Veichi AC10 Series Technical Manual page 73

Advertisement

(0x0337)
selection
RUN
F03.56
Torque
(0x0338)
maximum speed limit
RUN
F03.57
Torque control anyway maximum
(0x0339)
speed limit
RUN
F03.58
Given
torque
(0x033A)
frequency
RUN
F03.59
(0x033B)
Given torque gain
RUN
10.8 Group F04: V/F Control
F04.0x group: V/F control
Parameter
(address)
Name
djustable
attribute
F04.00
(0x0400)
Linear VF curve selection
STOP
F04.01
(0x0401)
Torque boost
RUN
F04.02
(0x0402)
Torque boost cutoff frequency
RUN
F04.03
(0x0403)
Slip compensation gain
RUN
F04.04
(0x0404)
Slip compensation limit
RUN
F04.05
(0x0405)
Slip compensation filter time
RUN
F04.06
(0x0406)
Oscillation suppression gain
RUN
F04.07
(0x0407)
Oscillation suppression filter time
RUN
F04.08
(0x0408)
Output voltage percentage
STOP
F04.1x group: Custom V/F curve
Parameter
(address)
Name
djustable
attribute
0: Function code F03.57 is set;
1: Integrated keyboard potentiometer given × F03.57;
2: AI × F03.57;
3: Reserved;
4: Reserved
5: PUL× F03.57;
6: RS485 communication given × F03.57
7: Reserved
control
forward
speed
SVC
Set the torque control forward maximum speed limit.
SVC
Set the torque control reverse maximum speed limit.
gain
switching
SVC
Set the given torque gain switching frequency.
SVC
Set the given torque gain.
Content
V/F
Used to select the type of V/F curve to meet different load features.
0: Straight line VF curve;
1-9: Respectively, a power VF curve of 1.1-1.9;
10: Square VF curve;
11: Custom VF curve;
V/F
0.0%: automatic torque boost
0.1~30.0%: manual torque boost
V/F
Set the effective range of the torque boost function. When the
output frequency exceeds this value, the torque boost function is
cut off.
V/F
Set the slip compensation gain.
V/F
Set the slip compensation limit value.
V/F
The slip compensation function needs to correctly input the motor
nameplate parameters and learn the parameters to achieve the
best results.
V/F
By adjusting this value, low frequency resonance can be
suppressed, but not too large; otherwise it will cause additional
stability problems.
V/F
Set the oscillation suppression filter time.
V/F
Set the output voltage percentage.
Content
69
(0 ~ 7)
100.0%s
(0.0~100.0%)
100.0%s
(0.0~100.0%)
2.00Hz
(0.00 ~ 50.00Hz)
100.0%
(0.0 ~ 500.0%)
Factory
(setting range)
0
(0 ~ 11)
0.0%
(0.0 ~ 30.0%)
100.0%
(0.0 ~ 100.0%)
0.0%
(0.0 ~ 200.0%)
100.0%
(0.0 ~ 300.0%)
0.200
(0.000 ~ 6.000)
100.0%
(0.0 ~ 900.0%)
1.0s(0.0 ~ 100.0s)
100.0%
(25.0~120.0%)
Factory default
(setting range)
AC10 Series Frequency Inverter Technical Manual
Function Table