Parameter details
Code
Name
(Addr.)
F08.01
(0x0801)
Counting frequency
RUN
The monitoring parameter C00.22 [count value] is obtained by dividing the count signal.
Note:
The values compared with F08.02 [Timer Max] and F08.03 [Timer Set] are the count values in C00.22.
F08.02: Counter maximum
Code
Name
(Addr.)
F08.02
(0x0802)
Counter maximum
RUN
F06.21~F06.24=22[Multi-function output terminal=Counter reaches the maximum value], when the count value reaches the value set by F08.02, the
corresponding output terminal outputs a valid signal, and the C00.22 count value is cleared. zero. The output signal width is equal to the clock period of
the valid signal of the external input terminal, that is, when the next count signal is input, the output terminal stops outputting the valid signal.
Code
Name
(Addr.)
F08.03
(0x0803)
Counter setting
RUN
F06.21~F06.24=23[Multi-function output terminal=Counter reaches the set value], when the count value reaches the value set by F08.03, the valid signal
is output at the corresponding output terminal, and the output signal width is the count value. When the value specified by parameter F08.02 is exceeded,
the output terminal stops outputting a valid signal when the counter is cleared.
Counter maximum value and counter setting value related operation diagram
Note:
The counter set value is required to be less than or equal to the timer maximum.
The count value of C00.22 can be cleared by the terminal set by F05.0x = 43 [multi-function input terminal = counter clear].
Fixed length control
F08.06 [Actual length] = C00.22/F08.04.
When F08.06 [actual length] is greater than or equal to F08.05 [set length], the output signal can be output through the F6.21~F06.42=20[multi-function
output terminal = meter length] output terminal for stop control or The next action starts the control.
Code
Name
(Addr.)
F08.04
(0x0804)
Pulse number per meter
RUN
Code
Name
(Addr.)
F08.05
(0x0805)
Set length
STOP
Note:
AC10 Series Frequency Inverter Technical Manual
Content
V/F SVC
Set the count frequency
Content
V/F SVC
Set the maximum value of the counter.
Content
V/F SVC
Set the counter setting value.
Content
V/F SVC
Set the number of pulses per meter
Content
V/F SVC
Set length
156
Factory setting
(Setting range)
0
(0~ 6000)
Factory setting
(Setting range)
1000
(0~ 6500)
Factory setting
(Setting range)
500
(0~ 6500)
Factory setting
(Setting range)
10.0
(0.1~ 6500.0)
Factory setting
(Setting range)
500
(0~ 65000M)