Veichi AC10 Series Technical Manual page 145

Advertisement

PID feedback sensor disconnection
19
Meter length arrives
20
Timer time to
21
Counter reaches maximum
22
Counter reaches the set value
23
Energy consumption braking
24
Reserved
25
Emergency stop
26
Overload pre-alarm output 1
27
Underload pre-alarm output 2
28
Drive warning
29
Communication address 0x3018 control output
30
Drive overheat warning
31
Motor overheat alarm output
32
Reserved
33
Run pause output (module blocked)
34
Torque limit
35
Speed limit
36
Comparator 1
37
Comparator 2
38
Reserved
39
Reserved
40~47
Reserved
48~63
No. 30 output terminal function: MODBUS RS485 communication control multi-function output function selection, write value to BIT0~BIT1 in
communication address 0x3018, output terminal corresponding to controller. The specific correspondence is as follows:
Mailing address
0x3018
-function output terminal polarity selection
Code
Name
(Addr.)
F06.20
Output
terminal
(0x0614)
function selection
RUN
Unit position: Y terminal
0: Positive polarity Active state Y output terminal low level, equivalent normally open
1: Negative polarity Effective state Y output terminal has no output, equivalent normally open
Tens place: relay 1 output terminal
0: Positive polarity TA-TC is normally open, TB-TC is normally closed
1: Negative polarity TA-TC normally closed, TB-TC normally open
Hundreds: reserved
Thousands: reserved
F06.21: Output terminal Y function selection
Code
Name
(Addr.)
F06.21
Output
terminal
(0x0615)
function selection
RUN
F06.22: Relay 1 function selection
Name
BIT0: corresponding output terminal Y
BIT1: Corresponding relay 1 output (TA-TB-TC)
Content
Y
V/F SVC
Setting the function of the multi-function output terminal Y
Content
Y
V/F SVC
Setting the function of the multi-function output terminal Y
141
Refer to the F13.25 parameter description
Reserved
Reserved
Reserved
Reserved
Energy consumption braking starting voltage, refer to F10.15 parameter
description
Refer to F02.32, F02.38 parameter description
Refer to F10.32 parameter description
Refer to F10.32 parameter description
Reference form
Refer to the F10.25 parameter description
Refer to F10.26 parameter description
Refer to F06.4x Monitoring Parameter Comparator Output 1
Refer to F06.4x Monitoring Parameter Comparator Output 2
The terminal does not operate.
The output is judged according to the operating state of the drive.
AC10 Series Frequency Inverter Technical Manual
Parameter details
Factory setting
(Setting range)
0000
(0000 ~ 0x1111)
Factory setting
(Setting range)
1
(0 ~ 63)

Advertisement

loading

This manual is also suitable for:

Sis series