F00.00
(0x0000)
Parameter access level
RUN
0: standard parameter
Accessible parameter group (Fxx group) and monitoring parameters (Cxx group)
1: Common parameters (F00.00, Pxx.yy)
Only access the parameter code set in F00.00 parameter, F00.10~F00.39 [common parameters 1~30]
2: Monitoring parameters (F00.00, Cxx.yy)
Can only access F00.00 parameters, monitoring group parameters
3: The parameter has been changed (F00.00, Hxx.yy)
Can only access F00.00 parameters, different parameters from the factory defaults
Note:
When F11.00 [key lock selection] and F11.01 [key lock password] set the lock password to the drive, the keyboard cannot change the corresponding
parameters.
F00.01: Use selection
Code
Name
(Addr.)
F00.01
(0x0001)
Use choice
STOP
The drive sets the dedicated preset settings for the purpose shown in the table below. For F00.01, the drive will automatically set the parameters related
to the application to the optimal value. The parameters to be adjusted frequently will be saved to F00.10~F00.39 [Common Parameters 1~30] for quick
setting and reference.
0: general purpose machine (G type machine)
1: reserved
Note:
After setting F00.01, initialize the parameters with F00.03 = 11, 22 [Initialization = Initialization Mode 1, 2], and F00.30~F00.39 will be reset with the
parameterized initialization operation.
0: general purpose machine (G type machine)
The initialization values of the following common parameter codes.
Table 11.1 Common Parameter Initialization Settings
Common parameter code
F00.10
F00.11
F00.12
F00.13
F00.14
F00.15
F00.16
F00.17
F00.18
F00.19
F00.20
F00.21
F00.22
F00.23
F00.24
F00.25
F00.26
F00.27
F00.28
F00.29
The initialization values of the following common parameter codes are related to the F00.01 setting.
Table 11.2 Common Parameter Initialization Settings
Common parameter code
F00.30
V/F SVC
Set the parameter access level based on the case of restricted
parameter access.
Content
V/F SVC
Set the drive for the purpose.
Setting parameter code
F01.00
F01.01
F01.02
F07.10
F01.22
F01.23
F01.10
F01.12
F01.40
F07.30
F02.01
F02.02
F02.03
F02.04
F02.05
F02.06
F02.07
F12.01
F12.02
F12.03
Setting parameter code
F07.00
101
0
(0 ~ 3)
Factory setting
(Setting range)
0
(0 ~ 1)
Name
Control method selection
Run command given channel
Frequency given channel
Stop mode
Acceleration time 1
Deceleration time 1
Maximum frequency
Upper limit frequency
Carrier frequency
Jog frequency
Number of motor poles
Motor rated power
Motor rated frequency
Motor rated speed
Motor rated voltage
Motor rated current
Motor parameter auto-tuning selection
ModBus address
Communication baud rate
Communication data format
Name
Startup mode
AC10 Series Frequency Inverter Technical Manual
Parameter details