Parameter Descriptions
2-25 Brake Release Time
Range:
Function:
0.20 s
[0.00 - 5.00
This value defines the time it takes for the
*
s]
mechanical brake to open. This parameter
must act as a time-out when brake
feedback is activated.
2-26 Torque Ref
Range:
Function:
0.00 %
[Application
The value defines the torque applied
*
dependant]
against the closed mechanical brake,
before release
I) Activate brake delay: The frequency converter starts again from the mechanical brake engaged position.
II) Stop delay: When the time between successive starts is shorter than the setting in par. 2-24 Stop Delay, the frequency converter starts
FC 300 Programming Guide
Illustration 3.4: Brake release sequence for hoist mechanical brake control
without applying the mechanical brake (e.g. reversing).
®
MG.33.M9.02 - VLT
is a registered Danfoss trademark
2-27 Torque Ramp Time
Range:
Function:
0.2 s
[0.0 - 5.0 s] The value defines the duration of the torque
*
ramp in clockwise direction.
2-28 Gain Boost Factor
Range:
Function:
1.00
[1.00 - 4.00 ] Only active in flux closed loop. The function
*
ensures a smooth transition from torque
control mode to speed control mode when
the motor takes over the load from the brake.