Veichi AC200 Series Manual
Veichi AC200 Series Manual

Veichi AC200 Series Manual

Frequency inverter

Advertisement

Quick Links

MANUAL
AC200 Series Frequency Inverter

Advertisement

Table of Contents
loading

Summary of Contents for Veichi AC200 Series

  • Page 1 MANUAL AC200 Series Frequency Inverter...
  • Page 2: Table Of Contents

    AC200 Frequency Inverter Maunal CONTENT ····························································································· 1 Chapter 1 Overview 1.1 Safety requirement and cautions ································································································ 1 1.2 Before Use ································································································································· 2 1.3 Technical criterion ····················································································································· 2 ··························································································· 5 Chapter 2 Installation ···················································· 11 Chapter 3 Keyboard layout and functions specification ·········································································...
  • Page 3: Chapter 1 Overview

    ● Only Veichi Electric co., ltd service department or its authorized service center can maintain the products. It may cause product fault while using accessories not authorized or permitted.Any defective components must be changed...
  • Page 4: Before Use

    AC200 Frequency Inverter Maunal 1.2 Before Use On receiving your order, please check the package and confirm intact before opening, and check if there’s any damage, scratch or dirt (damages caused during transportation are not within the company's warranty). If there’s any damage caused during transportation, please contact us or the transport company immediately.After confirming the receipt of the goods intact, please re-confirm if the product and your order are consistent.
  • Page 5 AC200 Frequency Inverter Maunal Output frequency range G type:0Hz-600Hz Output frequency accuracy Max frequency ±0.5% G type:150% rated current/1 min, 180% rated current/10s, 200% rated Overload capacity current/0.5s Motor control mode V/F without PG ,VC without PG, V/F with PG,VC with PG Modulate mode Optimized SVPWM mode Carrier frequency...
  • Page 6 AC200 Frequency Inverter Maunal Keyboard digital set, keyboard potentiometer, analog voltage terminal VS, analog voltage/current terminal AI,analog current terminal AS, Frequency set channels communication given and multi channels terminal selection, master-slave channels combination,expansion card, switch by various modes Voltage terminal VS, voltage/current terminal AI ,current terminal AS, Feedback input channel communication given, pulse input PUL.
  • Page 7: Chapter 2 Installation

    AC200 Frequency Inverter Maunal Chapter 2 Installation This section specifies the considerations necessary for reliable and safe operation of the product by users. Overall Dimension of Inverter and Keyboard INSTALLATION MODEL APERTURE AC200-S2-R40G AC200-S2-R75G 154.5 ф5 AC200-S2-1R5G AC200-S2-2R2G 147.2 157.5 ф5.5 AC200-T3-R75G AC200-T3-1R5G...
  • Page 8 AC200 Frequency Inverter Maunal Overall Dimension Instillation Position INSTALLATION MODEL APERTURE AC200-T3-030G Ф7 AC200-T3-037G AC200-T3-045G Ф9 AC200-T3-055G AC200-T3-075G AC200-T3-090G ф11 AC200-T3-110G Overall Dimension Instillation Position INSTALLATION MODEL APERTURE AC200-T3-132G ф11...
  • Page 9 AC200 Frequency Inverter Maunal AC200-T3-160G AC200-T3-185G 1060 1023 ф16 AC200-T3-200G AC200-T3-220G AC200-T3-250G 1170 1050 1128 ф18 AC200-T3-280G AC200-T3-315G AC200-T3-355G 1280 1150 1236 ф20 AC200-T3-400G Overall Dimension Instillation Position INSTALLATION MODEL APERTURE AC200-T3-160GD AC200-T3-185GD 1600 1500 ф14 AC200-T3-200GD AC200-T3-220GD AC200-T3-250GD 1700 1600 ф14 AC200-T3-280GD...
  • Page 10 AC200 Frequency Inverter Maunal Overall Dimension Instillation Position INSTALLATION MODEL APERTURE AC200-T3-450G AC200-T3-500G 1200 1850 1750 ф14 AC200-T3-560G Overall Dimension Instillation Position INSTALLATION MODEL APERTURE AC200-T3-630G ф14 1900 1800 AC200-T3-710G...
  • Page 11 AC200 Frequency Inverter Maunal Standard Connection Diagram ● Standard Connection Diagram brake module DC reactor brake resistor notice 1 short circuit circuit breaker connector input reactor output reactor ( ) + + ( ) + ( ) AC input shielded cables inverter (near inverter groud ) notice 2...
  • Page 12 AC200 Frequency Inverter Maunal ● Auxiliary Terminal Output Capacity Terminal Function Definition Max Output 10V auxiliary power supply output, constitutes +10V 50mA loop with GND. Analog monitor output, constitutes loop with Max output 2mA as frequency, A01/A02 GND. voltage signal, 24V auxiliary power supply output, constitutes +24V 100mA...
  • Page 13: Chapter 3 Keyboard Layout And Functions Specification

    AC200 Frequency Inverter Maunal Chapter 3 Keyboard layout and functions specification ● Keyboard appearance ● Key function Name Function Enter menu while standby or running. Press this key to return while Menu key modify parameter. While standby or running, press for 1 sec to enter condition monitoring interface.
  • Page 14 AC200 Frequency Inverter Maunal Name State Meaning Spark/On Frequency unit Current unit Spark/On Voltage unit Unit indicator light Time unit Motor speed unit Spark/On Percent unit Forward running State Spark Reverse running indicator light Stop REV/JOG Jog. Function indicator light REV/JOG Reverse.
  • Page 15: Chapter 4 Function Parameter Table

    AC200 Frequency Inverter Maunal Chapter 4 Function Parameter Table This chapter just provides function parameter table.Specifications refer to AC200 technical manual or inquiry the company. “●”: Parameter can be changed in the running state. “〇”: Parameter can’t be changed in the running state. “×”: Parameter can be read only.
  • Page 16 AC200 Frequency Inverter Maunal 0: Channel A 1: Channel B 2: Channel A+Channel B Frequency given source 3: Channel A-Channel B ● F0.06 0x006 selection 4: Max. value of Channel A and Channel B 5: Min. value of Channel A and Channel B LED“0”digit: keyboard command instruction binding...
  • Page 17 AC200 Frequency Inverter Maunal ※ Model set F0.14 ACC time 1 0.01s~650.00s 0x00E ※ Model set F0.15 DEC time 1 0.01s~650.00s 0x00F LED“0”digit: running direction takes the opposite 0: Direction unchanged 1: Direction takes the opposite LED“00”digit: running direction prohibited 0:Forward and reverse commands are 〇...
  • Page 18 AC200 Frequency Inverter Maunal 0: DEC stop ● Stop mode F1.10 0x10A 1: Free stop DC braking initial 〇 F1.11 0.00Hz~50.00Hz 1.00Hz 0x10B frequency when stop DC braking current when F1.12 0.0%~150.0% 60.0% 0x10C stop F1.13 Reserved 0x10D DC braking holding time 〇...
  • Page 19 AC200 Frequency Inverter Maunal Power off restart waiting 〇 F1.36 0.00s~60.00s 0.50s 0x124 time F1.37 Reserved 0x125 JOG running frequency ● 0.00Hz-Max frequency F1.38 5.00Hz 0x126 setting ● JOG ACC time F1.39 0.01s~650.00s 10.00s 0x127 ● JOG DEC time F1.40 0.01s~650.00s 10.00s 0x128...
  • Page 20 AC200 Frequency Inverter Maunal ● F2.14 0.000s~6.000s X3 valid detection delay 0.010s 0x20E ● F2.15 0.000s~6.000s X3 invalid detection delay 0.010s 0x20F ● F2.16 0.000s~6.000s X4 valid detection delay 0.010s 0x210 ● F2.17 0.000s~6.000s X4 invalid detection delay 0.010s 0x211 ●...
  • Page 21 AC200 Frequency Inverter Maunal ● F2.39 Timer time unit 0: Second1: Minute 2: Hour 0x227 ● F2.40 Timer setting value 0~65000 0x228 ● F2.41 Counter max value 0~65000 1000 0x229 ● F2.42 Counter setting value 0~65000 0x22A F2.43 Reserved 0x22B 0: Positive 1: Negative LED “0”...
  • Page 22 AC200 Frequency Inverter Maunal AI (VS)upper limit ● 0.00%~100.00% 100.00% 0x309 F3.09 corresponding setting 0.00s~6.00s F3.10 AI filter time ● 0.010s 0x30A 0.00mA~20.00mA F3.11 AS lower limit ● 4.00mA 0x30B AS lower limit ● 0.00%~100.00% 0.00% 0x30C F3.12 corresponding setting 0.00mA~20.00mA F3.13 AS upper limit...
  • Page 23 AC200 Frequency Inverter Maunal Curve 1 lower limit ● F3.33 0.0% 0x321 0.00%~100.00% corresponding setting Curve 1 inflection point 1 ● F3.34 3.00V 0x322 0.00V~10.00V input voltage Curve 1 inflection point1 ● F3.35 30.00% 0x323 0.00%~100.00% corresponding setting Curve 1 inflection point 2 ●...
  • Page 24 AC200 Frequency Inverter Maunal 0: Given frequency 1: Output frequency 2: Output current 3: Input voltage 4: Output voltage ● F3.54 0x336 A01 output selection 5: Machine speed 6: Given torque 7: Output torque 8: PID given value 9: PID feedback value 10: Output power 11: Bus voltage 12: VS input value...
  • Page 25 AC200 Frequency Inverter Maunal System Parameter Group Factory Function description Range of settings and definition Feature Address setting 0: Not locked 1: Function parameter locked Parameter and key lock 2: Function parameter and key locked ● F4.00 0x400 selections (except for RUN/STOP/JOG) 3: All function parameter and key locked User password...
  • Page 26 AC200 Frequency Inverter Maunal 1: Save frequency after power down LED “000” digit: action limit 0:Adjusting in operation& stop 1: Adjusting only in operation, stop for holding 2: Adjusting in operation, stop for clearing LED “0000” digit: reserved Keyboard potentiometer ●...
  • Page 27 AC200 Frequency Inverter Maunal LED “0” digit: C-00~C-39 0: Normal 1: Debug Reserved (debug monitor LED“00” digit: C-40~69 ● 0x417 F4.23 0000 selection) 0: No display 1: Normal LED“000”digit: reserved LED“0000” digit: reserved Rotate speed display ● 0x418 F4.24 0.0%~500.0% 100.0% coefficient ●...
  • Page 28 AC200 Frequency Inverter Maunal F4.34-F4.37 Reserved 0x422 Motor Parameter Group Factory Function description Range of settings and definition Feature Address default 0: Asynchronous motors (AM) F5.00 × 0x500 Motor mode 1: Permanent magnet synchronous motors (PM) Number of motor poles 2~98 〇...
  • Page 29 AC200 Frequency Inverter Maunal 0: OFF 1: ON 2: ON, only operate firstly when electrify F5.22-F5.29 Reserved 0x516 LED “0” digit: encoder mode 0: Common ABZ encoder 1: Rotary encoder LED “00” digit: encoder direction 0: same direction 1: reverse direction Speed feedback or LED “000”...
  • Page 30 AC200 Frequency Inverter Maunal Current loop D-axis ● 0x60A F6.10 1.000 0.001~4.000 proportional gain Current loop D-axis ● 0x60B F6.11 1.000 0.001~4.000 integral gain Current loop Q-axis ● 0x60C F6.12 1.000 0.001~4.000 proportional gain Current loop Q-axis ● 0x60D F6.13 1.000 0.001~4.000 integral gain...
  • Page 31 AC200 Frequency Inverter Maunal Frequency of current ● F6.37 10.0% 0.0%~100.0% 0x625 pulled in F6.38 F6.69 Reserved Torque Control Parameter Factory Function description Range of settings and definition Feature Address default 0:Speed control ● F7.00 Torque/Speed control 0x700 1:Torque control 0: keyboard number given 1: Keyboard potentiometer setting 2: Analog VS...
  • Page 32 AC200 Frequency Inverter Maunal 0: function code F7.13 setting 1: Keyboard potentiometer setting×F7.13 2: Analog VS×F7.13 Torque control REV speed ● F7.11 3: Analog AI×F7.13 0x70B limit selection 4: Analog AS×F7.13 5: Pulse PUL×F7.13 6: RS485 communication given×F7.13 7: Optional card×F7.13 Torque control FWD max ●...
  • Page 33 AC200 Frequency Inverter Maunal 0: Off 〇 F8.19 0x813 Auto energy saving control 1: On Energy saving frequency 〇 F8.20 15.00Hz 0x814 0.0Hz~50.00Hz lower limit Energy saving voltage 〇 F8.21 50.0% 0x815 20.0%~100.0% lower limit Energy saving voltage ● F8.22 0x816 0.010 V/ms 0.000V/ms~0.200V/ms...
  • Page 34 AC200 Frequency Inverter Maunal LED “00” digit: OC protection interference suppression 0: Off 1: First grade interference suppression 2: Second grade interference suppression LED “000” digit: SC protection First grade interference suppression 0: Off 1: First grade interference suppression 2: Second grade interference suppression LED “0000”...
  • Page 35 AC200 Frequency Inverter Maunal LED “0” digit: Output loss phase protection 0: Off 1: On LED “00” digit: Input loss phase 〇 FA.15 0011 0xA0F Loss phase protection protection 0: Off 1: Open the alarm 2: Open the fault LED “000” digit: Reserved LED “0000”...
  • Page 36 AC200 Frequency Inverter Maunal Load pre alarm detection 〇 FA.18 130.0% 0xA12 0.0%~200.0% level 1 Load pre alarm detection 〇 FA.19 5.0s 0xA13 0.0s~60.0s time 1 Load pre alarm detection 〇 FA.20 30.0% 0xA14 0.0%~200.0% level 2 Load pre alarm detection 〇...
  • Page 37 AC200 Frequency Inverter Maunal Malfunction running FA.41 × 0xA29 0.00Hz~Max frequency frequency FA.42 × 0xA2A Malfunction output voltage 0V~1500V FA.43 × 0xA2B Malfunction output current 0.1A~2000.0A Malfunction bus voltage 0V~3000V FA.44 × 0xA2C Malfunction module FA.45 × 0xA2D 0℃~100℃ temperature LED “0”...
  • Page 38 AC200 Frequency Inverter Maunal The last malfunction input FA.56 × 0xA38 See input terminal chart terminal state The last malfunction FA.57 × 0xA39 See output terminal chart output terminal state The first two malfunction FA.58 × 0xA3A Please see malfunction code table types The first three malfunction FA.59...
  • Page 39 AC200 Frequency Inverter Maunal LED “0”digit: Feedback feature selection 0: Positive feature 1: Negative feature LED “00”digit: Reserved ● Fb.07 0100 0xB07 PID control selection LED “000”digit: Reserved LED “0000”digit: Differential adjustment properties 0 : Differential of deviation 1 : Differential of feedback PID preset output 0.0%~100.0% ●...
  • Page 40 AC200 Frequency Inverter Maunal Wire break alarm lower ● Fb.28 0.0% 0xB1C 0.0%~100.0% limit Closed-loop suspend ● Fb.29 0.0% 0xB1D 0.0%~100.0% detection threshold Closed-loop suspend ● Fb.30 1.0s 0xB1E 0.0s~600.0s detection time Reserved Fb.31 0xB1F Multi-Speed and PLC Function Parameter Group Factory Function description Range of settings and definition...
  • Page 41 AC200 Frequency Inverter Maunal PLC 2nd Step running ● FC.17 10.0 0xC11 0.0(s/m/h)~6500.0(s/m/h) time PLC 3rd Step running 0.0(s/m/h)~6500.0(s/m/h) ● FC.18 10.0 0xC12 PLC 4th Step running 0.0(s/m/h)~6500.0(s/m/h) ● FC.19 10.0 0xC13 PLC 5th Step running 0.0(s/m/h)~6500.0(s/m/h) ● FC.20 10.0 0xC14 PLC 6th Step running 0.0(s/m/h)~6500.0(s/m/h)
  • Page 42 AC200 Frequency Inverter Maunal Swing frequency ● FC.52 0.0%~100.0% 0xC34 10.0% amplitude 0.0%~50.0% Jump frequency amplitude 10.0% ● FC.53 0xC35 Swing frequency rising ● FC.54 0.00s~650.00s 0xC36 5.00s time Swing frequency falling ● FC.55 0.00s~650.00s 0xC37 5.00s time Reserved FC.56 0xC38 Communication Control Function Parameter Group Factory...
  • Page 43 AC200 Frequency Inverter Maunal 0: No checkout overtime fault Modbus communication 1: Alarm and stop freely ● Fd.07 0xD07 fault action mode 2: Alarm and continue running selection 3: Forced stop Modbus transmission 0: Write operation with response ● Fd.08 0xD08 response dispose 1: Write operation without response...
  • Page 44: Terminal Input And Output Function Selection

    AC200 Frequency Inverter Maunal 4.2 Terminal Input and Output Function Selection Function Specification Function Specification Function Specification No function 16-19 Multispeed terminal 1-4 Timer clear terminal PID control cancel Counter clock input terminal PID control pause Counter clear terminal 3-line running(Xi) PID trait switch DC braking command Pre excitation command...
  • Page 45: Monitor Code

    AC200 Frequency Inverter Maunal 4.3 Monitor Code Access ‘C’ parameter group by pressing ‘PRG’ for more than 2s; check the current state of inverter. Function Code Function name Range of settings and definition Address C-00 0.01Hz 2100H Given frequency C-01 0.01Hz 2101H Output frequency...
  • Page 46: Fault Code

    AC200 Frequency Inverter Maunal Total power consumption (high C-38 10000° 2126H position) C-39 Power factor angle 1° 2127H 4.4 Fault Code Display Code Fault type Display Code Fault type Display Code Fault type System ACC over DEC over abnormal current current Overcurrent ACC over...
  • Page 47: Chapter 5 Periodic Overhaul And Maintenance

    AC200 Frequency Inverter Maunal Chapter 5 Periodic Overhaul and Maintenance 5.1 Overhaul Frequency inverter is composed by semi-conductive components, passive electronic component and motive component. All of these components have useful life. Even under normal working environment, some of the components can not work after the life time.
  • Page 48: Maintenance

    AC200 Frequency Inverter Maunal ● Peripheral equipment outlook and Peripheral equipment ● Clear and change damaged component. insulation checking. ● Fasten connector ● Peculiar smell color change, bad rust ● Clear PCB and connector checking. ● Change damaged PCB ● Check whether the fan is damaged or blocked up.
  • Page 49: Appendix : Modbus Communication Protocol

    AC200 Frequency Inverter Maunal Appendix : Modbus Communication Protocol ● Communication Frame Structure Communication data format is as follows: The byte composition: Including initiation bit, 8 data bit, check bit and stop bit. Initiation Check Stop Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7...
  • Page 50 AC200 Frequency Inverter Maunal The REV Max 0x3007 or Frequency limit in 0~1000 is corresponding to 0.0%~100.0% 0x2007 Torque Control Communication Given 0x3008 or 0~1000 is corresponding to 0.0%~100.0% PID Setting 0x2008 Communication Given 0x3009 or 0~1000 is corresponding to 0.0%~100.0% PID Feedback 0x2009 Voltage Frequency...

Table of Contents