Function Table
F05.73
Curve 2 inflection point 1 corresponding
(0x0549)
setting
RUN
F05.74
(0x054A)
Curve 2 inflection point 2 input voltage
RUN
F05.75
Curve 2 inflection point 2 corresponding
(0x054B)
setting
RUN
F05.76
(0x054C)
Curve 2 upper limit
RUN
F05.77
Curve 2 upper limit corresponding
(0x054D)
setting
RUN
F05.8x group: AI as a digital input terminal
Parameter
(address)
Name
djustable
attribute
F05.80
AI port to do digital input terminal feature
(0x0550)
selection
RUN
F05.81
(0x0551)
AI terminal function selection (as X)
STOP
F05.82
(0x0552)
AI high level setting
RUN
F05.83
(0x0553)
AI low level setting
RUN
10.10 Group F06: Output Terminal
F06.0x group: AO (analog) output
Parameter
(address)
Name
djustable
attribute
F06.00
(0x0600)
AO output mode selection
RUN
AC10 Series Frequency Inverter Technical Manual
V/F SVC
Corresponding set percentage
V/F SVC
Set curve 2 inflection point 2 input voltage
V/F SVC
Corresponding set percentage
V/F SVC
Set the upper limit of curve 2
V/F SVC
Corresponding set percentage
Content
V/F SVC
0: Active low 1: Active high
LED "0" digit: AI
LED "00" digit: Reserved
LED "000" digit: Reserved
LED "0000" digit: Reserved
V/F SVC
See X terminal function
V/F SVC
The input setting is greater than the high level setting, which is the
input high level.
V/F SVC
Less than the low level setting is low.
Content
V/F SVC
0: 0~10V
1: 4.00~20.00mA
2: 0.00~20.00mA
3: FM high-speed pulse output
Note: 5.5kW and below power models do not support high-speed
pulse output, selected invalid
74
30.00%
(0.00~100.00%)
60.0%
(0.0 ~ 100.0%)
70.00%
(0.00~100.00%)
100.00%
(0.00~100.00%)
100.0%
(0.0 ~ 100.0%)
Factory default
(setting range)
0000
(0000 ~ 1111)
0
(0~63)
70.00%
(0.00~100.00%)
30.00%
(0.00~100.00%)
Factory default
(setting range)
0
(0 ~ 4)