Installation and Wiring
Standard PNP Connection Diagram
R
AC
power
S
input
T
Multi Function
contact input
Frequency
control input
Note:
Note:
1. Please select the appropriate braking resistor according to the site working conditions and the 《Braking Resistor Specification Parameters》.
2. The multi-function input terminals (X1 to X4/PUL) can support NPN transistor signals as inputs.
3. The analogue monitoring output is a dedicated output for indicator meters such as ammeters and voltmeters, and should not be used for control
operations such as feedback control.
4. As there are several pulse types in practice, please see the detailed description for the specific wiring.
5. For 0.4kW to 5.5kW drives, the COM and GND terminals are two-in-one function terminals and are combined externally as GND terminals; for
7.5kW to 22kW drives, both COM and GND terminals are available.
AC10 Series Frequency Inverter Technical Manual
Breaker
Contactor
Input reactor
R
S
T
Note 5
(Run forward)
X1
(Run reverse)
X2
(Jog forward)
X3
(Jog reverse)
X4
24 V
GND/ COM
A +
RS485 differential
communication
120O
B -
Note:The solid mark in the box is the
factory default value of the inverter
X4
Pulse input
PUL
Twisted pair shielded cable
(near the inverter end grounded)
+ 10 V
Voltage / current type
I
analog input
AI
U
GND
1 , +10 V port maximum output:50mA
2 , AI port internal resistance:75 KΩ
AC10—7.5KW~22KW Standard wiring diagram for power products
Braking resistor
R
Output reactor
P
PB
U
V
W
VFD
+24
PLC
E
COM
AC 220V
TA
Coil
TB
TC
S3
+24V
Y
GND / COM
Note :
1 、 +24V port max output DC 24 V /100 mA
2 、 Y port max output
(near the inverter end grounded)
S1
S2
U
I
AO
S4
GND
Note:AO port as voltage type
Maximum output when signal output:2mA
Scale:Symbol
Symbol
14
U
V
M
~
W
Shielded cable or armored cable(near the inverter
terminal ground)
(grounding resistance is less than 10 Ohms)
Maximum output
of the contact :
Passive contact
output
3A/240 VAC
5A/ 30 VDC
AC 0V
Coil
Twisted pair shielded cable near the
inverter end grounded
Collector
open state output
DC 24 V/ 50 mA
Twisted pair shielded cable
Analog monitor
5
_
signal output
V
-
+
represents the main curcuit terminal
represents control curcuit terminal

Advertisement