Download Print this page

Veichi AC10 Series Technical Manual page 115

Advertisement

Code (Addr.)
Name
F01.28
(0x011C)
Acceleration time 4
RUN
F01.29
(0x011D)
Deceleration time 4
RUN
S curve selection
The S-curve feature allows the machine to be smoothly started and stopped, reducing the impact on the load.
Set the S-curve characteristic time at the start of acceleration/deceleration and at the end of acceleration/deceleration as needed.
This function is enabled by F01.30=1[S Curve Selection=Enabled].
The S curve characteristics when running switching (forward/reverse) are as shown in the figure below.
Forward
run
Reverse
run
Output
frequency
Schematic diagram of S curve
Note:
After setting the S-curve characteristic, the acceleration/deceleration time will increase the acceleration/deceleration time as shown below.
Acceleration time = selected acceleration time + ([F01.31]+[F01.32])/2
Deceleration time = selected deceleration time + ([F01.33]+[F01.34])/2
Code
Name
(Addr.)
F01.30
(0x011E)
S curve selection
STOP
Note: The jog S curve is set by F07.33 [Jog S curve selection].
0: invalid
1: valid
Code
Name
(Addr.)
F01.31
Acceleration
(0x011F)
curve time
STOP
Code
Name
(Addr.)
F01.32
Accelerated end S curve
(0x0120)
time
STOP
4
Content
V/F SVC
Set the value of acceleration time 4
V/F SVC
Set the value of deceleration time 4
ON
F01.32
F01.33
F01.31
F01.34
Content
V/F SVC
Select whether the S curve function is on
Content
start
S
V/F SVC
Set acceleration start S curve time
Content
V/F SVC
Set the acceleration end S curve time
OFF
ON
F01.31
F01.32
111
Parameter details
Factory setting
(Setting range)
With power level
(Change with F01.21)
With power level
(Change with F01.21)
OFF
F01.34
F01.33
Factory setting
(Setting range)
1
(0 ~ 1)
Factory setting
(Setting range)
0.20
(0.01 ~ 10.00s)
Factory setting
(Setting range)
0.20
(0.01 ~ 10.00s)
AC10 Series Frequency Inverter Technical Manual