Parameter Descriptions
[31] Pulse
edge
triggered
3
3
[32] Pulse time
based
[34] Ramp bit 0 Enables a choice between one of the 4 ramps
[35] Ramp bit 1 Same as Ramp bit 0.
Preset ramp bit
Ramp 1
Ramp 2
Ramp 3
Ramp 4
[36] Mains failure
inverse
[41] Latched
Precise Stop
inverse
[55] DigiPot
Increase
[56] DigiPot
Decrease
[57] DigiPot Clear
70
FC 300 Programming Guide
Edge triggered pulse input counts number of
pulse flanks per sample time. This gives a higher
resolution at high frequencies, but is not as
precise at lower frequencies. Use this pulse
principle for encoders with very low resolution
(e.g. 30 ppr).
Time based pulse input measures the duration
between flanks. This gives a higher resolution at
lower frequencies, but is not as precise at higher
frequencies. This principle has a cut-off frequency
which makes it unsuited for encoders with very
low resolutions (e.g. 30 ppr) at low speeds.
a: very low encoder
b: standard encoder
resolution
resolution
available, according to the table below.
1
0
0
1
1
Activates par. 14-10 Mains Failure. Mains
failure inverse is active in the Logic .0.
situation.
Sends a latched stop signal when the precise
stop function is activated in par. 1-83 Precise
Stop Function. The Latched Precise stop
inverse function is available for terminals 18 or
19.
INCREASE signal to the Digital Potentiometer
function described in par. group 3-9*
DECREASE signal to the Digital Potentiometer
function described in par. group 3-9*
Clears the Digital Potentiometer reference
described in par. group 3-9*
MG.33.M9.02 - VLT
[60] Counter A
[61] Counter A
[62] Reset
Counter A
[63] Counter B
[64] Counter B
[65] Reset
Counter B
[70] Mech. Brake
Feedback
[71] Mech. Brake
Feedback inv.
[72] PID error
inverse
[73] PID reset I-
part
[74] PID enable
[80] PTC Card 1
0
5-10 Terminal 18 Digital Input
0
1
Option:
Function:
0
[8]
Start Functions are described under 5-1* Digital Inputs
*
1
5-11 Terminal 19 Digital Input
Option:
Function:
[10]
Reversing Functions are described under 5-1* Digital Inputs
*
5-12 Terminal 27 Digital Input
Option:
[2]
Coast inverse Functions are described under 5-1* Digital
*
®
is a registered Danfoss trademark
(Terminal 29 or 33 only) Input for increment
counting in the SLC counter.
(Terminal 29 or 33 only) Input for decrement
counting in the SLC counter.
Input for reset of counter A.
(Terminal 29 or 33 only) Input for increment
counting in the SLC counter.
(Terminal 29 or 33 only) Input for decrement
counting in the SLC counter.
Input for reset of counter B.
Brake feedback for hoisting applications: Set
par. 1-01 Motor Control Principle to [3] flux w/
motor feedback; set par. 1-72 Start Function to
[6] Hoist mech brake Ref.
Inverted brake feedback for hoisting applica-
tions
When enabled, it inverts the resulting error
from the process PID controller. Available only
if "Configuration Mode" is set to "Surface
Winder", "Extended PID Speed OL" or
"Extended PID Speed CL".
When enabled, resets the I-part of the Process
PID controller. Equivalent to par. 7-40 Process
PID I-part Reset. Available only if "Configura-
tion Mode" is set to "Surface Winder",
"Extended PID Speed OL" or "Extended PID
Speed CL".
When enabled, enables the extended process
PID controller. Equivalent to par. 7-50 Process
PID Extended PID. Available only if "Configura-
tion Mode" is set "Extended PID Speed OL" or
"Extended PID Speed CL".
All Digital Inputs can be set to PTC Card 1 [80].
However, only one Digital Input must be set to
this choice.
Function:
Inputs

Advertisement

Table of Contents