Switch Settings
SWITCH NAME
SENSE
(Rotary SW)
F
4
NOTE 1
MB (Toggle SW)
ON
NOTE 2
SW1
(Piano Key SW)
OFF
4
3
2
1
ON
JP0
(Jumper pin)
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 3.0
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
SWITCH
SETTING
NUMBER
POSITION
4-F
Set the switch to match the AP number (04-15) to
be set by CM05.
AP No.
04
05
SW No.
4
5
0-3
Not used
UP
DOWN
ON
1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
RIGHT
FUNCTION
06
07
08
09
10
6
7
8
9
A
For make-busy
For normal operation
For make-busy No. 0 circuit
For normal operation
For make-busy No. 1 circuit
For normal operation
For make-busy No. 2 circuit
For normal operation
For make-busy No. 3 circuit
For normal operation
For normal operation
PN-4RSTC (CIR)
11
12
13
14
15
B
C
D
E
F
CHECK
Page 379