12.2 NORMALLY CLOSED DRY CONTACT

12.2.1 DETAILS

Terminals
Name
Type

12.2.2 INTENDED FIELD DEVICE CONNECTIONS

The PF3113-00 normally closed contact is not safety rated and cannot be used for safety critical functions.

Field Device

Site equipment status
panel
12.2.3 NORMALLY CLOSED DRY CONTACT BEHAVIOR
Mode
Condition
Disabled
Any
No controllers in the appliance are in a running state
Started Status
One or more controllers in the appliance are in a running state
No controllers in the appliance have high temperature alarms present
High Temp
Status
Any controller in the appliance has a high temperature alarm present
Any controller in the appliance has alerts present
No Alert status
No controllers in the appliance have alerts present
No controller in the appliance is in a Process Control state
Appliance
Process Control
Any controller in the appliance is in a Process Control state
Connected controller is not in a Process Control state
Controller
Process Control
Connected controller is in a Process Control state
Configured temperature input is below its corresponding setpoint *
Temp Setpoint
Trip
Configured temperature input is above its corresponding setpoint
Configured input is below its corresponding setpoint *
Input Setpoint
Trip
Configured input is above its corresponding setpoint
Connected controller is not Purging
Purge Status
Connected controller is Purging
* Input must go below its configured setpoint minus deadband to transition from Closed to Open
Copyright © 2022, Profire Energy. All rights reserved.
855.PRO.FIRE | PROFIREENERGY.COM
1 & 2
N.C. Dry Contact Out
Normally closed dry contact
Configuration Requirements
I/O Wizard > I/O Modules Tab
N.C. Dry Contact: As desired
PF3100 Product Manual
Signal Out Termination
Ground
Floating
6
7
8
9 10 11 12 13
1 2 3 4
Input #
Earth GND
6
7
8 9 10
11 12 13
5
4
N.O. Dry
Contact
3
Ou t
2
N.C. Dry
Contact
1
Ou t
4-20mA
Input 1
Input 2
Ou t
SPST 120 VAC/DC, 80mA max
PF3113-00
XX:00:00:00:XX:XX
PF3113-00
139750
Reset
IO Expansion Card
2021-12-31
V2.0
v2.0.x
Connection Diagrams
Run Status – AC
Run Status – DC
Contact State
DOC-001149 v8.0
14 15 16 17 18 19
14 15 16
17 18 19
Input 3
Input 4
12V
24V
PWR Out
Mode
20 - PFRN
CLOSED
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
71

Advertisement

Table of Contents
loading

Table of Contents