3: Difference between torque reference channel A and channel source B (A-B)
4: Maximum value of both torque reference channel A and channel B
5: Minimum value of torque given channel A and channel B
Thousands: reserved
F03.42: Torque digital setting
Code (Addr.)
Name
F03.42
(0x032A)
Torque digital setting
RUN
Note:
The set value 100% corresponds to the rated motor torque.
F03.43: Torque input lower limit value
Code (Addr.)
Name
F03.43
(0x032B)
Torque input lower limit
RUN
Code (Addr.)
Name
F03.44
Torque
lower
(0x032C)
corresponding setting
RUN
Note: The set value 100% corresponds to the rated motor torque.
F03.45: Torque input upper limit value
Code (Addr.)
Name
F03.45
Torque input upper
(0x032D)
limit
RUN
F03.46: Torque upper limit setting
Code (Addr.)
Name
F03.46
Torque
upper
(0x032E)
setting
RUN
Note: The set value 100% corresponds to the rated motor torque.
F03.47: Torque filter time
Code (Addr.)
Name
F03.47
(0x032F)
Torque filtering time
RUN
Applying filtering to the torque command signal reduces the vibration caused by the torque command signal. The interference and adjustment of the
removal torque command signal is effective with the responsiveness of the command controller.
If vibration occurs using torque control, increase the set value. However, if the setting is too large, the responsiveness will deteriorate.
F03.52: Maximum torque command
Code (Addr.)
Name
F03.52
Torque
command
(0x0334)
upper limit
RUN
F03.53: Lower torque command limit
Code (Addr.)
Name
F03.53
Torque
command
(0x0335)
lower limit
RUN
AC10 Series Frequency Inverter Technical Manual
Content
SVC
Set torque digital setting
Content
SVC
Set the torque input lower limit
Content
limit
SVC
Set the lower limit corresponding setting
Content
SVC
Set the torque input upper limit
Content
limit
SVC
Set the upper limit corresponding setting
Content
SVC
Set the torque reference filter time
Content
SVC
Set the upper limit of the torque command
Content
SVC
Set the torque command lower limit
120
Factory setting
(Setting range)
0.0%
(0.0 ~ 100.0%)
Factory setting
(Setting range)
0.00%
(0.00 ~ 100.00%)
Factory setting
(Setting range)
0.00%
(-200.00 ~ 200.00%)
Factory setting
(Setting range)
100.00%
(0.00 ~ 100.00%)
Factory setting
(Setting range)
100.00%
(-200.00 ~ 200.00%)
Factory setting
(Setting range)
0.100s
(0.000 ~ 6.000s)
Factory setting
(Setting range)
150.0%
(0.0 ~200.0%)
Factory setting
(Setting range)
0.0%
(0.0 ~ 200.0%)