Veichi AC10 Series Technical Manual page 72

Advertisement

Function Table
F03.36
(0x0324)
Overexcitation braking limit
RUN
F03.37
(0x0325)
Energy efficient operation
RUN
F03.38
Energy-saving operation excitation
(0x0326)
lower limit
RUN
F03.39
Energy-saving
(0x0327)
coefficient
RUN
F03.4x-F03.5x group: Torque Control
Parameter
(address)
Name
djustable
attribute
F03.40
(0x0328)
Torque control selection
RUN
F03.41
(0x0329)
Torque command given
RUN
F03.42
(0x032A)
Torque keyboard digital setting
RUN
F03.43
(0x032B)
Torque input lower limit
RUN
F03.44
(0x032C)
Lower limit corresponding setting
RUN
F03.45
(0x032D)
Torque input upper limit
RUN
F03.46
(0x032E)
Upper limit corresponding setting
RUN
F03.47
(0x032F)
Torque filtering time
RUN
F03.52
(0x0334)
Torque command upper limit
RUN
F03.53
(0x0335)
Torque command lower limit
RUN
F03.54
Torque control forward speed limit
(0x0336)
selection
RUN
F03.55
Torque control reverse speed limit
AC10 Series Frequency Inverter Technical Manual
SVC
Set the overexcitation brake limiter.
SVC
0: off
1: on
SVC
Set the lower limit of excitation for energy saving operation.
operating
filter
SVC
Set the energy saving operation filter coefficient.
Content
SVC
0: Speed control mode limit torque
1: Torque control mode speed limit
SVC
LED "0" digit: Channel A:
0: Torque keyboard digital reference
1: Integrated keyboard potentiometer given
2: AI
3: Reserved
4: Reserved
5: PUL
6: RS485 communication given
LED "00" digit: Channel B:
Same channel A
LED "000" digit: Combination method:
0: A
1: B
2: A+B
3: A-B
SVC
4: MIN(A,B)
Set the torque keyboard number.
5: MAX (A, B)
SVC
Set the torque input lower limit.
SVC
Set the lower limit corresponding value.
SVC
Set the upper limit of the torque input.
SVC
Set the upper limit to correspond.
SVC
Set the torque limit action frequency range at low speed.
SVC
Set the upper limit of the output torque.
SVC
Set the lower limit of the output torque.
SVC
0: Function code F03.56 is set;
1: Integrated keyboard potentiometer given × F03.56;
2: AI × F03.56;
3: Reserved;
4: Reserved
5: PUL × F03.56;
6: RS485 communication given × F03.56
7: Reserved
SVC
68
10.0%
(0.0 ~ 250.0%)
0
(0 ~ 1)
50.0%
(0.0 ~ 80.0%)
0.010s
(0.000 ~ 6.000s)
Factory default
(setting range)
0
(0 ~ 1)
0000
(0000 ~ 0566)
0.0%
(0.0 ~ 100.0%)
0.00%
(0.0 ~ 100.00%)
0.0%
(-200.0~200.0%)
100.0%
(0.0~100.0%)
100.0%
(-200.0~200.0%)
0.100s
(0.000~6.000s)
150.0%
(0.0 ~ 200.0%)
0.0%
(0.0 ~ 200.0%)
0
(0 ~ 7)
0