Veichi AC10 Series Technical Manual page 103

Advertisement

0x2009 /0x3009
PID feedback
Voltage-frequency
0x200A/0x300A
separation voltage value
setting
0x200E
Acceleration time 1
/0x300E
0x200F
Deceleration time 1
/0x300F
Fault warning,
0x2010 /0x3010
number
Torque
0x2011 /0x3011
component
0x2012 /0x3012
Torque filtering time
0x2018 /0x3018
Terminal output control
0x2019 /0x3019
AO output
0x201B/0x301B
Custom 1
0x201C
Custom 2
/0x301C
0x201D
Custom 3
/0x301D
0x201E
Custom 4
/0x301E
0x201F
Custom 5
/0x301F
Input and output interface communication group (address 0x34xx)
Address
Name
Extended
0x3400
communication mode
0x3401
Input terminal status
0x3402
Output terminal status
0x3403
Reserved
0x3404
Reserved
Multi-function
0x3405
terminal function group 0
Multi-function
0x3406
terminal function group 1
Multi-function
0x3407
terminal function group 2
Multi-function
0x3408
terminal function group 3
0.0%
R/W
(0.0~100.0%)
0.0%
R/W
(0.0~100.0%)
0.00s
R/W
(0.00~600.00s)
0.00s
R/W
(0.00~600.00s)
alarm
0
R
(0~65535)
0.0%
current
R
(0.0~400.0%)
0.000s
R/W
(0.000~6.000s)
W
Binary
0.01
W
(0~100.00)
0
R/W
(0~65535)
0
R/W
(0~65535)
0
R/W
(0~65535)
0
R/W
(0~65535)
0
R/W
(0~65535)
Read/Wr
dimension
ite
(range)
port
SPI
0
R
(0~65535)
R
Binary
R
Binary
R
--
R/W
--
input
R
Binary
input
R
Binary
input
R
Binary
input
R
Binary
Communication given PID feedback amount
Frequency conversion power supply application parameters
Read and write the value of F01.22
Read and write the value of F01.23
1~127 is the fault code, 128-159 is the warning code, and 0 is
the faultless code.
Belt special machine application parameters
Read and write the value of F03.47
Read and write the value output terminal function of F03.47,
select F6.20~F24 to select 30 [communication control output]
Bit0: Y terminal
Bit1: Relay
Bit2: Extend Y1
Bit3: Extended Relay
F06.01=18[AO function output selection=communication output]
Use with the host computer
Use with the host computer
Use with the host computer
Use with the host computer
Use with the host computer
Description
AC10 series machine defaults to 1
Bit0: X1 terminal 0-OFF 1-ON
Bit1: X2 terminal 0-OFF 1-ON
Bit2: X3 terminal 0-OFF 1-ON
Bit3: X4 terminal 0-OFF 1-ON
Bit4: X5 terminal 0-OFF 1-ON
Bit5: X6 terminal 0-OFF 1-ON
Bit6: X7 terminal 0-OFF 1-ON
Bit7: X8 terminal 0-OFF 1-ON
Bit8: X9 terminal 0-OFF 1-ON
Bit9: X10 terminal 0-OFF 1-ON
Bit0: Y terminal status 0-OFF 1-ON
Bit1: Relay status 0-OFF 1-ON
Bit2: Extended Y1 status 0-OFF 1-ON
Bit3: Extended relay status 0-OFF 1-ON
--
--
Multi-function 0~15 corresponds to one function for each
function
0-OFF
Multi-function 16~31 corresponds to one function per function
0-OFF
Multi-function 32~47 each function corresponds to one bit
0-OFF
Multi-function 48~63 each function corresponds to one bit
0-OFF
99
1-ON
1-ON
1-ON
1-ON
AC10 Series Frequency Inverter Technical Manual
Function Table