults to 1 communication mode (0~65535) Bit0: X1 terminal 0-OFF 1-ON Bit1: X2 terminal 0-OFF 1-ON Bit2: X3 terminal 0-OFF 1-ON Bit3: X4 terminal 0-OFF 1-ON Bit4: X5 terminal 0-OFF 1-ON...
  • Page 104 The F00 group parameters are used to set the operating environment and operating conditions of the frequency conversion. For example, parameters access level, use selection and other items. F00.00: Parameter access level  Code Factory setting Name Content (Addr.) (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 105 Communication data format The initialization values of the following common parameter codes are related to the F00.01 setting. Table 11.2 Common Parameter Initialization Settings Common parameter code Setting parameter code Name F00.30 F07.00 Startup mode AC10 Series Frequency Inverter Technical Manual...
  • Page 106 CoPy Upload parameters to the keyboard LoAd Download parameters to the drive When the parameter is copied, if the fault is detected, the fault will be displayed on the keyboard. Code Name Reason Countermeasures AC10 Series Frequency Inverter Technical Manual...
  • Page 107 The control method is selected according to the type and purpose of the motor used. 0: Asynchronous motor V/F control (V/F) This control mode is used for all variable speed control that does not require fast response and precise speed control, as well as the use of multiple AC10 Series Frequency Inverter Technical Manual...
  • Page 108 The input method, selection and priority of the frequency command are explained. Frequency Proportional A, B gain given source A combination mode Frequency Linearization selection given source B Frequency upper and Frequency Priority Run command lower processing command bundle limit processing Multi-speed mode AC10 Series Frequency Inverter Technical Manual...
  • Page 109 F14.00 multi-speed 1 F14.01 multi-speed 2 F14.02 multi-speed 3 F14.03 multi-speed 4 F14.04 multi-speed 5 F14.05 multi-speed 6 F14.06 multi-speed 7 F14.07 multi-speed 8 F14.08 multi-speed 9 F14.09 multi-speed 10 F14.10 multi-speed 11 AC10 Series Frequency Inverter Technical Manual...
  • Page 110 Set the frequency given source A, B combination mode (0 ~ 5) 0: frequency reference source A 1: Frequency reference source B 2: the sum of the frequency given source A and the frequency given source B AC10 Series Frequency Inverter Technical Manual...
  • Page 111 The upper limit of the frequency is selected by F01.11 [upper limit frequency setting method selection], and the lower limit value is set by F01.13 [lower limit frequency]. Output frequency Max frequency Upper limit frequency Lower limit frequency Time AC10 Series Frequency Inverter Technical Manual...
  • Page 112 F01.21 = 0 F01.21 = 1 F01.21 = 2 F01.22 [Acceleration time 1] F01.23[Deceleration time 1] F01.22 [Acceleration time 2] 0 ~ 65000s 0.0 ~ 6500.0s 0.00 ~ 650.00s F01.23[Deceleration time 2] F01.22 [Acceleration time 3] AC10 Series Frequency Inverter Technical Manual...
  • Page 113 Outpu t Freq. < F0 1.35 is added and Dec. according to F01.24 & F01.25 [addition and Dec. time 2] Switching frequency of acceleration and deceleration time F01.20: Acceleration/deceleration time reference frequency  Code Factory setting Name Content (Addr.) (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 114 (0x011A) Acceleration time 3 Set the value of acceleration time 3 (Change with F01.21) F01.27 V/F SVC With power level (0x011B) Deceleration time 3 Set the value of deceleration time 3 (Change with F01.21) AC10 Series Frequency Inverter Technical Manual...
  • Page 115 (0.01 ~ 10.00s) STOP  Code Factory setting Name Content (Addr.) (Setting range) F01.32 Accelerated end S curve V/F SVC 0.20 (0x0120) time Set the acceleration end S curve time (0.01 ~ 10.00s) STOP AC10 Series Frequency Inverter Technical Manual...
  • Page 116 1: Two-phase three-phase modulation automatically switches 11.4 F02 Group: motor 1 parameters The F02 group parameters are used to set the motor 1 parameters and motor application parameters. F02.0x group: basic motor parameters and self-learning options  AC10 Series Frequency Inverter Technical Manual...
  • Page 117 But Suffix-VC of 220v is supported by vector control,So suffix-VC of 220v support auto-tunning. 0: no operation 1: Rotary self-learning 2: Static self-learning 3: stator resistance only static self-learning  -learning mark AC10 Series Frequency Inverter Technical Manual...
  • Page 118 Code Factory setting Name Content (Addr.) (Setting range) F02.17 Stator leakage V/F SVC Actual value conversion (0x0211) inductance Set the stator leakage inductance value. This parameter is read only (0.00 ~ 50.00%) READ AC10 Series Frequency Inverter Technical Manual...
  • Page 119 80% of the frequency at which the actual vibration occurs. When the high speed side cannot ensure the speed is stable, please set it roughly. The actual frequency of vibration is about 120%. AC10 Series Frequency Inverter Technical Manual...
  • Page 120 If the integration time is too long, the responsiveness will decrease and the ability to resist external forces will be weakened. If the integration time is too short, vibration will occur. F03.08: ASR filtering time 2  AC10 Series Frequency Inverter Technical Manual...
  • Page 121 (Setting range) F03.15 Electric state torque 180.0% (0x030F) limit Set the electric state torque limit (0.0 ~ 400.0%) Note: 100.0% corresponds to the rated torque of the motor. F03.16: Power generation torque limit  AC10 Series Frequency Inverter Technical Manual...
  • Page 122 F03.33: Weak magnetic voltage coefficient  Code Factory setting Name Content (Addr.) (Setting range) F03.33 Weak magnetic voltage 97.0% (0x0321) coefficient Set the weak magnetic voltage coefficient (0.0 ~ 120.0%)  F03.34: Output power limit AC10 Series Frequency Inverter Technical Manual...
  • Page 123 Same as torque reference channel A setting selection Hundreds: Channel A, B combination 0: torque reference channel A 1: torque reference channel B 2: Torque given the sum of channel A and channel B AC10 Series Frequency Inverter Technical Manual...
  • Page 124 Set the upper limit of the torque command (0.0 ~200.0%)  F03.53: Lower torque command limit Factory setting Code (Addr.) Name Content (Setting range) F03.53 Torque command 0.0% (0x0335) lower limit Set the torque command lower limit (0.0 ~ 200.0%) AC10 Series Frequency Inverter Technical Manual...
  • Page 125 Set the given torque gain switching frequency (0.00 ~ 50.00Hz)  Factory setting Code (Addr.) Name Content (Setting range) F03.59 100.0% (0x033B) Given torque gain Set the given torque gain (0.0 ~ 500.0%) AC10 Series Frequency Inverter Technical Manual...
  • Page 126 Motor rated rated voltage voltage Torque Torque boosting Output boosting Output voltage frequency voltage frequency Motor rated Motor rated Torque boost Torque boost frequency frequency cutoff frequency cutoff frequency Fixed torque lifting diagram  AC10 Series Frequency Inverter Technical Manual...
  • Page 127 This parameter adjusts the percentage/gain of the output voltage during VF control. F04.1x group: Custom V/F curve This product provides 5 stages of settable voltage-to-frequency ratio to meet the needs of various motors for different voltage-to-frequency ratios. AC10 Series Frequency Inverter Technical Manual...
  • Page 128 Content (Setting range) F04.16 78.0% (0x0410) Self-setting voltage 4 Set the self-set voltage 4. The set value 100.0% corresponds to the rated (0.0 ~ 100.0%) STOP voltage of the motor -set frequency 4  AC10 Series Frequency Inverter Technical Manual...
  • Page 129 34: Energy-saving voltage and voltage recovery rate  Factory setting Code (Addr.) Name Content (Setting range) F04.34 Energy-saving voltage 0.200V/ms (0x0422) and voltage recovery Set the energy saving voltage and voltage recovery rate. (0.000 ~ 2.000V/ms) rate AC10 Series Frequency Inverter Technical Manual...
  • Page 130 Reserved Program run (PLC) pause Reserved Program run (PLC) restart Reserved Acceleration/deceleration time selection terminal 1 Reserved Acceleration/deceleration time selection terminal 2 Reserved Suspension acceleration Reserved Swing frequency input Reserved Swing frequency pause Reserved AC10 Series Frequency Inverter Technical Manual...
  • Page 131 F07.03 [Startup protection selection]. When the keyboard, communication, optional card and terminal three-wire control are running, the original stop command is not restored after the AC10 Series Frequency Inverter Technical Manual...
  • Page 132 PID continues to operate based on the current value. 22: PID feature switching When this terminal is valid, the PID feedback characteristic of the bit setting of parameter F13.07[PID Control Select] will change. When the terminal is AC10 Series Frequency Inverter Technical Manual...
  • Page 133 For the clock input terminal of the counter function, see parameter F08.02 [Counter Maximum] and F08.03 [Counter Set Value]. 43: Counter clear terminal When the terminal is valid, the count record of the counter is cleared. For details, see parameter F08.02 [Counter Maximum] and F08.03 [Counter Set AC10 Series Frequency Inverter Technical Manual...
  • Page 134 F05.13 V/F SVC X2 uneffective check 0.010s (0x050D) Delay time corresponding to the transition of the terminal X1 from the active delay (0.000 ~ 6.000s) state to the inactive state Note: AC10 Series Frequency Inverter Technical Manual...
  • Page 135 In this mode, the three-wire operation control terminal (Xi) is the stop operation terminal, and the running command is generated by the forward rotation operation terminal X1 (forward rotation operation), and the direction is controlled by the reverse rotation operation terminal X2 (reverse rotation operation). The three-wire operation control terminal (Xi) is an effective input. AC10 Series Frequency Inverter Technical Manual...
  • Page 136 When the terminal adjustment frequency is incremented or decremented, the frequency record is maintained after the machine is powered off or stopped. During power-on operation, the frequency converter increases and decreases the frequency from the last stop. AC10 Series Frequency Inverter Technical Manual...
  • Page 137 100.00% (0x0522) frequency corresponding Set the percentage of the set value corresponding to the maximum input (0.00 ~ 100.00%) setting frequency of PUL The linear processing of the PUL input frequency is shown below: AC10 Series Frequency Inverter Technical Manual...
  • Page 138 There are two analog AI inputs in the drive. The input source can be divided into voltage input range of 0~10.0V, current input range is 0~20mA, and the matching input source is selected by the DIP switch on the control board according to different signal sources. The factory default dial switch dials the voltage input. 1: AI input signal type  AC10 Series Frequency Inverter Technical Manual...
  • Page 139 The value of the AI input signal after being sampled by the drive. AI input signal Corresponding to the sampling value of the drive 0~10V 0.0%~100.0% 0~20mA 0.0%~100.0% The AI linear processing is shown below: AC10 Series Frequency Inverter Technical Manual...
  • Page 140 Set the percentage of the set value corresponding to the lower limit of curve 0.00% (0x053D) corresponding setting (0.00 ~ 100.00%) F05.62 Curve 1 inflection point V/F SVC 30.0% (0x053E) Set the value of curve 1 inflection point 1 (0.0 ~ 100.0%) AC10 Series Frequency Inverter Technical Manual...
  • Page 141 Set the characteristics of AI as a digital input terminal (0 ~ 0x0011) Unit: AI 0: active low 1: active high Ten: reserved  Code Factory setting Name Content (Addr.) (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 142 AO output analog current) (voltage / current) AO output gain 200% AO offset +10.0% AO output gain 100% Monitoring AO offset Monitoring amount 0.0% amount AO offset -10.0% AO analog output and gain, offset schematic AC10 Series Frequency Inverter Technical Manual...
  • Page 143 Reserved Reserved PUL input value PUL input lower limit PUL input upper limit Module temperature 1 0 degrees Celsius 100 degrees Celsius Module temperature 2 0 degrees Celsius 100 degrees Celsius RS485 given 1000 AC10 Series Frequency Inverter Technical Manual...
  • Page 144 Program run cycle completion Reserved The running phase of the program is Reserved completed. PID feedback exceeds the upper limit Refer to F13.27 parameter description PID feedback is below the lower limit Refer to F13.28 parameter description AC10 Series Frequency Inverter Technical Manual...
  • Page 145 Code Factory setting Name Content (Addr.) (Setting range) F06.21 Output terminal V/F SVC (0x0615) function selection Setting the function of the multi-function output terminal Y (0 ~ 63)  F06.22: Relay 1 function selection AC10 Series Frequency Inverter Technical Manual...
  • Page 146 When the counter reaches the set value, the output terminal outputs a valid signal, and continues to count until the counter exceeds the maximum value, causing the counter to be cleared, and the output valid signal is cancelled. See parameter F08.03 [Counter set value]. 24: Energy braking AC10 Series Frequency Inverter Technical Manual...
  • Page 147 It is used to set the signal such as frequency coincidence and frequency arrival to the multi-function output terminal. The drive contains two sets of frequency detection judgment parameters. The output frequency is detected as shown below: Frequency level detection diagram AC10 Series Frequency Inverter Technical Manual...
  • Page 148 The set of parameters sets any one of the monitoring parameters for comparison by the comparator, and selects a multi-function output terminal, an alarm or an alarm according to the judgment result. Meet the comparison output of various monitoring variables.  F06.54: Comparator 1 (CP1) Factory setting Code (Addr.) Name Content (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 149 The virtual terminal is characterized by the combination of vXi and vYi. When you want to use the Y terminal output signal as the X terminal input signal, you can use the internal vXi and vYi virtual connection to achieve the purpose of use, thus saving the actual X and Y terminals for other Aspect use. AC10 Series Frequency Inverter Technical Manual...
  • Page 150 0: Internal connection with virtual vY1 1: Link to physical terminal X1 2: Is the function code setting valid? Ten places: virtual vX2 0: Internal connection with virtual vY2 1: Link to physical terminal X2 AC10 Series Frequency Inverter Technical Manual...
  • Page 151 Set the delay time for the vY1 terminal to switch from ON to OFF (0.000 ~ 60.000s) F06.75 vY2 output OFF delay V/F SVC 0.010 (0x064B) time Set the delay time for the vY2 terminal to switch from ON to OFF (0.000 ~ 60.000s) AC10 Series Frequency Inverter Technical Manual...
  • Page 152 When the default is 0.00s, the actual time of starting the pre-excitation is automatically calculated according to the motor parameters.   The S/T2 model does not support pre-excitation before starting.  F07.02: Starting frequency AC10 Series Frequency Inverter Technical Manual...
  • Page 153 0: Invalid frequency control direction If the calculation result is negative, the drive outputs a frequency of 0.00Hz. 1: Frequency control direction is valid If the calculation result is negative, the drive changes the current running direction and outputs the corresponding frequency. Note: AC10 Series Frequency Inverter Technical Manual...
  • Page 154 The interval between the drive switching from the running state to the stop and restart (0.000 ~ 60.000s) STOP state and accepting the running command This function is used in situations where frequent start and stop commands are not allowed. AC10 Series Frequency Inverter Technical Manual...
  • Page 155 Exit the positive and negative dead zone status: Exit method Control form after exit Positive reversal of dead time to Enter normal start control Reverse command Enter normal start control Stop command Enter shutdown control AC10 Series Frequency Inverter Technical Manual...
  • Page 156 Start the stop DC braking state to start timing; exit the stop DC braking state, clear the timing, and enter the re-timer next time.  Factory setting Code (Addr.) Name Content (Setting range) F07.25 V/F SVC 0000 (0x0719) Speed tracking mode Set the mode of tracking tracking (0x0000 ~ 0x0111) STOP AC10 Series Frequency Inverter Technical Manual...
  • Page 157 1: valid Note: The jog S curve time is the same as the non-jog S curve, and both are F01.31~F01.34.  F07.34: Jog stop mode  Code Factory setting Name Content (Addr.) (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 158 When the frequency command reaches the range of the skip frequency band, it will switch to constant speed operation. AC10 Series Frequency Inverter Technical Manual...
  • Page 159 When selecting a different input source, be aware of the upper frequency limit of the signal.   When F08.00 = 0 mode, the input signal should be used in conjunction with the F05.0x = 42 [multi-function input terminal = counter input terminal] setting terminal.  AC10 Series Frequency Inverter Technical Manual...
  • Page 160 Pulse number per meter Set the number of pulses per meter (0.1~ 6500.0)  Code Factory setting Name Content (Addr.) (Setting range) F08.05 V/F SVC (0x0805) Set length Set length (0~ 65000M) STOP Note: AC10 Series Frequency Inverter Technical Manual...
  • Page 161 (Addr.) (Setting range) F08.31 Swing frequency control V/F SVC 0x0000 (0x081F) selection Select the swing frequency control method (0x0000~ 0x0111) STOP Units: Startup mode 0: automatic 1: terminal manual Ten digits: pendulum amplitude control AC10 Series Frequency Inverter Technical Manual...
  • Page 162 When the point is below, the drive works normally. 1: Acceleration/deceleration is valid, constant speed is invalid The overcurrent suppression function is valid during the acceleration/deceleration of the drive, and the overcurrent suppression is invalid at constant speed. AC10 Series Frequency Inverter Technical Manual...
  • Page 163 Unit position: three-phase current detection and non-zero judgment, 0001 (0x0A04) setting 2 output failure E.HAL (0000~0001) STOP 0: off 1: on F10.1x Group: Voltage protection Code (Addr.) Factory setting Name Content Adjustable attribute (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 164 When the bus voltage reaches or exceeds F10.12 [bus overvoltage suppression point] during the running of the drive, the output frequency is automatically adjusted to suppress the bus voltage from rising, avoiding the drive jumping E.OU [overvoltage fault], the overvoltage suppression function diagram As shown below. AC10 Series Frequency Inverter Technical Manual...
  • Page 165 Note: When using the energy consumption braking function, please turn off the overvoltage suppression function and set F10.11 to 0; otherwise, overvoltage suppression may inhibit the rise of the bus voltage and fail to reach the braking action point. Code (Addr.) Factory setting Adjustable Name Content (Setting range) attribute AC10 Series Frequency Inverter Technical Manual...
  • Page 166 2: Turn on, detect input missing phase report fault E.ILF, free stop Set whether the input and output phase loss protection functions are enabled. Unit: Output phase loss protection function selection 0: Off, the output phase loss protection function is invalid. AC10 Series Frequency Inverter Technical Manual...
  • Page 167 STOP fan stops running. Set the time from the release of the running command to the stop of the cooling fan. After the drive stops running, the fan will stop running after this time. AC10 Series Frequency Inverter Technical Manual...
  • Page 168 0: Invalid. The overload protection function is invalid at low speed (below 5 Hz). 1: Valid, the overload protection function is valid at low speed (below 5 Hz). Code (Addr.) Factory setting Adjustable Name Content (Setting range) attribute AC10 Series Frequency Inverter Technical Manual...
  • Page 169 When the Y terminal function is selected as 27 [Overload pre-alarm output 1], the drive outputs an early warning signal through the Y terminal. Code (Addr.) Factory setting Adjustable Name Content (Setting range) attribute AC10 Series Frequency Inverter Technical Manual...
  • Page 170 F10.40 [Speed deviation excessive protection action]. Code (Addr.) Factory setting Adjustable Name Content (Setting range) attribute AC10 Series Frequency Inverter Technical Manual...
  • Page 171 (0 ~100.0) STOP Set the waiting time from the fault of the drive to each reset. During this time, the keyboard displays the fault character at this time, but the running indicator is still lit. AC10 Series Frequency Inverter Technical Manual...
  • Page 172 5: Keyboard command channel and communication naming channel switch 6: Terminal command channel and communication naming channel switch 7: keyboard, terminal, communication command channel cycle switching  Factory setting Code (Addr.) Name Content (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 173 2: Both internal and external are valid, the stop/reset command takes precedence; when both forward and reverse are active, the command is invalid. LED ten: reserved LED Hundreds: Reserved LED Thousands: Keyboard Test (Communication Success Rate) F11.1x group: Status interface cyclic monitoring  AC10 Series Frequency Inverter Technical Manual...
  • Page 174 (0000~0763) Used to set the contents of the two-line keyboard display parameters parameter 4 Keyboard display parameters: used to set the contents of the single-line keyboard and double-line keyboard display parameters. AC10 Series Frequency Inverter Technical Manual...
  • Page 175 F11.24 Monitoring parameter 0~F: the larger the value, the deeper the filter 0x0000 (0x0B18) filtering selection Ten: reserved (0x0000 ~0x 000F) Hundreds: reserved Thousands: reserved  F11.25: Display selection when the motor is self-learning AC10 Series Frequency Inverter Technical Manual...
  • Page 176 Parameter [F11.30] sets the MODBUS/external keyboard to choose one. This parameter is not restored with the [F00.03] parameter. Users are strongly advised to unlock the hardware connection of another channel when using one of them. AC10 Series Frequency Inverter Technical Manual...
  • Page 177 0: The write operation has a response 1: Write operation has no response Modbus communication response delay  Factory setting Code (Addr.) Name Content (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 178 4: Host upper limit frequency 5: the given torque of the host 6: host output torque 7: Reserved 8: Reserved 9: Host PID given A: Host PID feedback B: Reserved C: active current component  AC10 Series Frequency Inverter Technical Manual...
  • Page 179 8: Terminal selection The PID reference value is selected by the combination of multi-function input terminals. The multi-function input terminal is set by [F05.00~F05.09]. 9: Communication gives a working current. Terminal switching selection diagram: AC10 Series Frequency Inverter Technical Manual...
  • Page 180 The PID controller given signal source and the PID controller feedback signal source cannot be set to the same channel; otherwise the PID will not work normally. F13.04: Feedback signal low pass filtering time  AC10 Series Frequency Inverter Technical Manual...
  • Page 181 The PID feedback amount is the maximum deviation allowed for the PID given; when the feedback amount is within this range, the PID adjustment stops and the output remains unchanged; the reasonable use of this function helps to coordinate the accuracy and stability of the system output. contradiction.  AC10 Series Frequency Inverter Technical Manual...
  • Page 182 0: Do not switch PID parameter to select PID parameter group 1. 1: Use D1 terminal to switch Multi-function terminal function selection to set 23 (PID parameter switching), select PID parameter group 1 when the AC10 Series Frequency Inverter Technical Manual...
  • Page 183 Code (Addr.) Name Content (Setting range) F13.23 0.0% V/F SVC (0x0D17) PID output lower limit Used to set the PID output lower limit value (-100.0~Fb.19)  Factory setting Code (Addr.) Name Content (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 184 When the PID feedback characteristic is inverse characteristic: the value of PID given plus wake-up deviation [F13.32] is compared with the PID feedback. If it continues to be greater than the wake-up delay [F13.33], it will exit the sleep state and enter the normal running state.  Factory setting Code (Addr.) Name Content (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 185 Factory setting Code (Addr.) Name Content (Setting range) F14.03 40.00Hz V/F SVC (0x0E03) ~ PLC multi-speed 4 Set the 4th stage running frequency in PLC program operation and multi- (0.00 Maximum step speed control frequency) AC10 Series Frequency Inverter Technical Manual...
  • Page 186 Name Content (Setting range) F14.12 50.00Hz V/F SVC (0x0E0C) ~ PLC multi-speed 13 Set the 13th stage running frequency in PLC program operation and multi- (0.00 Maximum step speed control frequency) -speed 14  AC10 Series Frequency Inverter Technical Manual...
  • Page 187 0: After stopping the operation command after single cycle, the drive starts running from the first speed. The time unit is set by the LED tens of [F14.15]; the running time is set by the parameter [F14.16~F14.30]. The running direction and acceleration/deceleration time are selected by the parameter AC10 Series Frequency Inverter Technical Manual...
  • Page 188 PLC program running 0.0~6500.0(s/m/h)  Factory setting Code (Addr.) Name Content (Setting range) F14.20 10.0s PLC 5 stage running V/F SVC (0x0E14) time Set the 5 run time of the PLC program running 0.0~6500.0(s/m/h) AC10 Series Frequency Inverter Technical Manual...
  • Page 189 Name Content (Setting range) F14.29 10.0s PLC 14 stage running V/F SVC (0x0E1D) time Set the 14 run time of the PLC program running 0.0~6500.0(s/m/h)  Factory setting Code (Addr.) Name Content (Setting range) AC10 Series Frequency Inverter Technical Manual...
  • Page 190 9: PLC 9th direction and acceleration and deceleration time Factory setting Code (Addr.) Name Content (Setting range) F14.39 PLC 9 direction and V/F SVC 0000 (0x0E27) acceleration Used to set the 9 running direction and acceleration / deceleration time (0000~0031) deceleration time AC10 Series Frequency Inverter Technical Manual...
  • Page 191 1: acceleration and deceleration time 2 2: Acceleration and deceleration time 3 3: Acceleration and deceleration time 4 Hundreds: reserved Thousands: reserved Revised record Issue date Revised number Change content April 24, 2019 V0.0 Original Issue AC10 Series Frequency Inverter Technical Manual...

This manual is also suitable for:

Sis series