NEC NEAX2000 IVS2 Installation Manual page 355

Integrated voice server
Hide thumbs Also See for NEAX2000 IVS2:
Table of Contents

Advertisement

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAID (DAI)
NOTE 3: When the clock source office signal is supplied via the line between the Main Site and
the Remote Site, set the SW1-1 and SW1-2 according to the following table. In this
case, DAID cards (DAID0, DAID1) must be mounted in PIM 0.
CONDITIONS
One DAID card is
provided.
Two or three DAID
cards are
provided.
Page 326
DAID0
DAID1
SW
SW
SW
1-1
1-2
1-1
ON
OFF
ON
OFF
OFF
DAID2
SW
SW
SW
1-2
1-1
1-2
ON
OFF
OFF
NEAX2000 IVS
REMARKS
The clock signal is sent to
PLO 0 of MP card via
Supply Route 0 (DAID0).
The clock signal supply
route is automatically
changed to Route 1
(DAID1) if a transmission
line failure occurs on
Supply Route 0.
2
Installation Procedure Manual
ND-70928 (E), Issue 3.0