F01.08
Run command bundled
(0x0108)
given frequency
RUN
F01.09
Keyboard
(0x0109)
frequency
RUN
F01.1x group: Frequency command
Parameter
(address)
Name
djustable
attribute
F01.10
(0x010A)
Maximum frequency
STOP
F01.11
(0x010B)
Upper frequency source selection
RUN
F01.12
Upper limit frequency digital
(0x010C)
setting
RUN
F01.13
(0x010D)
Lower limit frequency
RUN
F01.14
(0x010D)
Resolution of frequency reference
STOP
F01.2x-F01.3x group: Acceleration and deceleration time
Parameter
(address)
Name
djustable
attribute
F01.20
Acceleration/deceleration
(0x0114)
reference frequency
STOP
V/F SVC
When this parameter is valid, it is used to set the channel source frequency
channel for each running command channel.
LED "0" digit: Keyboard command instruction bundle
LED "00" digit: Terminal command command bundle
LED "000" digit: Bundle of communication command instructions
LED "0000" digit: Optional Card Command Command Bundle
0: No binding
1: Keyboard digital given frequency
2: Keyboard analog potentiometer given
3: Current/voltage analog AI given
4: Reserved
5: Reserved
6: Terminal pulse PUL given
7: Communication given
8: Terminal UP/DW control
9: PID control given
A: Program control (PLC) given
B: Option card
C: Multi-speed speed given
D: Reserved
digital
given
V/F SVC
Used to set and modify the keyboard digital setting frequency.
Content
V/F SVC
The maximum frequency that the frequency converter
can set.
V/F SVC
Select a given source for the upper limit frequency of the
drive.
0: Upper limit frequency number given
1: Keyboard analog potentiometer given
2: Current/voltage analog AI given
3: Reserved
4: Reserved
5: Terminal pulse PUL given
V/F SVC
6: RS485 communication given
The upper line frequency is given when F01.11 is set to
7: Reserved
0.
V/F SVC
Given a lower frequency limit, the given frequency is
limited.
V/F SVC
0:0.00Hz
1:r/min;
2:0.1Hz(compatible with high frequency reference given
like 3000Hz,developing )
Content
V/F SVC
Set the reference frequency to calculate the acceleration/deceleration time.
time
0: Maximum frequency
1: Fixed frequency 50Hz
2: Set the frequency
63
0000
(0000 ~ DDDD)
50Hz
(0.00 to upper
limit frequency
setting)
Factory default (setting range)
50.00Hz
(upper
frequency~600.00Hz)
0
(0~7)
0.00Hz
(0.00~upper
limit
digital setting)
0.00Hz
(0.00~upper
limit
digital setting)
0.00Hz
(developing )
AC10 Series Frequency Inverter Technical Manual
Function Table
limit
frequency
frequency
Factory
default
(setting
range)
0
(0 ~ 2)