F10.13
(0x0A0D)
Bus overvoltage suppression gain
RUN
F10.14
(0x0A0E)
Energy brake enable
RUN
F10.15
Energy consumption braking action
(0x0A0F)
voltage
RUN
F10.16
(0x0A10)
Bus undervoltage suppression
STOP
F10.17
(0x0A11)
Bus undervoltage suppression point
STOP
F10.18
(0x0A12)
Bus undervoltage suppression gain
RUN
F10.19
(0x0A13)
Bus undervoltage protection point
STOP
F10.2x group: Auxiliary protection
Parameter
(address)
Name
djustable
attribute
F10.20
Input and output phase loss protection
(0x0A14)
options
STOP
F10.21
(0x0A15)
Input phase loss threshold
STOP
V/F SVC
Set the response of overvoltage suppression
V/F SVC
Set whether the energy brake function is on
0: off
1: Turn on, but turn off the overvoltage
suppression function
2: Turn on, and turn on the overvoltage
suppression function.
V/F SVC
Set the energy consumption braking action
voltage, when the bus voltage is greater than
this value, the energy consumption brake starts
to act.
V/F SVC
When the bus voltage is lower than the
undervoltage suppression point, the operating
frequency is automatically adjusted to
suppress the bus voltage from decreasing,
preventing the undervoltage fault.
0: Off
1: On
V/F SVC
Set bus voltage value for trigger undervoltage
suppression function
V/F SVC
Set the response effect of undervoltage
suppression
V/F SVC
The lower limit voltage allowed by the set bus
voltage. Below this value, the drive reports an
undervoltage fault.
Content
V/F SVC
Set whether the input and output phase loss protection functions
are enabled.
LED "0" digit: Output phase loss protection
0: Off 1: On
LED "00" digit: Input phase loss protection
0: Off
1: On, detected the input missing phase report warning A.ILF,
continue to run
2: Turn on, detect input missing phase report fault E.ILF, free stop
V/F SVC
Set the percentage of voltage detection of the input phase loss
detection function, 100% corresponds to the rated bus voltage
83
100.0%
(0.0~500.0%)
2
(0 ~2)
T3
T3: 740
overvoltagepoint
S2: 360
: 820V
(T3:650 ~800
(750 ~840)
S2:350 ~390)
S2
Also subject
overvoltagepoint
to overvoltage
400V
limit
(360 ~410)
0
(0 ~ 1)
T3
T3: 430
overvoltagepoint
S2: 240
: 820V
(T3: 350 ~450
(750 ~840)
S2: 180 ~260)
S2
Also subject
overvoltagepoint
to overvoltage
400V
limit
(360 ~410)
100.0%
(0.0~500.0%)
T3
T3: 320
overvoltagepoint
S2: 190
: 820V
(T3: 300 ~400
(750 ~840)
S2: 160 ~240)
S2
Also subject
overvoltagepoint
to overvoltage
400V
limit
(360 ~410)
Factory default
(setting range)
021
(000 ~ 121)
10%
(0 ~30.0%)