Parameter Descriptions
35-25 Term. X48/7 Temp. Monitor
This parameter gives the possibility of enabling or disabling the
temperature monitor for terminal X48/7. The temperature limits
can be set in par. 35-26 and 35-27.
Option:
3
3
[0]
*
[1]
35-26 Term. X48/7 Low Temp. Limit
Range:
Application
dependent
*
35-27 Term. X48/7 High Temp. Limit
Range:
Application
dependent
*
3.21.4 35-3* Temp. Input X48/10 (MCB 114)
35-34 Term. X48/10 Filter Time Constant
Range:
0.001 s
[0.001 -
*
10.000 s]
35-35 Term. X48/10 Temp. Monitor
This parameter gives the possibility of enabling or disabling the
temperature monitor for terminal X48/10. The temperature limits
can be set in pars. 35-36/37.
Option:
[0]
*
[1]
35-36 Term. X48/10 Low Temp. Limit
Range:
Application
dependent
*
158
FC 300 Programming Guide
Function:
Disabled
Enabled
Function:
[Application
Enter the minimum tempera-
dependant]
ture reading that is expected
for normal operation of the
temperature sensor at terminal
X48/7.
Function:
[Application
Enter the maximum tempera-
dependant]
ture reading that is expected
for normal operation of the
temperature sensor at terminal
X48/7.
Function:
Enter the filter time constant. This is a first-
order digital low pass filter time constant
for suppressing electrical noise in terminal
X48/10. A high time constant value
improves dampening but also increases
the time delay through the filter.
Function:
Disabled
Enabled
Function:
[Application
Enter the minimum tempera-
dependant]
ture reading that is expected
for normal operation of the
temperature sensor at terminal
X48/10.
MG.33.M9.02 - VLT
35-37 Term. X48/10 High Temp. Limit
Range:
Application
[Application
dependent
dependant]
*
3.21.5 35-4* Analog Input X48/2 (MCB 114)
35-42 Term. X48/2 Low Current
Range:
4.00
[Application
mA
dependant]
*
35-43 Term. X48/2 High Current
Range:
20.00 mA
[Application
*
dependant]
35-44 Term. X48/2 Low Ref./Feedb. Value
Range:
0.000
[-999999.999 -
*
999999.999 ]
35-45 Term. X48/2 High Ref./Feedb. Value
Range:
100.000
[-999999.999 -
*
999999.999 ]
35-46 Term. X48/2 Filter Time Constant
Range:
0.001 s
[0.001 -
*
10.000 s]
®
is a registered Danfoss trademark
Function:
Enter the maximum tempera-
ture reading that is expected
for normal operation of the
temperature sensor at terminal
X48/10.
Function:
Enter the current (mA) that corresponds
to the low reference value, set in par.
35-44. The value must be set at > 2 mA
in order to activate the Live Zero Time-
out Function in par. 6-01.
Function:
Enter the current (mA) that
corresponds to the high reference
value (set in par. 35-45).
Function:
Enter the reference or feedback
value (in RPM, Hz, bar, etc.) that
corresponds to the voltage or
current set in par. 35-42.
Function:
Enter the reference or feedback
value (in RPM, Hz, bar, etc.) that
corresponds to the voltage or
current set in par. 35-43.
Function:
Enter the filter time constant. This is a first-
order digital low pass filter time constant
for suppressing electrical noise in terminal
X48/2. A high time constant value
improves dampening but also increases
the time delay through the filter.