Veichi AC10 Series Technical Manual page 131

Advertisement

37
Swing frequency reset
38
Keyboard button and display self-test selection
39
X4 frequency measurement
Code (Addr.)
Name
F05.00
Terminal X1 function
(0x0500)
selection
STOP
Code (Addr.)
Name
F05.01
Terminal X2 function
(0x0501)
selection
STOP
Code (Addr.)
Name
F05.02
Terminal X3 function
(0x0502)
selection
STOP
Code (Addr.)
Name
F05.03
Terminal X4 function
(0x0503)
selection
STOP
Multi-function input setting value
Set the function assigned to F05.00~F05.03.
0: no function
Indicates that the terminal is invalid. If the terminal function is idle, it is recommended to set it to "0" to prevent misoperation.
1: Forward running
When the running command is given by the terminal, if the parameter F05.20 [terminal control mode] is set to "0: two-wire system 1", the drive will run in
the forward direction when the terminal is valid. For other control modes, see F05.20. [Terminal control mode]; Start protection feature reference parameter
F07.03 [Start protection selection].
2: Reverse running
When the running command is given by the terminal, if F05.20 [terminal control mode] is set to "0: two-wire system 1", the drive will run in reverse when
the terminal is valid. For other control modes, see F05.20 [ Terminal control mode]; Start protection feature reference parameter F07.03 [Start protection
selection].
3: Three-wire operation control (Xi)
When the running command is given by the terminal, if F05.20 [terminal control mode] is set to "2(3): three-wire system 1 (2)", the terminal is the three-
wire operation control terminal (Xi). For details, see F05. .20[Terminal Control Mode]; At the same time, the startup protection feature is invalid. For details,
see parameter F07.03 [Startup Protection Selection].
4: Forward turn
5: Reverse jog
Positive and negative jog command input port. When this terminal is valid, the drive will jog. The terminal jog command has the highest priority. For detailed
setting of jog parameters, see F07.3x [Jog Parameter Group]; jog protection characteristics refer to parameter F07.03 [Start Protection Selection].
6: Free parking
When the terminal is valid, the drive immediately blocks the output, and the motor is in free running state.
When the free stop terminal is always active, the drive will not accept any start command and remain stopped.
When the keyboard, RS485, optional card and terminal three-wire control are running, after the free stop terminal command is released, the original
operation command will not be restored. If the drive needs to be started, the operation command must be re-entered.
7: Emergency stop
If an emergency stop command is input during the operation of the drive, the drive will decelerate to a stop with the deceleration time set by F05.27
[Terminal emergency stop deceleration time].
After entering the emergency stop command, it cannot be re-run until the drive has completely stopped. If F07.10 [Stop Mode] is set to Free Stop, the drive
will still perform emergency stop deceleration according to the emergency stop time.
When the emergency stop terminal is always active, the drive will not accept any start command and keep the stop command status. When the terminal
two-wire control is running, whether the original running command is restored after the emergency stop terminal command is released, see parameter
F07.03 [Startup protection selection].
When the keyboard, communication, optional card and terminal three-wire control are running, the original stop command is not restored after the
77
78
79
Content
V/F SVC
Set the function assigned to the multi-function input terminal X1
Content
V/F SVC
Set the function assigned to the multi-function input terminal X2
Content
V/F SVC
Set the function assigned to the multi-function input terminal X3
Content
V/F SVC
Set the function assigned to the multi-function input terminal X4
127
Reserved
Reserved
Reserved
Factory setting
(Setting range)
1
(0 ~ 95)
Factory setting
(Setting range)
2
(0 ~ 95)
Factory setting
(Setting range)
4
(0 ~ 95)
Factory setting
(Setting range)
8
(0 ~ 95)
AC10 Series Frequency Inverter Technical Manual
Parameter details

Advertisement