Parameter Descriptions
13-02 Stop Event
Select the boolean (TRUE or FALSE) input to activate Smart Logic
Control.
Option:
[15] Above feedb. high
3
3
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
[22] Comparator 0
[23] Comparator 1
[24] Comparator 2
[25] Comparator 3
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[30] SL Time-out 0
[31] SL Time-out 1
[32] SL Time-out 2
[33] Digital input DI18
[34] Digital input DI19
[35] Digital input DI27
[36] Digital input DI29
[37] Digital input DI32
[38] Digital input DI33
[39] Start command
[40] Drive stopped
[41] Reset Trip
[42] Auto-reset Trip
[43] Ok key
[44] Reset key
[45] Left key
[46] Right key
[47] Up key
[48] Down key
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[61] Logic rule 5
[70] SL Time-out 3
[71] SL Time-out 4
[72] SL Time-out 5
[73] SL Time-out 6
[74] SL Time-out 7
[75] Start command given
124
FC 300 Programming Guide
Function:
SL Time-out 3 [70] Smart Logic
Controller timer 3 is timed out.
SL Time-out 4 [71] Smart Logic
Controller timer 4 is timed out.
SL Time-out 5 [72] Smart Logic
Controller timer 5 is timed out.
SL- Time-out 6 [73] Smart Logic
Controller timer 6 is timed out.
SL Time-out 7 [74] Smart Logic
Controller timer 7 is timed out.
MG.33.M9.02 - VLT
13-02 Stop Event
Select the boolean (TRUE or FALSE) input to activate Smart Logic
Control.
Option:
[76] Digital input x30/2
[77] Digital input x30/3
[78] Digital input x30/4
[79] Digital input x46/1
[80] Digital input x46/3
[81] Digital input x46/5
[82] Digital input x46/7
[83] Digital input x46/9
[84] Digital input x46/11
[85] Digital input x46/13
13-03 Reset SLC
Option:
[0]
Do not reset SLC Retains programmed settings in all group
*
[1]
Reset SLC
3.14.3 13-1* Comparators
Comparators are used for comparing continuous variables (i.e.
output frequency, output current, analog input etc.) to fixed
preset values. In addition, there are digital values that will be
compared to fixed time values. See explanation in
par. 13-10 Comparator Operand. Comparators are evaluated
once in each scan interval. Use the result (TRUE or FALSE)
directly. All parameters in this Par. group are array parameters
with index 0 to 5. Select index 0 to programme Comparator 0,
select index 1 to programme Comparator 1, and so on.
13-10 Comparator Operand
Array [6]
Option:
Choice [1] to [31] are variables which will be
compared based on their values. Choice
[50] to [186] are digital values (TRUE/FALSE)
where the comparison is based on the
amount of time during which they are set
to TRUE or FALSE, respectively. See
par. 13-11 Comparator Operator.
Select the variable to be monitored by the
comparator.
[0]
DISABLED
DISABLED [0] The comparator is disabled.
*
[1]
Reference
Reference [1] The resulting remote reference
(not local) as a percentage.
[2]
Feedback
Feedback [2] In the unit [RPM] or [Hz]
[3]
Motor speed
Motor speed [3] [RPM] or [Hz]
[4]
Motor current
Motor current [4] [A]
®
is a registered Danfoss trademark
Function:
Function:
13 parameters (13-*).
Resets all group 13 parameters (13-*) to
default settings.
Function: