Parameter details
Terminal 3
Terminal 2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
Note:
Active current component: can be sent through the Flextronics CAN host, RS485 communication address is 0x3011.
Code (Addr.)
Name
F13.01
Keyboard digital PID
(0x0D01)
given / feedback
RUN
This parameter is valid only when [F13.00]/[F13.03] is set to keyboard digital PID reference/feedback; after this parameter is changed, the PID reference
value in the monitoring object is automatically modified synchronously.
If the parameter [F11.04] LED is set to "2", the value of this parameter can be quickly modified by the keyboard up and down keys. After the parameter is
quickly modified, the drive saves the modified value when the power is off by [F11. 04] The setting value of the LED ten digits is determined.
Code (Addr.)
Name
F13.02
(0x0D02)
PID given change time
RUN
PID given change time:
Refers to the time required for the PID setting percentage to change from 0.0% to 100.0%; when the PID given changes, the PID reference value changes
linearly according to the given change time, which reduces the adverse effect on the system caused by the given mutation.
Code (Addr.)
Name
F13.03
PID
(0x0D03)
feedback
RUN
source
Set the input channel of the PID controller feedback signal.
0: keyboard digital PID to feedback
The PID feedback channel is determined by the set value of [F13.01].
1: reserved
2: Voltage/current analog AI feedback
The PID feedback channel is the voltage/current analog AI1.
3: Reserved
4: Reserved
5: terminal pulse PUL feedback
The PID feedback channel is the terminal pulse PUL.
6: RS485 communication feedback
The PID feedback channel is RS485 communication.
7: Reserved
8: Terminal selection
The PID feedback channel is selected by a combination of multi-function input terminals, and the multi-function input terminal is set by [F05.00~F05.09].
9: Local active current
Terminal switching selection diagram:
Terminal 3
Terminal 2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
Note:
The PID controller given signal source and the PID controller feedback signal source cannot be set to the same channel; otherwise the PID
will not work normally.
F13.04: Feedback signal low pass filtering time
AC10 Series Frequency Inverter Technical Manual
Terminal 1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Content
V/F SVC
Used to set the keyboard digital PID reference/feedback value
Content
V/F SVC
Used to set the PID given change time
Content
controller
V/F SVC
signal
Used to set the PID controller feedback signal source
Terminal 1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
PID given switching terminal selection
Keyboard digital PID given
Reserved
Voltage / current analog AI1 given
Voltage/current analog quantity AI2 given
Reserved
Terminal pulse PUL given
RS485 communication given
Option card
PID given switching terminal selection
Keyboard digital PID feedback
Reserved
Voltage/current analog AI1 feedback
Voltage/current analog AI2 feedback
Reserved
Terminal pulse PUL feedback
RS485 communication feedback
Option card
176
Factory setting
(Setting range)
50.0%
(0.0~100.0%)
Factory setting
(Setting range)
1.00s
(0.00~60.00s)
Factory setting
(Setting range)
2
(0~9)