Veichi AC10 Series Technical Manual page 71

Advertisement

RUN
F03.1x group: Current loop and torque limit
Parameter
(address)
Name
djustable
attribute
F03.10
(0x030A)
Current loop D-axis proportional gain
RUN
F03.11
(0x030B)
Current loop D-axis integral gain
RUN
F03.12
(0x030C)
Current loop Q-axis proportional gain
RUN
F03.13
(0x030D)
Current loop Q-axis integral gain
RUN
F03.15
(0x030E)
Electric state torque limit
RUN
F03.16
(0x030F)
Power generation torque limit
RUN
F03.17
(0x0312)
Regenerative torque limit at low speed
RUN
F03.18
Torque
limit
(0x0313)
amplitude at low speed
RUN
F03.2x group: Torque optimization control
Parameter
(address)
Name
djustable
attribute
F03.23
Asynchronous
(0x0314)
compensation
RUN
F03.24
(0x0315)
Starting torque initial value
RUN
F03.3x group: Flux optimization
Parameter
(address)
Name
djustable
attribute
F03.30
Weak
(0x031E)
coefficient
RUN
F03.31
(0x031F)
Weak magnetic control gain
RUN
F03.32
(0x0320)
Weak magnetic current upper limit
RUN
F03.33
(0x0321)
Weak magnetic voltage coefficient
RUN
F03.34
(0x0322)
Output power limit
RUN
F03.35
(0x0323)
Overexcitation braking gain
RUN
Content
SVC
Set the current loop D-axis proportional gain.
SVC
Set the current loop D-axis integral gain.
SVC
Set the current loop Q-axis proportional gain.
SVC
Set the current loop Q-axis integral gain.
SVC
Set the motor state torque limit.
SVC
Set the generator state torque limit.
SVC
Set the regenerative torque limit value at low speed.
action
frequency
SVC
Set the torque limit action frequency range at low speed.
Content
motor
slip
SVC
Set the asynchronous motor slip compensation.
SVC
Set the initial value of the starting torque.
Content
magnetic
feedforward
SVC
Set the weak magnetic feed forward coefficient.
SVC
Set the field weakening control gain.
SVC
Set the upper limit of the field weakening current.
SVC
Set the weak magnetic voltage coefficient.
SVC
Set the output power limit.
SVC
Set the overexcitation braking gain.
67
Factory default
(setting range)
1.00
(0.001 ~ 4.000)
1.00
(0.001 ~ 4.000)
1.00
(0.001 ~ 4.000)
1.00
(0.001 ~ 4.000)
180.0%
(0.0~400.0%)
180.0%
(0.0~400.0%)
50.0%
(0.0~400.0%)
6.00s
(0.00~30.00s)
Factory default
(setting range)
100.0%
(0.0 ~ 250.0%)
0.0%
(0.0 ~ 250.0%)
Factory
(setting range)
10.0%
(0.0 ~ 200.0%)
10.0%
(0.0 ~ 500.0%)
60.0%
(0.0 ~ 250.0%)
97.0%
(0.0 ~ 120.0%)
250.0%
(0.0 ~ 400.0%)
100.0%
(0.0 ~ 500.0%)
AC10 Series Frequency Inverter Technical Manual
Function Table
default

Advertisement

loading

This manual is also suitable for:

Sis series