Download Print this page

Veichi AC10 Series Technical Manual page 126

Advertisement

Parameter details
11.6 F04 Group: V/F Control
F04.0x Group: V/F control
V/F pressure frequency curve
F04.00: VF curve selection
Code (Addr.)
Name
F04.00
(0x0400)
VF curve selection
STOP
0: straight line VF curve
1-9: respectively, the torque curve of the power of 1.1-1.9 VF
10: square VF curve
11: Custom VF curve
Note:
F04.00 = 11 [VF curve selection = custom VF curve], set by F04.0x.
The straight line and the torque reduction curve are as follows. The torque reduction VF curve is valid above 0.3 times the rated motor frequency.
Torque boost
F04.01: Torque boost
Code (Addr.)
Name
F04.01
(0x0401)
Torque boost
RUN
0.0: Automatic torque boost to compensate for losses on the stator resistance.
Other values: fixed torque boost
Note:
When F04.01 = 0.0 [torque boost = automatic torque boost], the accurate stator resistance value is obtained by F02.07=3 self-learning, but the
motor output is in the best state.
The schematic diagram of the fixed torque boost under the V/F curve line and curve is as follows.
Output
voltage
Motor
rated
voltage
Torque
boosting
voltage
0
Torque boost
cutoff frequency
Fixed torque lifting diagram
AC10 Series Frequency Inverter Technical Manual
Content
V/F
Set the VF curve
Output voltage
Straight line VF curve
(constant torque)
0
30% rated motor frequency
VF line and torque reduction curve
Content
V/F
Set torque boost
Output
frequency
Motor rated
frequency
Motor rated voltage
Torque reduction
curve
frequency
Motor rated frequency
Output
voltage
Motor
rated
voltage
Torque
boosting
voltage
0
Torque boost
cutoff frequency
122
Factory setting
(Setting range)
0
(0 ~ 11)
Output
Factory setting
(Setting range)
随机型
(0.0 ~ 30.0%)
Output
frequency
Motor rated
frequency

Advertisement

loading

This manual is also suitable for:

Sis series