Parameter Descriptions
3.2.3 0-2* LCP Display
Define the variables displayed in the Graphical Local Control
Panel.
NOTE
Please refer to par. 0-37 Display Text 1, par. 0-38 Display
Text 2 and par. 0-39 Display Text 3 for information on
how to write display texts.
0-20 Display Line 1.1 Small
Option:
Function:
Select a variable for display in line 1,
left position.
[0]
None
No display value selected.
[9]
Performance
Monitor
[37]
Display Text 1
[38]
Display Text 2
[39]
Display Text 3
[748]
PCD Feed Forward
[953]
Profibus Warning
Word
[1005]
Readout Transmit
Error Counter
[1006]
Readout Receive
Error Counter
[1007]
Readout Bus Off
Counter
[1013]
Warning Parame-
ter
[1230]
Warning Parame-
ter
[1472]
Legacy Alarm
Word
[1473]
Legacy Warning
Word
[1474]
Leg. Ext. Status
Word
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
Present control word
[1601]
Reference [Unit]
Total reference (sum of digital/
analog/preset/bus/freeze ref./catch
up and slow-down) in selected unit.
[1602]
Reference %
Total reference (sum of digital/
analog/preset/bus/freeze ref./catch
up and slow-down) in percent.
[1603]
Status Word
Present status word.
[1605]
Main Actual Value
Actual value as a percentage.
[%]
[1609]
Custom Readout
FC 300 Programming Guide
0-20 Display Line 1.1 Small
Option:
[1610]
[1611]
[1612]
[1613]
[1614]
[1615]
[1616]
[1617]
[1618]
[1619]
[1620]
[1621]
[1622]
[1625]
[1630]
[1632]
[1633]
[1634]
[1635]
[1636]
[1637]
[1638]
®
MG.33.M9.02 - VLT
is a registered Danfoss trademark
Function:
Power [kW]
Actual power consumed by the
motor in kW.
Power [hp]
Actual power consumed by the
motor in HP.
Motor Voltage
Voltage supplied to the motor.
Frequency
Motor frequency, i.e. the output
frequency from the frequency
converter in Hz
Motor Current
Phase current of the motor measured
as effective value.
Frequency [%]
Motor frequency, i.e. the output
frequency from the frequency
converter in percent.
Torque [Nm]
Actual motor torque in Nm
Speed [RPM]
Speed in RPM (revolutions per
*
minute) i.e. the motor shaft speed in
closed loop.
Motor Thermal
Thermal load on the motor, calcula-
ted by the ETR function.
KTY sensor
temperature
Motor Angle
Torque [%] High
Res.
Torque [%]
Present motor load as a percentage
of the rated motor torque.
Torque [Nm] High
DC Link Voltage
Intermediate circuit voltage in the
frequency converter.
Brake Energy /s
Present brake power transferred to
an external brake resistor.
Stated as an instantaneous value.
Brake Energy /2
Brake power transferred to an
min
external brake resistor. The mean
power is calculated continuously for
the most recent 120 seconds.
Heatsink Temp.
Present heat sink temperature of the
frequency converter. The cut-out
limit is 95 ±5 oC; cutting back in
occurs at 70 ±5° C.
Inverter Thermal
Percentage load of the inverters.
Inv. Nom. Current
Nominal current of the frequency
converter.
Inv. Max. Current
Maximum current of the frequency
converter.
SL Controller State State of the event executed by the
control.
3
3
27