Function Table
F10.22
(0x0A16)
Ground short circuit protection option
STOP
F10.23
(0x0A17)
Fan ON/OFF control selection
RUN
F10.24
(0x0A18)
Fan control delay time
STOP
F10.25
(0x0A19)
Drive overheating oH1 detection level
RUN
F10.3x group: Load protection
Parameter
(address)
Name
djustable
attribute
F10.30
Motor
(0x0A1E)
coefficient
STOP
F10.31
Selection
(0x0A1F)
characteristics at low speed
STOP
F10.32
(0x0A20)
Load warning checkout setting
STOP
F10.33
(0x0A21)
Load warning detection level 1
STOP
F10.34
(0x0A22)
Load warning detection time 1
STOP
AC10 Series Frequency Inverter Technical Manual
overload
protection
curve
of
drive
overload
V/F SVC
Set whether the drive output and the drive cooling fan ground
short circuit protection function are enabled.
LED "0" digit: Output short circuit protection
0: Off 1: On
LED "00" digit: Fan to ground short circuit protection
0: Off 1: On
Set the drive cooling fan operation mode
0: The fan runs after the drive is powered on.
1: After the shutdown, the fan operation is related to temperature,
and the operation is running.
2: After the shutdown, the fan stops after F10.24, and the
operation is related to temperature.
V/F SVC
Set the time from when the run command is canceled to when
the cooling fan stops running.
V/F SVC
Set the temperature value of the drive overheat warning, which
is greater than the value to report the overheat warning.
Content
V/F SVC
Set the coefficient of overload protection for the load motor.
Increasing this value can increase the overload capacity of the
motor.
V/F SVC
When the low speed (less than 5Hz) is set, the overload
protection function of the drive is valid.
0: Invalid 1: Valid
V/F SVC
Set the drive load warning detection mode and the early warning
mode at this time
LED "0" digit: Load warning detection 1 setting
0: no detection
1: Detection load is too large
2: Excessive load detection only at constant speed
3: Insufficient detection load
4: Insufficient load detection only at constant speed
LED "00" digit: Alarm setting when the alarm is detected
0: Continue to run, report A.LD1
1: Free stop, reported to E.LD1
LED "000" digit: Load Warning Checkout 2 Settings
0: no detection
1: Detection load is too large
2: Excessive load detection only at constant speed
3: Insufficient detection load
4: Insufficient load detection only at constant speed
LED "0000" digit: Early warning set when load warning is
detected 2
0: Continue to run, report A.LD1
1: Free stop, reported to E.LD1
V/F SVC
Set the detection value of load warning 1
When VF is controlled, this value is 100% corresponding to the
rated current of the motor.
When vector control, this value corresponds to 100% of the rated
output torque of the motor.
V/F SVC
Set the duration of the detected load warning 1 and the load is
greater than the load warning detection level for the duration, and
the load warning is detected.
84
11
(00 ~12)
1
(0~2)
30.00s
(0 ~600.00)
80.0℃
(0 ~100.0)
Factory default
(setting range)
100.0%
(0 ~250.0%)
0
(0 ~1)
0000
(0000 ~1414)
130.0%
(0 ~200.0%)
5.0s
(0 ~60.0)