Parameter Descriptions
13-42 Logic Rule Boolean 2
Array [6]
Option:
[47] Up key
[48] Down key
3
3
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[61] Logic rule 5
[70] SL Time-out 3
[71] SL Time-out 4
[72] SL Time-out 5
[73] SL Time-out 6
[74] SL Time-out 7
[75] Start command given
[76] Digital input x30/2
[77] Digital input x30/3
[78] Digital input x30/4
[79] Digital input x46/1
[80] Digital input x46/3
[81] Digital input x46/5
[82] Digital input x46/7
[83] Digital input x46/9
[84] Digital input x46/11
[85] Digital input x46/13
13-43 Logic Rule Operator 2
Array [6]
Option:
[0]
DISABLED
*
[1]
AND
[2]
OR
[3]
AND NOT
[4]
OR NOT
[5]
NOT AND
[6]
NOT OR
[7]
NOT AND NOT
[8]
NOT OR NOT
130
FC 300 Programming Guide
Function:
Function:
Select the second logical operator to be used
on the boolean input calculated in
par. 13-40 Logic Rule Boolean 1,
par. 13-41 Logic Rule Operator 1, and
par. 13-42 Logic Rule Boolean 2, and the
boolean input coming from par. 13-42 Logic
Rule Boolean 2.
[13-44] signifies the boolean input of
par. 13-44 Logic Rule Boolean 3.
[13-40/13-42] signifies the boolean input
calculated in par. 13-40 Logic Rule Boolean 1,
par. 13-41 Logic Rule Operator 1, and
par. 13-42 Logic Rule Boolean 2. DISABLED [0]
(factory setting). select this option to ignore
par. 13-44 Logic Rule Boolean 3.
MG.33.M9.02 - VLT
13-44 Logic Rule Boolean 3
Array [6]
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10] Out of speed range
[11] Below speed low
[12] Above speed high
[13] Out of feedb. range
[14] Below feedb. low
[15] Above feedb. high
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
[22] Comparator 0
[23] Comparator 1
[24] Comparator 2
[25] Comparator 3
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[30] SL Time-out 0
[31] SL Time-out 1
[32] SL Time-out 2
[33] Digital input DI18
[34] Digital input DI19
[35] Digital input DI27
[36] Digital input DI29
[37] Digital input DI32
[38] Digital input DI33
[39] Start command
[40] Drive stopped
[41] Reset Trip
[42] Auto-reset Trip
[43] Ok key
[44] Reset key
[45] Left key
[46] Right key
®
is a registered Danfoss trademark
Function:
Select the third boolean (TRUE or
FALSE) input for the selected logic
rule. See par. 13-01 ([0] - [61]) and par.
13-02 ([70] - [75]) for further descrip-
tion.