Veichi AC10 Series Technical Manual page 107

Advertisement

Parameter copy exception
A.CoP
alarm
Note:
Parameter copying is the uploading and downloading of all parameter groups, including motor parameters, and parameters that cannot be restored
to factory values.
F00.06: LCD keyboard language selection
Code
Name
(Addr.)
F00.06
LCD keyboard language
(0x0006)
selection
RUN
Note: When the drive is initialized by F00.03 [Initialization], the parameter setting value does not change.
0: Chinese
1: English
F00.07~F00.08: Free parameter
Code
Name
(Addr.)
F00.07
(0x0007)
Free parameter 1
RUN
F00.08
(0x0008)
Free parameter 2
RUN
Note: Free parameters will not affect the operation of the drive.
E.g:
When using multiple machines, it is used as the machine number.
When using multiple machines, the mode number is used for each purpose.
Purchase, inspection, etc.
F00.1x group: common parameter settings
F00.10~F00.39: Common parameters 1~30
Code
Name
(Addr.)
F00.10~F0
0.29
Common
parameters
(0x000A~0x
1~20
01D)
RUN
F00.30~F0
0.39
Common
parameters
(0x001E~0x
21~30
027)
RUN
Note:
F00.03 = 11 or 22, F00.30~F00.39 is initialized to different values with F00.01 [use selection] during initialization.
Quickly access common parameters by setting F00.00=1[parameter access level=common parameters].
11.3 F01 Group: Basic Settings
F01.0x group: basic instructions
The F01.0x group parameters are used to set the control mode, the running command source, and the frequency reference source.
Control method
F01.00: Control mode
Code
Name
(Addr.)
F01.00
(0x0100)
control method
STOP
The control method is selected according to the type and purpose of the motor used.
0: Asynchronous motor V/F control (V/F)
This control mode is used for all variable speed control that does not require fast response and precise speed control, as well as the use of multiple
Communication exception during copying
Content
V/F SVC
Select the display language on the LCD keyboard
Content
V/F SVC
Select the language displayed on the LCD operator.
V/F SVC
When using multiple machines, it is used as the machine number.
Content
V/F SVC
20 common parameters can be registered in F00.10~F00.29, and the
registered parameters can be quickly accessed by setting F00.00
[parameter access level].
V/F SVC
10 common parameters can be registered in F00.30~F00.39, and the
registered parameters can be quickly accessed by setting F00.00
[parameter access level].
Content
V/F SVC
Select the control method according to the type and purpose of the motor
used
103
Please check or replace the keyboard cable
Factory setting
(Setting range)
0
(0 ~ 1)
Factory setting
(Setting range)
0
(0 ~ 65535)
0
(0 ~ 65535)
Factory setting
(Setting range)
General default parameters
(0000 ~ 2999)
depending on F00.01
(0000 ~ 2999)
Factory setting
(Setting range)
0
(0 ~ 1)
AC10 Series Frequency Inverter Technical Manual
Parameter details