Chapter 1: Safety Requirement and Cautions

To ensure safety of your health, equipment and property, please read this chapter carefully before using
the solar pump inverter and act in compliance with the instructions when installing, debugging, running
and overhauling the inverter.
1.1 Safety Definition
Danger: it will cause danger of serious injuries and even death while operating against the rules.
Caution: it will cause danger of light injuries or equipment destruction while operating against the
rules.
Note: some information is useful while operating and using solar pump inverter.
1.2 Safety Requirements and Cautions
●Before Installation
1. Only qualified personnel can operate the equipment. Before operating, be sure to carefully
read the manual. The safe operation depends on the proper processes of choosing models,
carrying, installation, operation and maintenance.
2. Don't use the damaged or incomplete solar pump inverters; Otherwise, there is risk of injury.
●Installation
1. Please install the solar pump inverter on metal or other nonflammable material, and keep it
away from the combustible material. Otherwise there is danger of fire.
2. No unauthorized modification to the solar pump inverter; Otherwise there is danger of
damage.
3. Normal solar pump inverter without explosion-proof cannot be installed where with explosive
gas or dust; Otherwise there is danger of explosion.
●Wiring
1. Wire is connected only when the main circuit is cut off, otherwise there is a danger of shock.
2. Wire is connected by professional person only. Otherwise there is a danger of shock.
3. Earth must be reliable. Otherwise there is a danger of shock.
4. DC power supply should not be connected to output terminals U, V, W, otherwise there is a
danger of damage to solar pump inverter.
5. No drop of bolt, spacer, metal stick, conducting wire or other things into the inner of solar
pump inverter; Otherwise there is a danger of fire or damage to solar pump inverter.
1. If the damage to solar pump inverter or other equipment is caused by improper wiring and
utilization or unauthorized alteration, the user should shoulder all responsibilities.
SI30 Solar Pump Inverter Manual
Danger
Danger
Danger
Attention
1

Advertisement

Table of Contents
loading

Summary of Contents for Veichi SI30 series

  • Page 1: Chapter 1: Safety Requirement And Cautions

    SI30 Solar Pump Inverter Manual Chapter 1: Safety Requirement and Cautions To ensure safety of your health, equipment and property, please read this chapter carefully before using the solar pump inverter and act in compliance with the instructions when installing, debugging, running and overhauling the inverter.
  • Page 2 SI30 Solar Pump Inverter Manual 2. Please make sure all wirings meet EMC requirements and satisfy safety standards in the local area; Please refer to recommendations in this manual or national standards of wire diameter to avoid accidents. 3. Static electricity on human body would seriously damage internal MOS transistor, etc. Don’t touch the printed circuit boards, IGBT or other internal devices without anti-static measurements;...
  • Page 3: Operation

    SI30 Solar Pump Inverter Manual Attention 1. Please set the parameter of solar pump inverter cautiously; Otherwise it will damage equipment. ●Operation Danger 1. Before running, please check and confirm the application range of the machine and equipment once more; Otherwise it will cause accidents. 2.
  • Page 4: Technical Specification

    SI30 Solar Pump Inverter Manual 4. Solar pump inverter, in a certain output frequency range, can meet the mechanical resonance of the load equipment. To avoid it, you can set up jumping frequency. 5. As output voltage of the inverter is pulse-wave type, if there is capacity which can improve power factor or pressure-sensitive resistance which used for thunder-proof in the voltage output side, the solar pump inverter will break off or its parts will be damaged, so it is necessary to dismantle them.
  • Page 5: Chapter 2: Installation And Wiring

    SI30 Solar Pump Inverter Manual Chapter 2: Installation and Wiring 2.1 Products Appearance 2.2 Open Cover Remove 4 fixed screws in the cover and turn from right to left to open the top cover, as shown below: Remove 4 fixed Turn from right to left to open the top screws cover...
  • Page 6 SI30 Solar Pump Inverter Manual 2.3 Inverter Dimension Dimensions for 4 kW and below are shown as follow: M6(installation hole)
  • Page 7 SI30 Solar Pump Inverter Manual 5.5kW dimension as follow: 195.87 7.5(installation hole)
  • Page 8: Standard Wiring

    SI30 Solar Pump Inverter Manual Solar Controller Wiring ● Standard Wiring Power Input Breaker Contactor AC/DC Module ( ) + Output Power Filter Solar Pump Inverter Input Shielded cable or amoured cable +24V (grounding nearby inverter) (Earthing resistance is less than 10Ω) (forward running) (reversal running) (water fulfilled detection alarm)
  • Page 9 SI30 Solar Pump Inverter Manual 2.5 Terminal diagram ● D3 model with output filter ● D5 model with output filter U1 V1 W1 U1 V1 W1 U V W U V W...
  • Page 10 SI30 Solar Pump Inverter Manual ● Inverter board terminal diagram ● Terminal diagram of control panel...
  • Page 11: Chapter 3: Basic Operation And Trial Run

    SI30 Solar Pump Inverter Manual Chapter 3: Basic Operation and Trial Run 3.1 Keyboard Layout and Function Specification (optional) ● Keyboard Appearance ● Key Function Name Function Enter menu while standby or running. Press this key to return Menu key back while modifying parameters.
  • Page 12 SI30 Solar Pump Inverter Manual Machine stops if press it while run/stop is controlled by keyboard. Its efficiency range is defined via function no [F4.03]. Inverter Stop/reset key resets if press it in fault state (no reset if fault is not solved). Keyboard Can be used as input channel for given frequency, upper potentiometer...
  • Page 13 SI30 Solar Pump Inverter Manual ● Core Control Mode Selection Here by setting F0.00 = 0 (VC without PG) as an example to introduce, ● Motor Parameter Setting According to the motor nameplate [F5.02] (Motor rated power), [F5.03] (motor rated frequency), [F5.04] (motor rated speed), [F5.05] (motor rated Voltage).Other motor parameters can be obtained through self-learning of the inverter, the specific methods of operation are as follows:...
  • Page 14 3.2 GPRS-D module and APP application (optional) ●GPRS-D module appearance and wiring diagram ●APP main interface and function introduction VEICHI: Company LOG &Chinese/ English switch Version: Current APP version Digital tube: current value display area A zone: current numeric unit display area...
  • Page 15 SI30 Solar Pump Inverter Manual 3.3 Panel button (standard configuration) It is able to complete start /stop operation on inverter by pressing [Start/Stop] key in the cover panel only when F0.02=0. Pressing the key to start it when it is in stop status. While it is in running status, press the key to stop it.
  • Page 16: Chapter 4: Fault Diagnosis And Solution

    SI30 Solar Pump Inverter Manual Chapter 4: Fault Diagnosis and Solution This chapter describes the inverter fault, alerts, and operation of the failure on the inverter, the display information on inverter and countermeasures. In addition, the poor condition of the drive and motor failures will be briefly described in this chapter.
  • Page 17 SI30 Solar Pump Inverter Manual deceleration ● The load or inertia of ● Install external load is too large braking resistor or unit ●Solar drive capacitor is ● Select an AC drive of too small matching power class. ● Check the load ●Load sudden change Over current at change...
  • Page 18 SI30 Solar Pump Inverter Manual ●Temperature detection ● Change the same circuit fault。 new fan. ● Seek support from factory. ●Make the environment ●Temperature is too meeting the high. requirement. ● Air channel is blocked. ● Clear the air channel. Rectifier ●...
  • Page 19 SI30 Solar Pump Inverter Manual supply wiring. ● Check 3-phase Output phase ●3-phase output power output voltage and E.oLF loss open phase current. ● Check wiring. Output earth ●Check wiring and E.Gnd terminal short ●Output earth insulation. circuit. ●Seek support from Current ●...
  • Page 20: Chapter 5 Parameters List

    SI30 Solar Pump Inverter Manual Chapter 5 Parameters List “●”:Stands for parameters can modify during running “〇”:Stands for parameters can’t modify during running “×”:Stands for parameter read only, can’t modify “–”:Stands for factory parameters, only for factory ※ “ ”:Stands for relative with AC drive models ★...
  • Page 21 SI30 Solar Pump Inverter Manual ★ Running Control Parameters Funct Default prop Comm. Function name Setting range and definition setting erty code 0:Deceleration to stop F1.07 Stop mode ● 0x107 1:Free stop LED "0"digit, acceleration /deceleration time reference 0:Maximum frequency 1:Fixed frequency Acceleration/decelerat LED"00"digit:...
  • Page 22 SI30 Solar Pump Inverter Manual ★ Optional Keyboard and Display Parameters Functi Default prop Comm. Function name Setting range and definition setting erty code 0:No lock 1:Function parameters locked Parameters and button F4.00 2:Function code and parameters ● 0x400 lock selection lock ( except RUN/STOP/JOG) 3:Function parameters all locked F4.01...
  • Page 23 SI30 Solar Pump Inverter Manual LED "0"digit:The first group The second line of LED "00"digit:The second group F4.13 keypad display in LED "000"digit:The third group CA42 ● 0x40D running status LED "0000"digit digit:The forth group LED "0"digit:The first group The second line of LED "00"digit:The second group F4.14 keypad display at stop...
  • Page 24 SI30 Solar Pump Inverter Manual Encoder installation 〇 F5.25 0.0°~360.0° model set 0x519 angle of PM Inject frequency at 〇 F5.26 50.0Hz~1000.0Hz 300.0Hz 0x51A high frequency Inject voltage at high 0.1% ~100.0% 〇 F5.27 20.0% 0x51B frequency Back EMF identify 0.1% ~100.0% 〇...
  • Page 25 Functi Default prop Comm. Function name Setting range and definition setting erty code LED "0"digit:485 communication main-slave selection: Master-slave LED "00"digit:Veichi CAN 〇 Fd.00 0xD00 selection(485 &CAN) main-slave selection: 0:Slave 1:Master LED "0"digit:485 communication 0:1200 bps 1:2400 bps 2:4800 bps 3:9600 bps...
  • Page 26 SI30 Solar Pump Inverter Manual 0:Modbus protocol RS485 communication 〇 Fd.10 1:Virtual oscilloscope protocol 0xD0A protocol 2:Reserved Note: If you need a detailed description of parameters, please contact the manufacturer to order "AC100 Vector Inverter Manual". ★ Photovoltaic Pump Special Parameters Functi Default prop...
  • Page 27 SI30 Solar Pump Inverter Manual Low speed protection FE.16 auto restore working 0.0~3000.0s 10.0s ● 0xE10 time Dry run protection FE.17 0.0~999.9A 0.0A ● 0xE11 detect current Dry run protection FE.18 0.0~3000.0s 10.0s ● 0xE12 detect time Dry run auto restore FE.19 0.0~3000.0s 10.0s...
  • Page 28 SI30 Solar Pump Inverter Manual FE.39 Flow curve 2 0.0~999.9m 10.0 m ● 0xE27 FE.40 Flow curve 3 0.0~999.9m 15.0 m ● 0xE28 FE.41 Flow curve 4 0.0~999.9m 20.0 m ● 0xE29 Flow calculating revise FE.42 0.0~999.9m 0.0m ● 0xE30 offset Flow calculating revise FE.43...
  • Page 29 SI30 Solar Pump Inverter Manual Solar array C-08 0.1V Read only 2108H voltage(DC) AC/DC switching C-09 Read only 2109H status C-10 Output power 0.01kw Read only 210AH C-11 DC bus voltage 0.1V Read only 210BH C-29 Output power factor -1.00~1.00 Read only 211BH C-30...
  • Page 30: Chapter 6 Operation Guidance

    SI30 Solar Pump Inverter Manual Chapter 6 Operation Guidance 6.1 AM Motor Pump Drive Operation Guidance (Keyboard as an example) 1) Wiring: a. Confirmed the solar pump drive if matching with motor. b. Correctly connect “+”“-” of solar panel to correspond “+”“-” pole of inverter or P1, N1 wiring terminals of AC/DC module.
  • Page 31 SI30 Solar Pump Inverter Manual demand. b). Set motor (pump) parameters according to nameplate of pump. Then Set F5.12 =1, and the keypad will show T-00.Press FWD to start motor auto tuning. This process takes about three minutes; Note: 1. If you can disconnect the motor and load, self-learning would be better; 2.The self-learning need to be done with enough sunshine and when the solar panels can provide enough energy.
  • Page 32 SI30 Solar Pump Inverter Manual after FE.19 (dry run protection automatic recovery) time, automatically resume to running state; D. Over-current Protection During the operation of the photovoltaic pump, for some reason, the output current is greater than FE.20(Over current protection detection current), and after FE.21 (Over current protection detection time) time, enters into standby protection state, while the keyboard warning "...