Download Print this page

Veichi AC10 Series Technical Manual page 100

Advertisement

Function Table
Parameter
code
Name
(address)
C00.00 (0x2100)
Given frequency
C00.01 (0x2101)
Output frequency
C00.02(0x2102)
Output current
C00.03 (0x2103)
Input voltage
C00.04 (0x2104)
The output voltage
C00.05 (0x2105)
Mechanical speed
C00.06 (0x2106)
Given torque
C00.07 (0x2107)
Output torque
C00.08 (0x2108)
PID given
C00.09 (0x2109)
PID feedback
C00.10 (0x210A)
Output Power
C00.11 (0x210B)
bus voltage
C00.12 (0x210C)
Module temperature 1
C00.13 (0x210D)
Module temperature 2
C00.14 (0x210E)
Input terminal X is on
C00.15 (0x210F)
Output terminal Y is on
C00.16(0x2110)
Analog AI input value
C00.17 (0x2111)
Reserved
C00.18 (0x2112)
Keyboard potentiometer input value
C00.19 (0x2113)
Pulse signal PUL input value
C00.20 (0x2114)
Analog output AO
C00.21 (0x2115)
Reserved
C00.22 (0x2116)
Counter count value
C00.23 (0x2117)
Power-on running time
Accumulated running time of the
C00.24 (0x2118)
machine
C00.25 (0x2119)
Drive power level
C00.26 (0x211A)
Drive rated voltage
C00.27 (0x211B)
Drive rated current
C00.28 (0x211C)
Software version
C00.29 (0x211D)
PG feedback frequency
C00.30 (0x211E)
Timer timing
C00.31 (0x211F)
PID output value
C00.32 (0x2120)
Drive software subversion
C00.33(0x2121)
Encoder feedback angle
C00.34 (0x2122)
Z pulse cumulative error
C00.35 (0x2123)
Z pulse count
C00.36 (0x2124)
Failure warning code
Cumulative power consumption (low
C00.37 (0x2125)
level)
C00.38 (0x2126)
Cumulative power consumption (high)
C00.39 (0x2127)
Power factor angle
C01 Group: Fault monitoring
Parameter code (address)
C01.00 (0x2200)
C01.01 (0x2201)
C01.02 (0x2202)
C01.03 (0x2203)
C01.04 (0x2204)
C01.05 (0x2205)
AC10 Series Frequency Inverter Technical Manual
Content
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
Name
Fault type diagnostic information
Troubleshooting information
Fault operating frequency
Fault output voltage
Fault output current
Fault bus voltage
96
Signal level of multi-function analog output
10V corresponds to the maximum frequency (60Hz)
10V corresponds to the maximum frequency
10V corresponds to the rated current of the double motor
(5A)
10V corresponds to 380V
10V corresponds to the rated voltage of the motor 360V
10V corresponds to the maximum frequency of
mechanical speed
10V corresponds to +/-200%
10V corresponds to +/-200%
10V corresponds to 100%
10V corresponds to 100%
5V corresponding rated bus voltage
10V corresponds to 100 ° C
10V corresponds to 100 ° C
10V corresponds to 10V
10V corresponds to 10V
Content
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC

Advertisement

loading

This manual is also suitable for: