CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIC (DAI)
SWITCH
NAME
SW3 (DIP SW)
ON
1 2 3 4
The figure in the SWITCH NAME column and the position in
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE:
When the power is on, flip MB switch to ON (UP position) before plugging/unplugging
the circuit card.
Page 320
SWITCH
SETTING
NUMBER
POSITION
ON
1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
FUNCTION
Set the equalizer according to the
cable length between the system
and the CSU.
SW
SW
SW
-1
-2
-3
0 - 40 m
ON
ON
ON
(0-131.2 ft.)
40 - 80 m
ON
ON
OFF
(131.2-262.5 ft.)
80 - 120 m
ON
OFF
ON
(262.5-394 ft.)
120 - 160 m
ON
OFF OFF
(394-525 ft.)
160 - 200 m
OFF
ON
ON
(525-656 ft.)
OFF OFF OFF Signal is not sent
When mounting this card on
Remote Site.
When mounting this card on Main
Site.
in the SETTING POSITION
NEAX2000 IVS
CHECK
CABLE
LENGTH
2
Installation Procedure Manual
ND-70928 (E), Issue 3.0