SWITCH
NAME
SW2 (DIP SW)
ON
1 2 3 4 5 6 7 8
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 3.0
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
SWITCH
SETTING
NUMBER
POSITION
ON
1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
ON
5
OFF
ON
6
OFF
ON
7
OFF
ON
8
OFF
FUNCTION
Control channel signaling data
transmission speed: 48 kbps
Control channel signaling data
transmission speed: 64 kbps
DTI frame configuration: 12-Multi
Frame
DTI frame configuration: 24-Multi
Frame
Line code: AMI with ZCS
Line code: B8ZS
Setting of control signal time slot
SWITCH NUMBER
4
5
6
7
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
NOTE 4: Time slots 0, 20, 21, and
22 (TS0/20/21/22) cannot
be used for control signal.
NOTE 5: This
setting
identical with the opposite
DAIB card.
PN-DAIA-A (DAI)
CHECK
TIME SLOT
NUMBER
8
ON
TS1
ON
TS2
ON
TS3
ON
TS4
ON
TS5
ON
TS6
ON
TS7
ON
TS8
ON
TS9
ON
TS10
ON
TS11
ON
TS12
ON
TS13
ON
TS14
ON
TS15
OFF
TS16
OFF
TS17
OFF
TS18
OFF
TS19
OFF
TS23
must