Danfoss FC 300 Programming Manual page 102

Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

Parameter Descriptions
8-14 Configurable Control Word CTW
Option:
[0]
None
3
3
[1]
Profile default
*
[2]
CTW Valid, active low
3.10.3 8-3* FC Port Settings
8-30 Protocol
Option:
[0]
FC
*
[1]
FC MC
[2]
Modbus RTU
8-31 Address
Range:
Application
dependent
*
8-32 FC Port Baud Rate
Option:
[0]
2400 Baud
[1]
4800 Baud
[2]
9600 Baud
*
[3]
19200 Baud
[4]
38400 Baud
[5]
57600 Baud
[6]
76800 Baud
[7]
115200 Baud
8-33 Parity / Stop Bits
Option:
[0]
Even Parity, 1 Stop Bit
*
[1]
Odd Parity, 1 Stop Bit
[2]
No Parity, 1 Stop Bit
[3]
No Parity, 2 Stop Bits
8-34 Estimated cycle time
Range:
0 ms
[0 - 1000000
*
ms]
102
FC 300 Programming Guide
Function:
Selection of control word bit 10 if it is
active low or active high
Function:
Select the protocol for the FC (standard) port.
Function:
[Application
Enter the address for the FC
dependant]
(standard) port.
Valid range: 1 - 126.
Function:
Baud rate selection for the FC (standard) port.
Function:
Function:
In a noisy environments, the interface may
be blocked by due to overload of bad
frames. This parameter specifies the time
between two consecutive frames on the
network. If the interface does not detect
valid frames in that time it flushes the
receive buffer.
MG.33.M9.02 - VLT
8-35 Minimum Response Delay
Range:
10 ms
[Application
*
dependant]
8-36 Max Response Delay
Range:
Application
[Application
dependent
dependant]
*
8-37 Max Inter-Char Delay
Range:
Application
[Application
dependent
dependant]
*
3.10.4 8-4* FC MC protocol set
8-40 Telegram selection
Option:
[1]
Standard telegram 1 Enables use of freely configurable
*
[100] None
[101] PPO 1
[102] PPO 2
[103] PPO 3
[104] PPO 4
[105] PPO 5
[106] PPO 6
[107] PPO 7
[108] PPO 8
[200] Custom telegram 1
[202] Custom telegram 3
®
is a registered Danfoss trademark
Function:
Specify the minimum delay time
between receiving a request and
transmitting a response. This is used for
overcoming modem turnaround delays.
Function:
Specify the maximum permissible
delay time between transmitting a
request and receiving a response.
Exceeding this delay time will
cause control word time-out.
Function:
Specify the maximum permissible
time interval between receipt of two
bytes. This parameter activates time-
out if transmission is interrupted.
This parameter is active only when
par. 8-30 Protocol is set to FC MC [1]
protocol.
Function:
telegrams or standard telegrams for
the FC port.
Enables use of freely configurable
telegrams or standard telegrams for
the FC port.

Advertisement

Table of Contents
loading