Download Print this page

Veichi AC10 Series Technical Manual page 109

Advertisement

Frequency command given schematic
Table 11.1 Frequency Input Selection Mode
Frequency input mode
Given source A
Given
source
Given source B
mode
Given source A, B
combination
Run command bundled given frequency mode
Multi-speed mode
Jog mode
Note:
1. The higher the priority value, the higher the priority.
2. The multi-speed mode priority is not listed in the table above when there is no multi-speed selection in the given source mode.
3. When there is a multi-speed selection in a given source mode, the multi-speed selection mode has the same priority as the other modes in the given
source.
The frequency given source A, B and the running command are bundled in the given frequency mode:
Frequency reference source input
method
Keyboard number setting
Keyboard potentiometer given
AI setting
Terminal pulse PUL
RS485 communication
Terminal up and down button control
PID control
Program control
Multi-speed
Note:
1. The reference value of the frequency reference source B is selected by F01.06 = 0, 1 [reference value of frequency reference source B = maximum
frequency, given source B]
2. The maximum frequency is the set value of F01.10.
Multi-speed operation:
The drive has a multi-speed operation function, and multiple frequency commands can be preset as needed. The multiple frequency command values are
set in the F14.00~F14.14 parameters, and the set frequency command is selected by combining with the multi-function input signal from the outside. The
required frequency command can be selected by the ON/OFF of the contact input to change the motor speed by the gear. Up to 17 speeds can be switched
by the 16-speed frequency command and one jog frequency command (JOG command).
The combination of multiple speed commands is shown in the table below.
Table 11.1 Combination of multiple speed command and multi-function contact input terminal
Related parameters
F01.09
keyboard
digital
setting
F14.00 multi-speed 1
F14.01 multi-speed 2
F14.02 multi-speed 3
F14.03 multi-speed 4
F14.04 multi-speed 5
F14.05 multi-speed 6
F14.06 multi-speed 7
F14.07 multi-speed 8
F14.08 multi-speed 9
F14.09 multi-speed 10
F14.10 multi-speed 11
Priority
1
1
1
2
3
4
Description
F01.09 set value as a given frequency
The value of the potentiometer after linearization is 0~100% corresponding to 0~maximum frequency
AI input linearized value 0~100% corresponds to 0~maximum frequency
PUL input linearized value 0~100% corresponds to 0~maximum frequency
RS485 communication writes the value to the 0x3000 address to get the given frequency value.
Set the upper and lower key control modes and the acceleration and deceleration rate through F05.25 and
F05.26.
F13 group process PID control output value 0~100% corresponds to 0~maximum frequency
The F14 group program controls the frequency set in each segment as the given frequency.
The multi-terminal terminal is set to multi-speed selection to determine the frequency of the corresponding
segment as a given frequency.
Multi-speed
Multi-speed
terminal 1
terminal 1
F05.0x = 16
F05.0x = 16
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Description
Given source A input, related parameters F01.02, F01.03
Given source B input, related parameters F01.04, F01.05, F01.06
Given the source A, B channel combination given frequency by F01.07
Set the binding frequency of the command channel by F01.08
Multi-function terminal set to multi-speed selection to set frequency
When the jog command is valid, the jog frequency is set by F07.30.
Multi-speed
terminal 1
F05.0x = 16
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
105
Parameter details
Multi-speed
Multi-speed
terminal 1
terminal 1
F05.0x = 16
F05.0x = 4/5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
AC10 Series Frequency Inverter Technical Manual

Advertisement

loading

This manual is also suitable for:

Sis series