Function Table
F06.76
(0x064C)
vY3 output OFF delay time
RUN
F06.77
(0x064D)
vY4 output OFF delay time
RUN
10.11 Group F07: Operation Control
F07.0x group: Start control
Parameter
(address)
Name
djustable
attribute
F07.00
(0x0700)
Start mode
STOP
F07.01
(0x0701)
Start pre-excitation time
STOP
F07.02
(0x0702)
Starting frequency
STOP
F07.03
(0x0703)
Start protection selection
STOP
F07.05
(0x0705)
Direction of rotation
STOP
F07.06
(0x0706)
Power failure restart action selection
STOP
F07.07
(0x0707)
Power failure restart waiting time
STOP
F07.1x group: Shutdown control
Parameter
(address)
Name
djustable
attribute
F07.10
(0x070A)
Stop mode
RUN
AC10 Series Frequency Inverter Technical Manual
V/F SVC
V/F SVC
Content
V/F SVC
0: Started by the start frequency
1: DC braking first starts again from the starting
frequency
2: Start after the speed tracking and direction
judgment
V/F SVC
Just asynchronous machine vector control (no
PG) supports pre-excitation, others would be
ignored
V/F SVC
When the given frequency is less than this value,
it does not start and is in standby state.
V/F SVC
0: Off 1: On
LED "0" digit: Terminal start protection when
exiting abnormal
LED "00" digit: Jog terminal start protection when
exiting abnormal
LED "000" digit: Terminal start protection when
the command channel is switched to the terminal
LED "0000" digit: Reserved
Note: The terminal start protection is enabled by
default when the free stop, emergency stop and
forced stop commands are valid.
V/F SVC
LED "0" digit: Reverse the running direction
0: The direction is unchanged
1: Direction reversal
LED "00" digit: No direction of operation
0: Allow forward and reverse commands
1: Only forward commands are allowed
2: Only reverse command is allowed
LED "000" digit: Frequency Control Command
Direction
0: The frequency control direction is invalid.
1: Frequency control direction is valid
LED "0000" digit: Reserved
V/F SVC
0: Invalid
1: Valid
V/F SVC
Content
V/F SVC
0: Deceleration stop
1: Free stop
78
0.010s
(0.000~60.000s)
0.010s
(0.000~60.000s)
Factory
default
Notes
(setting
range)
S/T2 models do
0
not
support
(0 ~ 2)
speed tracking
S/T2 models do
0.00s
not
support
(0.00~60.00s)
starting
pre-
excitation
0.50Hz
(0.00~Upper
limit
frequency
digital setting)
0111
(0000~1111)
0000
(0000~1111)
0
(0 ~ 1)
0.50s
(0.00~60.00s)
Factory default
(setting range)
0
(0 ~ 1)