Function Table
F01.21
(0x0115)
Acceleration time unit
STOP
F01.22
(0x0116)
Acceleration time 1
RUN
F01.23
(0x0117)
Deceleration time 1
RUN
F01.24
(0x0118)
Acceleration time 2
RUN
F01.25
(0x0119)
Deceleration time 2
RUN
F01.26
Acceleration time 3
(0x011A)
RUN
F01.27
(0x011B)
Deceleration time 3
RUN
F01.28
(0x011C)
Acceleration time 4
RUN
F01.29
(0x011D)
Deceleration time 4
RUN
F01.30
S
curve
(0x011E)
deceleration selection
STOP
F01.31
(0x011F)
Acceleration start S curve time
STOP
F01.32
(0x0120)
Accelerated end S curve time
STOP
F01.33
(0x0121)
Deceleration start S curve time
STOP
F01.34
(0x0122)
Deceleration end S curve time
STOP
F01.35
Acceleration
(0x0123)
acceleration time 2 switching
RUN
frequency
F01.4x group: PWM control
Parameter
(address)
Name
djustable
attribute
F01.40
(0x0128)
Carrier frequency
RUN
AC10 Series Frequency Inverter Technical Manual
V/F SVC
The unit of acceleration time setting.
0: 1s
1: 0.1s
2: 0.01s
V/F SVC
The time required for the output frequency to accelerate from 0.00 Hz to
the time reference frequency.
1 to 65000 s (F01.21 = 0)
0.1 to 6500.0 s (F01.21 = 1)
0.01 to 650.00 s (F01.21 = 2)
V/F SVC
The time it takes for the output frequency to decelerate from the time
reference frequency to 0.00 Hz.
V/F SVC
The time required for the output frequency to accelerate from 0.00 Hz to
the time reference frequency.
V/F SVC
The time it takes for the output frequency to decelerate from the time
reference frequency to 0.00 Hz.
V/F SVC
The time required for the output frequency to accelerate from 0.00 Hz to
the time reference frequency.
V/F SVC
The time it takes for the output frequency to decelerate from the time
reference frequency to 0.00 Hz.
V/F SVC
The time required for the output frequency to accelerate from 0.00 Hz to
the time reference frequency.
V/F SVC
The time it takes for the output frequency to decelerate from the time
reference frequency to 0.00 Hz.
V/F SVC
acceleration
and
S curve acceleration and deceleration selection is valid
0: Invalid 1: Valid
V/F SVC
Set the acceleration start S curve time.
V/F SVC
Set the acceleration end S curve time.
V/F SVC
Set the deceleration start S curve time.
V/F SVC
Set the deceleration end S curve time.
time
1
and
V/F SVC
Set the acceleration time 1 and acceleration time 2 to switch the frequency.
Content
V/F SVC
Used to set the switching frequency of the drive IGBT.
64
2
(0 ~ 2)
Model setting
(0.01
~
650.00s)
Model setting
(0.01~650.00
s)
Model setting
(0.01~650.00
s)
Model setting
(0.01~650.00
s)
Model setting
(0.01~650.00
s)
Model setting
(0.01~650.00
s)
Model setting
(0.01~650.00
s)
Model setting
(0.01~650.00
s)
1
(0~1)
0.20s
(0.00~10.00)
0.20s
(0.00~10.00)
0.20s
(0.00~10.00)
0.20s
(0.00~10.00)
0.00Hz
(0.00~Maxim
um
frequency)
Factory default
(setting range)
4.0 kHz
(1.0~16.0kHz)