F05.5x group: Analog (AI) linear processing
Parameter
(address)
Name
djustable
attribute
F05.50
(0x0532)
AI lower limit
RUN
F05.51
(0x0533)
AI lower limit corresponding setting
RUN
F05.52
(0x0534)
AI upper limit
RUN
F05.53
(0x0535)
AI upper limit corresponding setting
RUN
F05.54
(0x0536)
AI filter time
RUN
F05.6x group: AI curve 1 processing
Parameter
(address)
Name
djustable
attribute
F05.60
(0x053C)
Curve 1 lower limit
RUN
F05.61
Curve 1 lower limit corresponding
(0x053D)
setting
RUN
F05.62
(0x053E)
Curve 1 inflection point 1 input voltage
RUN
F05.63
Curve 1 inflection point 1 corresponding
(0x053F)
setting
RUN
F05.64
(0x0540)
Curve 1 inflection point 2 input voltage
RUN
F05.65
Curve 1 inflection point 2 corresponding
(0x0541)
setting
RUN
F05.66
(0x0542)
Curve 1 upper limit
RUN
F05.67
Curve 1 upper limit corresponding
(0x0543)
setting
RUN
F05.7x group: AI curve 2 processing
Parameter
(address)
Name
djustable
attribute
F05.70
(0x0546)
Curve 2 lower limit
RUN
F05.71
Curve 2 lower limit corresponding
(0x0547)
setting
RUN
F05.72
(0x0548)
Curve 2 inflection point 1 input voltage
RUN
Content
V/F SVC
Define the signal received by the terminal. The voltage signal
below this value is processed by the limit value.
V/F SVC
Set the percentage of the corresponding set value
V/F SVC
Define the signal received by the terminal. The voltage signal
above this value is processed according to the upper limit value.
V/F SVC
Set the percentage of the corresponding set value
V/F SVC
Defines the size of the analog signal to be used to eliminate
interfering signals.
Content
V/F SVC
Set the lower limit of curve 1
V/F SVC
Corresponding set percentage
V/F SVC
Set curve 1 inflection point 1 input voltage
V/F SVC
Corresponding set percentage
V/F SVC
Set curve 1 inflection point 2 input voltage
V/F SVC
Corresponding set percentage
V/F SVC
Set the upper limit of curve 1
V/F SVC
Corresponding set percentage
Content
V/F SVC
Set the lower limit of curve 2
V/F SVC
Corresponding set percentage
V/F SVC
Set curve 2 inflection point 1 input voltage
73
Factory default
(setting range)
0.0%
(0 0.0~100.0%)
0.0%
(-100.0~100.0%)
100.00%
(0.00~100.00%)
100.0%
(0.00~100.0%)
0.010s
(0.000~6.000s)
Factory default
(setting range)
0.0%
(0.0 ~ 100.0%)
0.0%
(0.0 ~ 100.0%)
30.0%
(0.0 ~ 100.0%)
30.00%
(0.00~100.00%)
60.0%
(0.0 ~ 100.0%)
70.00%
(0.00~100.00%)
100.00%
(0.00~100.00%)
100.0%
(0.0 ~ 100.0%)
Factory default
(setting range)
0.0%
(0.0~100.0%)
0.0%
(0.0~100.0%)
30.0%
(0.0~100.0%)
AC10 Series Frequency Inverter Technical Manual
Function Table