CHAPTER 2 INSTALLATION
System Data Entry
To reset CAT mode:
While "COMMAND = -" is displayed on the LCD:
1.
Lift the handset (off hook)
-
SPKR/Speaker lamp turns off.
2.
Restore the handset (on hook)
-
CNF/Conf, FNC/Feature lamps turn off.
-
LCD returns to clock.

MAT

Refer to the MATWorX User Guide.

Cofirming Lamp Indication

After system data entry, confirm proper operation of the system using indicator lamps.
• RUN Lamp Flashing (120 IPM)
Check that the RUN lamps of PN-CP14/PN-CP20 card and other application circuit cards
are flashing.
• ON Lamps of All PZ-PW121/PZ-PW126 Cards Lighting
Check that the ON lamps of all the PZ-PW121/PZ-PW126 cards are lighting and their MJ/
MN lamps have gone out.
• BL Lamps Gone Out
Check that the BL lamps of all the line/trunk circuit cards have gone out. If BL lamps are
flashing, it means that the corresponding circuit is in make-busy state or the system data for
this card is not assigned.
For more details of lamp indication, see
information about maintenance servicing and troubleshooting of the equipment, refer to the
Maintenance Manual.
Page 220
Chapter
3,
"Lamp Indications and Switch
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Settings". For
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 3.0