Ion Pilot Valve Output - ProFire PF3100 Product Manual

Hide thumbs Also See for PF3100:
Table of Contents

Advertisement

6.3

ION PILOT VALVE OUTPUT

6.3.1
DETAILS
Terminals
Name
Type
6.3.2
INTENDED FIELD DEVICE CONNECTIONS
Field Device
12V normally closed gas shutoff
valve – Peak and hold
12V normally closed gas shutoff
valve – Constant current
24V normally closed gas shutoff
valve
6.3.3
ION PILOT VALVE OUTPUT BEHAVIOR BY CONTROLLER STATE
Pilot Off Mode Setting
Disabled
Off at Setpoint
Follow Main
Off after Main On
1
E = Energized, D = De-energized
2
Main Flame Detect setting must be enabled
3
Energized under reignition conditions in accordance with configured Pilot Relight Mode and Pilot Relight Timeout settings
(Controller Settings > Outputs > Ignition).
Copyright © 2022, Profire Energy. All rights reserved.
855.PRO.FIRE | PROFIREENERGY.COM
3 & 4
Valve
12V Powered solenoid output with
configurable PWM
Configuration Requirements
Pilot Wizard > Allocate Pilot Tab
Enabled/Disabled: Enabled
Pilot Wizard > Ignition Settings Tab
Minimum Pilots Running: As required per appliance safety
specifications
Pilot Relight Mode: As desired
Controller Settings > Outputs > Valves
Pilot Valve PWM: As desired
Controller Settings > Process Control > Process Temp Control
Pilot Off Mode: As desired
Controller Settings > Inputs > Flame Detection
Main Flame Detect: As desired per Pilot off Mode
Same as above except:
Controller Settings > Outputs > Valves
Pilot Valve PWM: 100%
Not Supported - Connect to the BMS card
card Valve output.
D
D
D
D
D
D
D
D
PF3102-00
XX:00:00:00:XX:XX
139750
2021-12-31
v2.2.x
LEL
COIL
MAIN
PILOT
Pilot Solenoid Output
D
D
D
E
D
D
D
E
PF3100 Product Manual
DOC-001149 v8.0
CAT5/6
PF3102-00 Ion Pilot Module
v2.2
Connection
Diagrams
Solenoid Output
Solenoid Output
rather than the Ion Pilot
E
E
E
E
D
2,3
D
2,3
45