Parameter details
F06.76
vY3 output OFF delay
(0x064C)
time
RUN
F06.77
vY4 output OFF delay
(0x064D)
time
RUN
Note:
For details on the virtual digital output delay, refer to "Setting Value of Multi-function Output" in F06.2x.
11.9 F07 Group: Operation Control
F07.0x group: Start control
The drive can select 3 starting modes, according to the starting frequency starting mode, DC braking starting mode and speed tracking starting mode.
Output
frequency
Forward run
command
Reverse run
command
Schematic diagram of forward rotation start and forward and reverse switching process
Code
Name
(Addr.)
F07.00
(0x0700)
Start mode
STOP
0: started by the start frequency
In this mode, the output frequency changes directly from F07.02 [starting frequency] according to the acceleration time.
1: After DC braking, start again by starting frequency
In this mode, first press F07.20 [start DC braking current], F07.21 [start DC braking time] to perform DC braking, and then start according to the starting
frequency. Applicable to the field where the motor speed is required to be zero or lower at start-up, first give the motor a braking force and then start.
2: Speed tracking start
First detect the speed and direction of the motor, and then start according to the detected speed. Suitable for on-site quick start after large inertia load
shutdown.
Note:
When the starting frequency is less than F7.02 [starting frequency] at startup, the drive will not start, it will be in standby state, and the running
indicator will light.
The S/T2 model does not support the speed tracking start.
-excitation time
Code
Name
(Addr.)
F07.01
(0x0701)
Start pre-excitation time
STOP
Under the asynchronous motor vector, pre-excitation before starting can effectively improve the starting performance of the motor and reduce the starting
current and starting time.
Note:
When the default is 0.00s, the actual time of starting the pre-excitation is automatically calculated according to the motor parameters.
The S/T2 model does not support pre-excitation before starting.
F07.02: Starting frequency
AC10 Series Frequency Inverter Technical Manual
V/F SVC
Set the delay time for the vY3 terminal to switch from ON to OFF
V/F SVC
Set the delay time for the vY4 terminal to switch from ON to OFF
Start frequency
maintenance time
Pre-
excitation
time
0
Start DC braking time
ON
Content
V/F SVC
Set the startup mode of the drive
Content
V/F SVC
Establish a magnetic field before the motor starts, and set the pre-excitation
time by this parameter.
Starting
frequency
Positive reversal
dead time
ON
148
0.010
(0.000 ~ 60.000s)
0.010
(0.000 ~ 60.000s)
Zero speed torque
time
frequency threshold
OFF
OFF
Factory setting
(Setting range)
0
(0 ~ 2)
Factory setting
(Setting range)
0.00
(0.00~ 60.00s)