5.8

AUXILIARY 4-20mA OUTPUT

5.8.1
DETAILS
Terminals
Name
Type
5.8.2
INTENDED FIELD DEVICE CONNECTIONS
Field Device/Application
4-20mA proportional fuel gas
valve using internal PID
algorithm
4-20mA proportional fuel gas
valve using external firing rate
input
4-20mA proportional fuel gas
valve using Primary and
Secondary PID control.
4-20mA proportional fuel gas
valve using cascaded Primary
and Secondary PID control.
4-20mA proportional fuel gas
valve using a PID staging input
in conjunction with Primary
and Secondary PID control.
BMS input echo to PLC
(Process temp, Pressure or
Level/Flow
Not Used
Copyright © 2022, Profire Energy. All rights reserved.
855.PRO.FIRE | PROFIREENERGY.COM
14 & 15
Aux Out
4-20mA powered output
Configuration Requirements
Controller Settings > Process Control > Process Temp
Control
Low Fire Mode: Not disabled
Controller Settings > Process Control > Cold Start
Ramping
All settings: As desired
Controller Settings > Outputs > 4-20 Aux Out
4-20 Aux Out Mode: PID Control
Manual Override: Disabled
All other settings: As desired
FARC Settings (If applicable)
Off Position: As desired
Light Off Position: As desired
Same as previous with the following exceptions:
Controller Settings > Outputs > 4-20 Aux Out
4-20 Aux Out Mode: Appliance Firing Rate
I/O Wizard > Add Inputs Tab
Input Type: Appliance Firing Rate
I/O Wizard > Create Inputs & I/O Modules Tabs
Create a Secondary PID control input
Create a PID staging input if required
Controller Settings > Outputs > 4-20 Aux Out
4-20 Aux Out Mode: PID Control
Controller Settings > Process Control > Secondary PID
All settings: As desired per PID control preferences
Controller Settings > Process Control > Advanced PID
Cascaded PID: As required
PID Staging Mode: As desired
Secondary Input: Assign secondary PID input created
above
Staging Input: Assign staging input created above if
required
All other settings: As desired
Refer to
PID Tuning Guide
document for additional
configuration details.
Controller Settings > Outputs > 4-20 Aux Out
4-20 Aux Out Mode: Desired Echo setting
Controller Settings > Outputs > 4-20 Aux Out
4-20 Aux Out Mode: Disabled
PF3100 Product Manual
DOC-001149 v8.0
PFRN Controller Network
PFRN IO Network
33 – Ignition
Switch
PF3101-00
BMS Controller
R un Ign it e O n
V1.3
35 – License Key
PF3101-00
XX: 00:00: 00:XX: XX
## ## ##
Push Tabs
YYYY-MM-DD
To Remove Key
V# .#. #
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13 12
11 10
9
8
7
6
5
4
STATUS
SPST
NO
80mA
4-20mA / Dry
4-20mA
12/24V
Power Input
120 VAC/
120 VDC
Contact Inputs
MAX
Dry Contact Inputs
Powered Outputs
Relay Output
Connection Diagrams
Proportional Valve/Actuator
Wiring
Proportional Valve/Actuator
Wiring
Proportional Valve/Actuator
Wiring
4-20mA Echo to PLC
N/A
26
10A
Fuse
3
2
1