Download Print this page

Veichi AC10 Series Technical Manual page 175

Advertisement

Ten digits: Monitoring parameter number Cxx.yy, yy setting 00~63
Hundreds of thousands: monitoring parameter number Cxx.yy xx set 00~07
Note:
The parameter [F11.15-F11.18] is only valid for the two-line keyboard. The two-line keyboard switches between the display parameters 1-4 of
the second line of the k
The single-line keyboard switches the keyboard display parameters 1-4 in sequence by long pressing the "SET" button (the two-line keyboard
content of "Display Parameter 1" is displayed by default.
F11.2x group: monitoring parameter control
F11.20: Keyboard display item settings
Code (Addr.)
Name
F11.20
Keyboard display item
(0x0B14)
settings
RUN
Unit digit: Output frequency display selection
0: Target frequency Displays the target frequency of the currently controlled motor
1: Running frequency Shows the output frequency after the drive is operated.
2~F: target frequency filtering, the larger the value, the deeper the filtering
Ten: reserved
0: invalid
1: Active power to remove stator resistance loss
Hundreds: Power Display Dimensions
0: Power display percentage (%) Display output power is 100%, 100.0% bit motor rated power
1: Power display kilowatt (KW) display output power actual value
Thousands: reserved
F11.21: Speed display factor
Code (Addr.)
Name
F11.21
(0x0B15)
Speed display factor
RUN
F11.22: Power display factor
Code (Addr.)
Name
F11.22
(0x0B16)
Power display factor
RUN
Note:
Correct C-10 output power value
F11.23 monitoring parameter group display selection
Code (Addr.)
Name
F11.23
Monitoring parameter
(0x0B17)
group display selection
RUN
F11.24: Monitoring parameter filtering selection
Code (Addr.)
Name
F11.24
Monitoring parameter
(0x0B18)
filtering selection
RUN
F11.25: Display selection when the motor is self-learning
Content
V/F SVC
Content
V/F SVC
This parameter sets the display coefficient of the "mechanical speed" of the
keyboard monitor item, and 100.0% corresponds to the rated motor speed.
Content
V/F SVC
This parameter sets the display coefficient ratio of the keyboard monitor
"output power"
Content
V/F SVC
Unit: Reserved
Ten: C05 display selection
0, 1: VF mode related parameters
2: VC mode related parameters
Hundreds place: C00.40~C00.63 display selection
0: invalid
1: valid
Thousands: reserved
Content
V/F SVC
Unit: Output current display filter
0~F: the larger the value, the deeper the filter
Ten: reserved
Hundreds: reserved
Thousands: reserved
171
Parameter details
wer-off and memory function. After power-on, the
Factory setting
(Setting range)
0000
(0000~1112)
Factory setting
(Setting range)
100.0%
(0.0 ~ 500.0%)
Factory setting
(Setting range)
100.0%
(0.0 ~ 500.0%)
Factory setting
(Setting range)
0000
(0000~FFFF)
Factory setting
(Setting range)
0x0000
(0x0000 ~0x 000F)
AC10 Series Frequency Inverter Technical Manual

Advertisement

loading

This manual is also suitable for:

Sis series