Code
Alert Name
UI/Modbus
1108
109
PID Configuration Error
1109
110
Pilot Configuration Error
Bleed Valve Closed with Main
1110
111
Off
1111
112
Bleed Valve Open with Main ON
1112
113
The Bleed Valve Input is Invalid
1113
114
BMS Wait Timeout
1114
115
IO Expansion Wait Timeout
One or more descriptors are
1115
116
Invalid
1116
117
Settings CRC Mismatch
1117
118
Airflow Input Stuck
Secondary PID Configuration
1118
119
Error
1119
120
UV Flame Detect Stale Data
IO 4-20 Output PID
1120
121
Configuration Error
IO Expansion Dry Contact
1121
122
Configuration Error
1122
123
System is in Calibration Mode
1123
124
Low %O
2
Copyright © 2022, Profire Energy. All rights reserved.
855.PRO.FIRE | PROFIREENERGY.COM
4-20 Aux Out Mode setting is set to PID, Low Fire Mode setting is enabled
and any of the following Advanced PID Config conditions exist:
1. Primary Setpoint Min > Primary Setpoint Max
2. Secondary Setpoint Min > Secondary Setpoint Max
3. Secondary Input invalid (Both a temperature input and I/O expansion
input have been configured as Secondary PID inputs).
4. Staging Input Invalid (Input type selected in the I/O Expansion Wizard is
not suitable for PID staging).
The number of connected and enabled Pilot cards is lower than the
configured Minimum Pilots Running setting.
The bleed valve proof of open contact is open, indicating the bleed valve is
closed (no flow) during main off.
The bleed valve proof of open contact is closed, indicating that the bleed
valve is open (flow) while the main is on.
The bleed valve proof of open contact input is invalid.
A BMS wait has been present for longer than the configured BMS Wait
Timeout setting.
An IO Expansion wait has been present for longer than the configured IO
Wait Timeout setting
Internal BMS Card Fault.
Contact
Settings have been corrupted and cannot be verified
The Proof of Airflow contact is closed during the Startup Checks State.
1.
Input Mode setting (I/O Wizard > Add Inputs Tab) is configured as
"Secondary PID input" for more than one input.
2.
Secondary PID input Signal Type setting (I/O Wizard > Add Inputs Tab)
is configured as "Digital"
3.
Aux Out Mode setting (BMS Settings > Outputs > 4-20 Aux Out) is not
set to "BMS PID".
4.
Secondary PID input is not assigned as the Secondary Input (BMS
Settings > Process Control > Advanced PID Config).
Internal UV Pilot card fault.
4-20 Output setting (I/O Wizard > I/O Modules Tab) is set to PID Output
Controlled by TC Input but has no temperature input assigned.
* Pressing the OK button on the alert text opens a dialog that identifies the
offending card and input.
IO Expansion Dry Contact setting (I/O Wizard > I/O Modules Tab) is
configured as Temp Setpoint Trip or Input Setpoint Trip and Dry Contact
Trip Configuration setting (I/O Wizard > I/O Modules Tab) is unassigned or
assigned input has an invalid mode configured.
* Pressing the OK button on the alert text opens a dialog that identifies the
offending card and input.
The system is currently calibrating a 4-20 mA output.
The Oxygen Sensor input reading is less than its configured Low Setpoint
setting.
* This alarm is ignored when the controller is not actively trimming O
the controller is not in Process Control or the warmup conditions have
not been met.