Download Print this page

Veichi AC10 Series Technical Manual page 90

Advertisement

Function Table
F10.51
(0x0A33)
Failure self-recovery interval
STOP
F10.52
(0x0A34)
Numbers of failures recovered
STOP
10.15 Group F11: Operator Parameters
F11.0x group: Button operation
Parameter
(address)
Name
djustable attribute
F11.00
(0x0B00)
Key lock selection
RUN
F11.01
(0x0B01)
Key lock password
RUN
F11.02
Keyboard
(0x0B02)
selection
STOP
F11.03
(0x0B03)
Keyboard STOP button settings
STOP
F11.04
Status interface up and down
(0x0B04)
keys (knob) function selection
STOP
F11.05
Up and down keys to quickly
(0x0B05)
change the parameter code
RUN
setting
AC10 Series Frequency Inverter Technical Manual
is turned off; otherwise it indicates that the function is enabled.
V/F SVC
Set the waiting time before the drive resets to the time before
each reset.
V/F SVC
Indicates the number of self-recovery faults that have been
performed. This parameter is a read-only parameter.
Content
V/F SVC
0: Not locked
1: Keyboard function parameter modification lock
2: Function parameters and non-start stop button lock
3: Function parameters and button full lock
V/F SVC
V/F SVC
0: Invalid
1: Reverse run key
2: Forward jog operation key
3: Reverse jog run key
multi-function
key
4: Keyboard command channel and terminal naming channel switch
5: Keyboard command channel and communication naming channel
switch
6: Terminal command channel and communication naming channel
switch
7: Keyboard, terminal, communication command channel cycle
switching
V/F SVC
0: Non-keyboard control mode is invalid
1: Non-keyboard control mode stops according to stop mode
2: Non-keyboard control mode stops in free mode
V/F SVC
LED "0" digit: Keyboard up and down keys to modify the selection
0: Invalid
1: Used to adjust the frequency keyboard given F01.09
2: Used to adjust the PID keyboard given F13.01
3: Keyboard up and down keys to modify the parameter number
setting
LED "00" digit: Power-down storage
0: Frequency is not stored when power is off
1: Frequency power down storage
LED "000" digit: Action Limit
0: Adjustable operation stop
1: Adjustable only during operation, stop and keep
2: Adjustable during operation, stop and clear
LED "0000" digit: Reserved
V/F SVC
LED "0" and "00" digit: yy setting in function parameter number
Fxx.yy
00~99
LED "000" and "0000" digit: xx setting in function parameter number
Fxx.yy
00~15
86
1.0s
(0 ~100.0)
0
Factory default
(setting range)
0
(0 ~ 3)
0
(0 ~ 65535)
1
(0 ~ 7)
0
(0 ~ 2)
0011
(0000~0213)
0109
(0000 ~ 1563)

Advertisement

loading

This manual is also suitable for:

Sis series