16.3 USER INTERFACE SETTINGS

The User Interface settings (System Screen > Config Tab > Settings) apply to all appliances in the system.
4. Configure all User Interface settings as desired. The table below outlines the available configuration
options:
Setting
Date / Time
Display Sleep
Timeout
Temperature
Units
Pressure Units
Volume Units
Debug Mode
Level 1
Password
Enabled
Copyright © 2022, Profire Energy. All rights reserved.
855.PRO.FIRE | PROFIREENERGY.COM
Default
Options
Jan. 01, 1970
Any
0.5 min – 60
3.0 min
min
C
Celsius
F
kPa
PSI
inWC
cmWC
kPa
kg/cm
2
%
mA
L
m
3
Gal
Liters
BBL
%
mA
L/min
Enabled
Disabled
Disabled
Enabled
Enabled
Disabled
Description
Specifies the current date and time
Specifies the time of user inactivity after which the UI screen
turns off.
Celsius
Fahrenheit
Kilopascals
Pounds per square inch
Inches of water column
Centimeters of water column
Kilograms per square
centimeter
Percent
Milliamps
Liters
Cubic meters
US gallons
Barrels
Percent
Milliamps
Liters per minute
Appliance software diagnostic events are displayed to the user
through an on-screen pop-up menu.
Appliance software diagnostic events are hidden.
The L1 password or higher must be used to access non-safety
critical settings.
The L1 settings can be modified with no password.
PF3100 Product Manual
DOC-001149 v8.0
Specifies the display units for
all temperature card inputs.
Specifies the display units for
the BMS pressure input when
Fuel Pressure Input Mode
setting is set to 4-20.
Specifies the display units for
the BMS level/flow input
when
Level/Flow Input Mode
setting is set to 4-20.