Parameter details
Code
Name
(Addr.)
F02.08
(0x0208)
Self-learning flag
STOP
F02.1x group: asynchronous motor advanced parameters
Code (Addr.)
Name
F02.10
Asynchronous motor
(0x020A)
no-load current
STOP
Code (Addr.)
Name
F02.11
Asynchronous motor
(0x020B)
stator resistance
STOP
Note: The decimal point is set by F02.19 digits.
F02.12: Asynchronous motor rotor resistance
Code (Addr.)
Name
F02.12
Asynchronous motor
(0x020C)
rotor resistance
STOP
Note: The decimal point is set by the ten digits of F02.19.
Code (Addr.)
Name
F02.13
Asynchronous motor
(0x020D)
stator
STOP
inductance
Note: The decimal point is set by F02.19 hundred.
Code (Addr.)
Name
F02.14
Asynchronous motor
(0x020E)
stator inductance
STOP
Note: The decimal point is set by F02.19 thousand.
Code (Addr.)
Name
F02.15
Stator
resistance
(0x020F)
standard value
READ
Code
Name
(Addr.)
F02.16
Rotor
resistance
(0x0210)
standard value
READ
Code
Name
(Addr.)
F02.17
Stator
(0x0211)
inductance
READ
AC10 Series Frequency Inverter Technical Manual
Content
V/F SVC
-load current
Content
V/F SVC
Set the no-load current of the asynchronous motor
Content
V/F SVC
Set the asynchronous motor stator resistance
Content
V/F SVC
Set the asynchronous motor rotor resistance
Content
V/F SVC
leakage
Set the stator leakage inductance of the asynchronous motor
Content
V/F SVC
Set the stator inductance of the asynchronous motor
Content
V/F SVC
Set the stator resistance value. This parameter is read only
lue
Content
V/F SVC
Set the rotor resistance value. This parameter is read only
ductance value
Content
leakage
V/F SVC
Set the stator leakage inductance value. This parameter is read only
114
Factory setting
(Setting range)
0
(0 ~ 3)
Factory setting
(Setting range)
Change with model
(0.1 ~ 3000.0A)
Factory setting
(Setting range)
Change
with
model
(0.01mΩ ~ 60000mΩ)
Factory setting
(Setting range)
Change
with
model
(0.01mΩ ~ 60000mΩ)
Factory setting
(Setting range)
Change
with
model
(0.001mH ~ 6553.5mH)
Factory setting
(Setting range)
Change
with
model
(0.01mH ~ 65535mH)
Factory setting
(Setting range)
Actual value conversion
(0.00 ~ 50.00%)
Factory setting
(Setting range)
Actual value conversion
(0.00 ~ 50.00%)
Factory setting
(Setting range)
Actual value conversion
(0.00 ~ 50.00%)