NEC NEAX2000 IVS2 Installation Manual page 295

Integrated voice server
Hide thumbs Also See for NEAX2000 IVS2:
Table of Contents

Advertisement

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-B (AP00)
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
NOTE 3: When the DCE connected to the port does not provide a function to send the DSR
signals, set the switch to ON. In this case, the AP00 card cannot recognize the actual
state of the DCE, so that the call records or system messages will not be stored in the
memory buffer on the AP00 card even if the cable is disconnected from the DCE.
When the switch is set to OFF, the call records or system messages will be stored
when the cable is disconnected, and will be sent when the cable is re-connected.
NOTE 4: The use of the external clock (from the distant end) or the internal clock is determined
by the following table:
Page 266
SW2
CLOCK
2
External
ON
Internal
OFF
6
OFF
ON
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 3.0